Time-Weighted Average (TWA) Personal Gas and Vapour Exposure Measurement
GASTEC passive TWA dosimetric detector tubes collect gas and vapour exposure in a worker's breathing zone over a defined period using the principle of natural diffusion, without requiring an external sampling pump. On this page, primary chemicals measurable with the same physical tube are grouped under a single tube code; measuring ranges, shelf life, and package contents are presented based on GASTEC manufacturer documentation. You can quickly locate the relevant product by searching by tube code or chemical name.
91D Acetaldehyde / Formaldehyde / Furfural / Methyl Ethyl Ketone GASTEC Passive TWA Dosimetric Detector Tube - Acetaldehyde / Formaldehyde / Furfural / Methyl Ethyl Ketone
Formaldehyde (HCHO): 0.1–20 ppm
Furfural (C₅H₄O₂): 0.3–60 ppm
Methyl Ethyl Ketone (CH₃COC₂H₅): 0.125–25 ppm
151D Acetaldehyde / Acetone / Methyl Ethyl Ketone / Methyl Isobutyl Ketone GASTEC Passive TWA Dosimetric Detector Tube - Acetaldehyde / Acetone / Methyl Ethyl Ketone / Methyl Isobutyl Ketone
Acetone (CH₃COCH₃): 5–1500 ppm
Methyl Ethyl Ketone (CH₃COC₂H₅): 6.5–1950 ppm
Methyl Isobutyl Ketone (C₆H₁₂O): 11.5–3450 ppm
152D Acetaldehyde / Acetone / Methyl Ethyl Ketone / Methyl Isobutyl Ketone GASTEC Passive TWA Dosimetric Detector Tube - Acetaldehyde / Acetone / Methyl Ethyl Ketone / Methyl Isobutyl Ketone
Acetone (CH₃COCH₃): 1.4–420 ppm
Methyl Ethyl Ketone (CH₃COC₂H₅): 2–600 ppm
Methyl Isobutyl Ketone (C₆H₁₂O): 4–1200 ppm
81D Acetic Acid / Acetic Anhydride / Formic Acid GASTEC Passive TWA Dosimetric Detector Tube - Acetic Acid / Acetic Anhydride / Formic Acid
Acetic Anhydride ((CH₃CO)₂O): 0.3–60 ppm
Formic Acid (HCO₂H): 0.55–110 ppm
3D Ammonia / Amines / Hydrazine / Triethylamine GASTEC Passive TWA Dosimetric Detector Tube - Ammonia / Amines / Hydrazine / Triethylamine
3DL Ammonia / Methylamine / Trimethylamine GASTEC Passive TWA Dosimetric Detector Tube - Ammonia / Methylamine / Trimethylamine
122DL Benzene / Toluene / Xylene / Styrene / Ethylbenzene / Cumene GASTEC Passive TWA Dosimetric Detector Tube - Benzene / Toluene / Xylene / Styrene / Ethylbenzene / Cumene
174D 1,3-Butadiene / Ethylene / Isoprene / Vinyl Chloride / trans-1,2-Dichloroethylene GASTEC Passive TWA Dosimetric Detector Tube - 1,3-Butadiene / Ethylene / Isoprene / Vinyl Chloride / trans-1,2-Dichloroethylene
2D Carbon Dioxide GASTEC Passive TWA Dosimeter Tube - Carbon Dioxide
1D Carbon Monoxide GASTEC Passive TWA Dosimeter Tube - Carbon Monoxide
1DL Carbon Monoxide GASTEC Passive TWA Dosimeter Tube - Carbon Monoxide
8D Chlorine GASTEC Passive TWA Dosimeter Tube - Chlorine
132D Chlorine / 1,2-Dichloroethylene / HCl / Tetrachloroethylene / Trichloroethylene GASTEC Passive TWA Dosimeter Tube - Chlorine / 1,2-Dichloroethylene / Hydrogen Chloride / Tetrachloroethylene / Trichloroethylene
112D Ethanol GASTEC Passive TWA Dosimeter Tube - Ethanol
14D Hydrogen Chloride / Hydrogen Fluoride / Nitric Acid GASTEC Passive TWA Dosimeter Tube - Hydrogen Chloride / Hydrogen Fluoride / Nitric Acid
Hydrogen Fluoride (HF): 2.5–250 ppm
Nitric Acid (HNO₃): 0.8–80 ppm
17D Hydrogen Chloride / Hydrogen Fluoride / Nitric Acid GASTEC Passive TWA Dosimeter Tube - Hydrogen Chloride / Hydrogen Fluoride / Nitric Acid
Hydrogen Fluoride (HF): 1–100 ppm
Nitric Acid (HNO₃): 0.32–32 ppm
12D Hydrogen Cyanide GASTEC Passive TWA Dosimeter Tube - Hydrogen Cyanide
32D Hydrogen Peroxide GASTEC Passive TWA Dosimeter Tube - Hydrogen Peroxide
4D Hydrogen Sulphide GASTEC Passive TWA Dosimeter Tube - Hydrogen Sulphide
9D Nitrogen Dioxide GASTEC Passive TWA Dosimeter Tube - Nitrogen Dioxide
9DL Nitrogen Dioxide GASTEC Passive TWA Dosimeter Tube - Nitrogen Dioxide
5DH Sulphur Dioxide GASTEC Passive TWA Dosimeter Tube - Sulphur Dioxide
5D Sulphur Dioxide GASTEC Passive TWA Dosimeter Tube - Sulphur Dioxide
133D Tetrachloroethylene GASTEC Passive TWA Dosimeter Tube - Tetrachloroethylene
GASTEC Passive TWA Dosimeter Tubes
Passive TWA dosimeter tubes are used in occupational hygiene and personal exposure assessments to collect gases or vapours in the worker's breathing zone over a specified period by natural diffusion. Requiring no external gas sampling pump, this method helps determine time-weighted average (TWA) concentrations over a shift or task duration.
Correct tube selection depends on the target chemical, expected concentration, measurement duration, and ambient conditions. Where the same GASTEC tube code can be used for multiple chemicals, the relevant substances are shown on this page under a single tube alongside each chemical's specific measuring range. Checking the current GASTEC product data sheet prior to procurement and application is recommended.