NOVEL · Detector tube selection

GASTEC Active TWA Dosimetric Gas Detector Tube List

Occupational Safety and Environmental Measuring Instruments



GASTEC passive TWA dositubes and clip holder

TWA and Long-Term Gas-Vapour Measurement with GSP Automatic Air Sampling Pump

GASTEC active TWA dosimetric detector tubes are used with the GSP series automatic air sampling pump to draw air samples at a constant flow rate over a specified period to monitor gas or vapour concentrations in workplace and ambient atmospheres. In the list below, chemicals measurable with the same physical tube are grouped under a single tube code, with measurement ranges, shelf life, and package contents presented based on manufacturer data.

GASTEC Active TWA Dosimetric Measurement Tube List – By Tube Code
151TP
Acetone GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Paints/coatings, solvent cleaning, chemical manufacturing, laboratory, and occupational hygiene measurements.
Measurement Range
Acetone (CH₃COCH₃): 25–800 ppm
Shelf Life
27 months (refrigerated storage)
Quantity per Box
10 tubes/box (10 measurements)
191TP
Acrylonitrile GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Acrylic fibres, resin/plastics production, chemical processes, and occupational hygiene measurements.
Measurement Range
Acrylonitrile (CH₂=CHCN): 0.2–12.6 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
3S
Ammonia GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Refrigeration plants, fertiliser/chemical manufacturing, wastewater processes, and ambient air checks.
Measurement Range
Ammonia (NH₃): 0.5–5 ppm
Shelf Life
36 months
Quantity per Box
10 tubes/box (10 measurements)
121P
Benzene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Low-level environmental benzene monitoring, petroleum/fuel sources, and ambient air quality.
Measurement Range
Benzene (C₆H₆): 250–3000 µg/m³
Shelf Life
30 months
Quantity per Box
10 tubes/box (5 measurements)
121TP
Benzene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Occupational hygiene, petrochemicals, solvent processes, and workplace atmosphere benzene measurement.
Measurement Range
Benzene (C₆H₆): 0.1–14.5 ppm
Shelf Life
27 months
Quantity per Box
10 tubes/box (5 measurements)
13TP
Carbon Disulphide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Viscose/cellulose, rubber, chemical manufacturing, and carbon disulphide exposure assessments.
Measurement Range
Carbon Disulphide (CS₂): 0.05–2.4 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
8TP
Chlorine GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Water treatment/disinfection, chemical plants, swimming pools, and low-level chlorine monitoring.
Measurement Range
Chlorine (Cl₂): 0.05–0.6 ppm
Shelf Life
30 months
Quantity per Box
10 tubes/box (10 measurements)
127P
p-Dichlorobenzene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Indoor air quality, chemical products, deodorising products, and environmental monitoring.
Measurement Range
p-Dichlorobenzene (C₆H₄Cl₂): 100–3000 µg/m³
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
183TP
N,N-Dimethylacetamide / N,N-Dimethylformamide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Synthetic fibres, resins, pharmaceutical/chemical production, solvent processes, and occupational exposure measurements.
Measurement Range
N,N-Dimethylacetamide (CH₃CON(CH₃)₂): 3.0–57.5 ppm
N,N-Dimethylformamide (HCON(CH₃)₂): 0.5–30 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (10 measurements)
122P
Ethylbenzene / Toluene / Xylene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Environmental VOC monitoring, paints/coatings, solvent sources, petrochemicals, and indoor/ambient air quality.
Measurement Range
Ethylbenzene (C₆H₅C₂H₅): 110–2750 µg/m³
Toluene (C₆H₅CH₃): 100–7000 µg/m³
Xylene (C₆H₄(CH₃)₂): 540–13500 µg/m³
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
163TPM
Ethylene Oxide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Sterilisation, medical device manufacturing, chemical processes, and ethylene oxide exposure control.
Measurement Range
Ethylene Oxide (C₂H₄O): 1–50 ppm
Shelf Life
12 months (refrigerated storage)
Quantity per Box
10 tubes/box (5 measurements)
163TP
Ethylene Oxide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Low-level ethylene oxide measurement, sterilisation areas, and occupational hygiene applications.
Measurement Range
Ethylene Oxide (C₂H₄O): 0.1–5 ppm
Shelf Life
12 months (refrigerated storage)
Quantity per Box
10 tubes/box (5 measurements)
91P
Formaldehyde GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Indoor air quality, furniture/wood products, laboratory/pathology, and formaldehyde monitoring.
Measurement Range
Formaldehyde (HCHO): 0.02–1.44 ppm
Shelf Life
12 months (refrigerated storage)
Quantity per Box
10 tubes/box (10 measurements)
91PL
Formaldehyde GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Very low-level formaldehyde measurement, indoor air quality, and environmental checks.
Measurement Range
Formaldehyde (HCHO): 0.01–0.80 ppm
Shelf Life
12 months (refrigerated storage)
Quantity per Box
10 tubes/box (10 measurements)
91TP
Formaldehyde GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Occupational hygiene, laboratories, resin/wood processes, and low-concentration formaldehyde measurement.
Measurement Range
Formaldehyde (HCHO): 0.01–1.75 ppm
Shelf Life
12 months (refrigerated storage)
Quantity per Box
10 tubes/box (10 measurements)
102TP
Hexane GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Footwear/adhesives, solvent cleaning, paints, and hexane measurement in petrochemical processes.
Measurement Range
Hexane (C₆H₁₄): 2–80 ppm
Shelf Life
36 months
Quantity per Box
10 tubes/box (10 measurements)
12TP
Hydrogen Cyanide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Electroplating, mining, chemical processes, and HCN exposure/leak assessments.
Measurement Range
Hydrogen Cyanide (HCN): 0.3–9.0 ppm
Shelf Life
12 months
Quantity per Box
10 tubes/box (10 measurements)
17TP
Hydrogen Fluoride GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Acid etching, semiconductor/glass, metal processing, and hydrogen fluoride exposure measurements.
Measurement Range
Hydrogen Fluoride (HF): 0.05–9.0 ppm
Shelf Life
30 months
Quantity per Box
10 tubes/box (10 measurements)
4TP
Hydrogen Sulphide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Wastewater, sewage, oil and gas, pulp and paper, and low-level H₂S monitoring.
Measurement Range
Hydrogen Sulphide (H₂S): 0.1–2.88 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (10 measurements)
4S
Hydrogen Sulphide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Odour complaints, ambient air quality, and very low-level H₂S monitoring.
Measurement Range
Hydrogen Sulphide (H₂S): 10–200 ppb
Shelf Life
18 months (refrigerated storage)
Quantity per Box
10 tubes/box (5 measurements)
113TP
Isopropyl Alcohol GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Disinfectant/cleaning, electronics, printing, paints, and solvent exposure measurements.
Measurement Range
Isopropyl Alcohol (C₃H₈O): 20–400 ppm
Shelf Life
36 months
Quantity per Box
10 tubes/box (10 measurements)
111TP
Methanol GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Chemicals, laboratories, printing/coating, and solvent processes using methanol.
Measurement Range
Methanol (CH₃OH): 20–300 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (10 measurements)
152TP
Methyl Ethyl Ketone GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Paints, adhesives, coatings, printing, and ketone solvent exposure measurements.
Measurement Range
Methyl Ethyl Ketone (CH₃COC₂H₅): 20–300 ppm
Shelf Life
24 months (refrigerated storage)
Quantity per Box
10 tubes/box (10 measurements)
9P
Nitrogen Dioxide GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Combustion sources, traffic/diesel exhaust, indoor air, and low-level environmental NO₂ monitoring.
Measurement Range
Nitrogen Dioxide (NO₂): 0.02–0.20 ppm
Shelf Life
30 months
Quantity per Box
10 tubes/box (10 measurements)
124S
Styrene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Composites/fibreglass, resins, boat manufacturing, and low-level styrene monitoring.
Measurement Range
Styrene (C₈H₈): 0.2–4.0 ppm
Shelf Life
36 months
Quantity per Box
10 tubes/box (5 measurements)
133P
Tetrachloroethylene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Dry cleaning, metal degreasing, and environmental chlorinated solvent monitoring.
Measurement Range
Tetrachloroethylene (C₂Cl₄): 20–720 µg/m³
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
133TP
Tetrachloroethylene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Dry cleaning, metal degreasing, and workplace atmosphere tetrachloroethylene measurement.
Measurement Range
Tetrachloroethylene (C₂Cl₄): 2.5–84 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
122TP
Toluene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Toluene measurement in workplaces using paints, printing, coatings, adhesives, and solvents.
Measurement Range
Toluene (C₇H₈): 2–80 ppm
Shelf Life
36 months
Quantity per Box
10 tubes/box (5 measurements)
132P
Trichloroethylene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Environmental chlorinated solvent monitoring, metal degreasing processes, and ambient/indoor air quality.
Measurement Range
Trichloroethylene (C₂HCl₃): 20–1200 µg/m³
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
132TP
Trichloroethylene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Trichloroethylene measurement in metal degreasing, chemical, and occupational hygiene applications.
Measurement Range
Trichloroethylene (C₂HCl₃): 1–33 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
131P
Vinyl Chloride GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
PVC manufacturing and environmental/low-level vinyl chloride monitoring.
Measurement Range
Vinyl Chloride (C₂H₃Cl): 50–1500 µg/m³
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)
131TP
Vinyl Chloride GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
PVC production, chemical plants, and occupational vinyl chloride exposure measurements.
Measurement Range
Vinyl Chloride (C₂H₃Cl): 0.2–9.6 ppm
Shelf Life
36 months
Quantity per Box
10 tubes/box (10 measurements)
123TP
Xylene GASTEC Active TWA Dosimetric Measurement Tube
Typical Applications
Xylene measurement in paints/coatings, printing, petrochemicals, and solvent processes.
Measurement Range
Xylene (C₈H₁₀): 2–80 ppm
Shelf Life
24 months
Quantity per Box
10 tubes/box (5 measurements)

GASTEC Active TWA Dosimetric Measurement Tubes

Active TWA dosimetric measurement tubes aid in monitoring low or moderate concentrations of gases and vapours by drawing an air sample at a specified flow rate and duration using a GASTEC GSP series automatic air sampling pump. Constant flow sampling ensures a reproducible sample volume in occupational hygiene, personal exposure, indoor air, and environmental air quality studies.

Correct tube selection should be made based on the target chemical, expected concentration, sampling flow rate, and measurement duration. In some P/TP/S series GASTEC tubes, two tubes are used together, so the number of measurements per box may differ from the number of tubes. The current tube data sheet and GSP pump instructions should be checked prior to measurement.

Notice: The technical information, product specifications and images on this page are based on manufacturer publications. The manufacturer may change specifications without notice. For current specifications or assistance in selecting a suitable product for your application, please contact NOVEL at info@novel.com.tr .

NOVEL technical support

For your application,
let us select the right solution together.

Request a Quote from NOVEL ↗

A draft opens in your email client with the subject header of the relevant product or category.