Shelf life is a nominal duration, not the remaining life of the supplied lot. The expiry date and storage conditions on the box take precedence. Storage temperature is separate from measurement temperature. If no refrigeration note is shown here, check the current instructions; absence of a note does not mean refrigeration is unnecessary.

GASTEC Short-Term Gas Detector Tube List – A–Z (By Tube Code)
92
Acetaldehyde GASTEC Short-Term Gas Detector Tube - Acetaldehyde / Diacetyl
Target Chemicals
Acetaldehyde / Diacetyl
Measurement Range
Acetaldehyde: 5–750 ppmDiacetyl: 25–1500 ppm
Number of Pump Strokes
1–4 strokes | Diacetyl: 3 strokes
Shelf Life
36 months
Storage
Refrigerate at 10 °C or below. Source ↗
92M
Acetaldehyde GASTEC Short-Term Gas Detector Tube - Acetaldehyde
Target Chemicals
Acetaldehyde
Measurement Range
Acetaldehyde: 2.5–100 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
24 months
Storage
Refrigerate at 10 °C or below. Source ↗
92L
Acetaldehyde GASTEC Short-Term Gas Detector Tube - Acetaldehyde
Target Chemicals
Acetaldehyde
Measurement Range
Acetaldehyde: 1–20 ppm
Number of Pump Strokes
1 stroke
Shelf Life
24 months
Storage
Refrigerate at 10 °C or below. Source ↗
81
Acetic Acid GASTEC Short-Term Gas Detector Tube - Acetic Acid / Acetic Anhydride / Acrylic Acid / Formic Acid / Isovaleric Acid / Maleic Anhydride / Methacrylic Acid / Propionic Acid
Target Chemicals
Acetic Acid / Acetic Anhydride / Acrylic Acid / Formic Acid / Isovaleric Acid / Maleic Anhydride / Methacrylic Acid / Propionic Acid
Measurement Range
Acetic Acid: 1–100 ppmAcetic Anhydride: 0.6–15 ppmAcrylic Acid: 2–50 ppmFormic Acid: 5.2–130 ppmIsovaleric Acid: 2–50 ppmMaleic Anhydride: 0.8–20 ppmMethacrylic Acid: 1.8–45 ppmPropionic Acid: 3–75 ppm
Number of Pump Strokes
Acetic Acid: 1/2–2 strokes | Acetic Anhydride: 1 stroke | Acrylic Acid: 1 stroke
Shelf Life
36 months
81L
Acetic Acid GASTEC Short-Term Gas Detector Tube - Acetic Acid / Acetic Anhydride / Acrylic Acid / Butyric Acid / Formic Acid / Isovaleric Acid / Methacrylic Acid / Propionic Acid / Valeric Acid
Target Chemicals
Acetic Acid / Acetic Anhydride / Acrylic Acid / Butyric Acid / Formic Acid / Isovaleric Acid / Methacrylic Acid / Propionic Acid / Valeric Acid
Measurement Range
Acetic Acid: 0.125–23 ppmAcetic Anhydride: 0.15–6 ppmAcrylic Acid: 0.45–18 ppmButyric Acid: 0.325–13 ppmFormic Acid: 0.5–20 ppmIsovaleric Acid: 0.38–15 ppmMethacrylic Acid: 0.35–14 ppmPropionic Acid: 0.25–10 ppmValeric Acid: 0.38–15 ppm
Number of Pump Strokes
Acetic Acid: 1/2–2 strokes | Others: 1 stroke
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
151
Acetone GASTEC Short-Term Gas Detector Tube - Acetone / Cyclohexene
Target Chemicals
Acetone / Cyclohexene
Measurement Range
Acetone: 0.05–2.0%Cyclohexene: 0.05–0.8%
Number of Pump Strokes
1–2 strokes | Cyclohexene: 1 stroke
Shelf Life
36 months
151L
Acetone GASTEC Short-Term Gas Detector Tube - Acetone / Methyl Ethyl Ketone / Propionaldehyde
Target Chemicals
Acetone / Methyl Ethyl Ketone / Propionaldehyde
Measurement Range
Acetone: 50–12000 ppmMethyl Ethyl Ketone: 21–1680 ppmPropionaldehyde: 24–1880 ppm
Number of Pump Strokes
1–2 strokes | Methyl Ethyl Ketone: 5 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
12L
Acetone Cyanohydrin GASTEC Short-Term Gas Detector Tube - Acetone Cyanohydrin / Boron Trichloride / Hydrogen Cyanide
Target Chemicals
Acetone Cyanohydrin / Boron Trichloride / Hydrogen Cyanide
Measurement Range
Acetone Cyanohydrin: 2.5–60 ppmBoron Trichloride: 2.25–54 ppmHydrogen Cyanide: 0.5–150 ppm
Number of Pump Strokes
1 stroke | Hydrogen Cyanide: 1/2–5 strokes
Shelf Life
24 months
52
Acetonitrile GASTEC Short-Term Gas Detector Tube - Acetonitrile
Target Chemicals
Acetonitrile
Measurement Range
Acetonitrile: 3–180 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months
171
Acetylene GASTEC Short-Term Gas Detector Tube - Acetylene / Benzene / Ethylene / 1,1,1-Trichloroethane
Target Chemicals
Acetylene / Benzene / Ethylene / 1,1,1-Trichloroethane
Measurement Range
Acetylene: 0.05–4.0%Benzene: 0.03–0.6%Ethylene: 0.1–2.0%1,1,1-Trichloroethane: 0.06–1.2%
Number of Pump Strokes
Acetylene: 1/2–2 strokes | Benzene: 4 strokes | Ethylene: 1 stroke
Shelf Life
36 months
103
Acetylene GASTEC Short-Term Gas Detector Tube - Acetylene / Butane / Ethylene / Heptane / Hexane / Lower-class Hydrocarbons / Isobutane / Isopentane / n-Pentane / Propane
Target Chemicals
Acetylene / Butane / Ethylene / Heptane / Hexane / Lower-class Hydrocarbons / Isobutane / Isopentane / n-Pentane / Propane
Measurement Range
Acetylene: 0.075–3.6%Butane: 0.035–1.68%Ethylene: 0.35–16.8%Heptane: 0.035–1.68%Hexane: 0.025–1.2%Lower-class Hydrocarbons: 0.05–2.4%Isobutane: 0.035–1.68%Isopentane: 0.045–2.16%n-Pentane: 0.0375–1.8%Propane: 0.05–2.4%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
30 months
172
Acetylene GASTEC Short-Term Gas Detector Tube - Acetylene / Ethylene
Target Chemicals
Acetylene / Ethylene
Measurement Range
Acetylene: 32.5–1040 ppmEthylene: 25–1680 ppm
Number of Pump Strokes
1 stroke | Ethylene: 1/2–1 stroke
Shelf Life
36 months
80
Acid Gases GASTEC Short-Term Gas Detector Tube - Acid Gases / Chlorine / Hydrogen Chloride / Iodine / Sulphur Dioxide
Target Chemicals
Acid Gases / Chlorine / Hydrogen Chloride / Iodine / Sulphur Dioxide
Measurement Range
Acid Gases: 1–80 ppmChlorine: 0.7–14 ppmHydrogen Chloride: 8–160 ppmIodine: 0.12–2.4 ppmSulphur Dioxide: 1.5–30 ppm
Number of Pump Strokes
1–4 strokes | Chlorine: 2 strokes
Shelf Life
24 months
93
Acrolein GASTEC Short-Term Gas Detector Tube - Acrolein
Target Chemicals
Acrolein
Measurement Range
Acrolein: 3.3–800 ppm
Number of Pump Strokes
2–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
191
Acrylonitrile GASTEC Short-Term Gas Detector Tube - Acrylonitrile / Propionitrile
Target Chemicals
Acrylonitrile / Propionitrile
Measurement Range
Acrylonitrile: 2–360 ppmPropionitrile: 50–1200 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
191L
Acrylonitrile GASTEC Short-Term Gas Detector Tube - Acrylonitrile / Butyronitrile / 2-Methyl-3-butenenitrile / 2-Pentenenitrile / 3-Pentenenitrile
Target Chemicals
Acrylonitrile / Butyronitrile / 2-Methyl-3-butenenitrile / 2-Pentenenitrile / 3-Pentenenitrile
Measurement Range
Acrylonitrile: 0.1–18 ppmButyronitrile: 6–180 ppm2-Methyl-3-butenenitrile: 0.4–12 ppm2-Pentenenitrile: 0.24–7.2 ppm3-Pentenenitrile: 0.4–12 ppm
Number of Pump Strokes
Acrylonitrile: 1–4 strokes | Butyronitrile: 1 stroke | 2-Methyl-3-butenenitrile: 2 strokes
Shelf Life
36 months
102L
Acrylonitrile GASTEC Short-Term Gas Detector Tube - Acrylonitrile / tert-Butyl Alcohol / Chlorocyclohexane / Cyclohexane / Diisobutyl Ketone / Hexane
Target Chemicals
Acrylonitrile / tert-Butyl Alcohol / Chlorocyclohexane / Cyclohexane / Diisobutyl Ketone / Hexane
Measurement Range
Acrylonitrile: 600–14400 ppmtert-Butyl Alcohol: 500–12000 ppmChlorocyclohexane: 50–1200 ppmCyclohexane: 60–1440 ppmDiisobutyl Ketone: 0.2–1%Hexane: 3.5–1200 ppm
Number of Pump Strokes
1–2 strokes | Cyclohexane: 1 stroke | Hexane: 1–8 strokes
Shelf Life
36 months
140
Aliphatic Hydrocarbons GASTEC Short-Term Gas Detector Tube - Aliphatic Hydrocarbons
Target Chemicals
Aliphatic Hydrocarbons
Measurement Range
Aliphatic Hydrocarbons: 6–3000 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
180
Amines GASTEC Short-Term Gas Detector Tube - Amines / Allylamine / Ammonia / Butylamine / tert-Butylamine / Cyclohexylamine / Di-n-butylamine / Diethylamine / Diethylethanolamine / Diisopropylamine / Dimethylamine / 2-Dimethylaminoethanol / Dimethylaminopropylamine / N,N-Dimethylethylamine / Dipropylamine / Ethanolamine / Ethylamine / Ethylenediamine / N-Ethyl Morpholine / Hexylamine / Isopropylamine / Methylamine / N-Methyl Morpholine / N-Methyl Pyrrolidone / Morpholine / Propylamine / Propylene Imine / Tetramethylenediamine / Triethylamine / Trimethylamine
Target Chemicals
Amines / Allylamine / Ammonia / Butylamine / tert-Butylamine / Cyclohexylamine / Di-n-butylamine / Diethylamine / Diethylethanolamine / Diisopropylamine / Dimethylamine / 2-Dimethylaminoethanol / Dimethylaminopropylamine / N,N-Dimethylethylamine / Dipropylamine / Ethanolamine / Ethylamine / Ethylenediamine / N-Ethyl Morpholine / Hexylamine / Isopropylamine / Methylamine / N-Methyl Morpholine / N-Methyl Pyrrolidone / Morpholine / Propylamine / Propylene Imine / Tetramethylenediamine / Triethylamine / Trimethylamine
Measurement Range
Amines: 5–100 ppmAllylamine: 8.5–170 ppmAmmonia: 1.5–30 ppmButylamine: 8–160 ppmtert-Butylamine: 5.5–110 ppmCyclohexylamine: 7–140 ppmDi-n-butylamine: 5–100 ppmDiethylamine: 5.5–110 ppmDiethylethanolamine: 6–120 ppmDiisopropylamine: 5–100 ppmDimethylamine: 5.5–110 ppm2-Dimethylaminoethanol: 6.5–130 ppmDimethylaminopropylamine: 8–160 ppmN,N-Dimethylethylamine: 4–80 ppmDipropylamine: 4–80 ppmEthanolamine: 7–140 ppmEthylamine: 5–100 ppmEthylenediamine: 14–280 ppmN-Ethyl Morpholine: 5–100 ppmHexylamine: 9–180 ppmIsopropylamine: 5.5–110 ppmMethylamine: 5–100 ppmN-Methylmorpholine: 5–100 ppmN-Methylpyrrolidone: 13.5–270 ppmMorpholine: 9–180 ppmPropylamine: 6–120 ppmPropylene Imine: 5.5–110 ppmTetramethylenediamine: 8.5–170 ppmTriethylamine: 4.5–90 ppmTrimethylamine: 3.5–70 ppm
Number of Pump Strokes
Typically 1 stroke | Ethanolamine: 3 strokes
Shelf Life
36 months
180L
Amines GASTEC Short-Term Gas Detector Tube - Amines / Allylamine / Butylamine / Cyclohexylamine / Di-n-butylamine / Diethylamine / Diethylaminoethanol / Diethylenetriamine / Diisopropylamine / Dimethylamine / 2-Dimethylaminoethanol / Dimethylaminopropylamine / N,N-Dimethylethylamine / Dipropylamine / Ethanolamine / Ethylamine / Ethylenediamine / N-Ethyl Morpholine / Hexamethylenediamine / Hexylamine / Isopropylamine / Methylamine / N-Methyl Morpholine / Morpholine / Pentamethylenediamine / Propylamine / Propylene Imine / Tetramethylenediamine / Triethylamine / Trimethylamine
Target Chemicals
Amines / Allylamine / Butylamine / Cyclohexylamine / Di-n-butylamine / Diethylamine / Diethylaminoethanol / Diethylenetriamine / Diisopropylamine / Dimethylamine / 2-Dimethylaminoethanol / Dimethylaminopropylamine / N,N-Dimethylethylamine / Dipropylamine / Ethanolamine / Ethylamine / Ethylenediamine / N-Ethylmorpholine / Hexamethylenediamine / Hexylamine / Isopropylamine / Methylamine / N-Methylmorpholine / Morpholine / Pentamethylenediamine / Propylamine / Propylene Imine / Tetramethylenediamine / Triethylamine / Trimethylamine
Measurement Range
Amines: 0.5–10 ppmAllylamine: 0.4–8 ppmButylamine: 0.55–11 ppmCyclohexylamine: 0.5–10 ppmDi-n-butylamine: 0.4–8 ppmDiethylamine: 0.45–9 ppmDiethylaminoethanol: 0.6–12 ppmDiethylenetriamine: 0.95–19 ppmDiisopropylamine: 0.3–6 ppmDimethylamine: 0.45–9 ppm2-Dimethylaminoethanol: 0.65–13 ppmDimethylaminopropylamine: 0.6–12 ppmN,N-Dimethylethylamine: 0.3–6 ppmDipropylamine: 0.35–7 ppmEthanolamine: 1.95–39 ppmEthylamine: 0.45–9 ppmEthylenediamine: 0.9–18 ppmN-Ethyl Morpholine: 0.3–6 ppmHexamethylenediamine: 1.55–31 ppmHexylamine: 0.65–13 ppmIsopropylamine: 0.45–9 ppmMethylamine: 0.5–10 ppmN-Methylmorpholine: 0.3–6 ppmMorpholine: 0.5–10 ppmPentamethylenediamine: 0.75–15 ppmPropylamine: 0.5–10 ppmPropylene Imine: 0.35–7 ppmTetramethylenediamine: 0.8–16 ppmTriethylamine: 0.3–6 ppmTrimethylamine: 0.25–5 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months
149
Allyl Isothiocyanate GASTEC Short-Term Gas Detector Tube - Allyl Isothiocyanate / Methyl Methacrylate
Target Chemicals
Allyl Isothiocyanate / Methyl Methacrylate
Measurement Range
Allyl Isothiocyanate: 4.4–88 ppmMethyl Methacrylate: 10–500 ppm
Number of Pump Strokes
2 strokes | Methyl Methacrylate: 1–2 strokes
Shelf Life
24 months
101L
Allyl Chloride GASTEC Short-Term Gas Detector Tube - Allyl Chloride / Gasoline (Petrol) / Heptane / Isobutene
Target Chemicals
Allyl Chloride / Petrol / Heptane / Isobutene
Measurement Range
Allyl Chloride: 0.1–3.4%Petrol: 30–2000 ppmHeptane: 30–2000 ppmIsobutene: 0.07–2.2%
Number of Pump Strokes
1/2 stroke | Petrol: 1–2 strokes | Isobutene: 1 stroke
Shelf Life
36 months
131L
Allyl Chloride GASTEC Short-Term Gas Detector Tube - Allyl Chloride / 1,1,2,2-Tetrachloroethane / Vinyl Chloride
Target Chemicals
Allyl Chloride / 1,1,2,2-Tetrachloroethane / Vinyl Chloride
Measurement Range
Allyl Chloride: 3.2–48 ppm1,1,2,2-Tetrachloroethane: 2–30 ppmVinyl Chloride: 0.1–6.9 ppm
Number of Pump Strokes
2 strokes | Vinyl Chloride: 1–4 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
3H
Ammonia GASTEC Short-Term Gas Detector Tube - Ammonia / Dimethylamine
Target Chemicals
Ammonia / Dimethylamine
Measurement Range
Ammonia: 0.2–32%Dimethylamine: 1.2–19.2%
Number of Pump Strokes
1/2–5 strokes | Dimethylamine: 1 stroke
Shelf Life
36 months
3HM
Ammonia GASTEC Short-Term Gas Detector Tube - Ammonia
Target Chemicals
Ammonia
Measurement Range
Ammonia: 0.05–3.52%
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
3M
Ammonia GASTEC Short-Term Gas Detector Tube - Ammonia / Trimethylamine
Target Chemicals
Ammonia / Trimethylamine
Measurement Range
Ammonia: 10–1000 ppmTrimethylamine: 25–250 ppm
Number of Pump Strokes
1/2–5 strokes | Trimethylamine: 1 stroke
Shelf Life
36 months
3La
Ammonia GASTEC Short-Term Gas Detector Tube - Ammonia
Target Chemicals
Ammonia
Measurement Range
Ammonia: 2.5–220 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
3L
Ammonia GASTEC Short-Term Gas Detector Tube - Ammonia
Target Chemicals
Ammonia
Measurement Range
Ammonia: 0.5–78 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
147
Amyl Acetate GASTEC Short-Term Gas Detector Tube - Amyl Acetate
Target Chemicals
Amyl Acetate
Measurement Range
Amyl Acetate: 10–200 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
181
Aniline GASTEC Short-Term Gas Detector Tube - Aniline / N,N-Dimethylaniline / N-Methyl Aniline / o-Toluidine
Target Chemicals
Aniline / N,N-Dimethylaniline / N-Methylaniline / o-Toluidine
Measurement Range
Aniline: 1.25–60 ppmN,N-Dimethylaniline: 2.5–30 ppmN-Methylaniline: 3.5–42 ppmo-Toluidine: 5–60 ppm
Number of Pump Strokes
2–5 strokes | N,N-Dimethylaniline: 3 strokes | N-Methylaniline: 2 strokes
Shelf Life
36 months
120
Aromatic Hydrocarbons GASTEC Short-Term Gas Detector Tube - Aromatic Hydrocarbons
Target Chemicals
Aromatic Hydrocarbons
Measurement Range
Aromatic Hydrocarbons: 0.4–200 ppm
Number of Pump Strokes
1/2–5 strokes
Shelf Life
36 months
19LA
Arsine GASTEC Short-Term Gas Detector Tube - Arsine
Target Chemicals
Arsine
Measurement Range
Arsine: 0.04–10 ppm
Number of Pump Strokes
1–10 strokes
Shelf Life
27 months
91L
Benzaldehyde GASTEC Short-Term Gas Detector Tube - Benzaldehyde / Cyclohexanone / Diisobutyl Ketone / Formaldehyde / Metaldehyde / Propionaldehyde
Target Chemicals
Benzaldehyde / Cyclohexanone / Diisobutyl Ketone / Formaldehyde / Metaldehyde / Propionaldehyde
Measurement Range
Benzaldehyde: 4–92 ppmCyclohexanone: 10–470 ppmDiisobutyl Ketone: 0.58–29 ppmFormaldehyde: 0.1–45 ppmMetaldehyde: 0.065–3.25 ppmPropionaldehyde: 0.76–38 ppm
Number of Pump Strokes
1 stroke | Cyclohexanone: 1/2 stroke | Diisobutyl Ketone: 4 strokes | Formaldehyde: 1–5 strokes | Metaldehyde: 3 strokes
Shelf Life
36 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
121S
Benzene GASTEC Short-Term Gas Detector Tube - Benzene
Target Chemicals
Benzene
Measurement Range
Benzene: 2–312 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
121
Benzene GASTEC Short-Term Gas Detector Tube - Benzene / Diisobutylene / Alpha-Pinene
Target Chemicals
Benzene / Diisobutylene / Alpha-Pinene
Measurement Range
Benzene: 2.5–120 ppmDiisobutylene: 45–540 ppmAlpha-Pinene: 95–1140 ppm
Number of Pump Strokes
1–4 strokes | Diisobutylene: 1 stroke | Alpha-Pinene: 3 strokes
Shelf Life
36 months
121SL
Benzene GASTEC Short-Term Gas Detector Tube - Benzene
Target Chemicals
Benzene
Measurement Range
Benzene: 1–100 ppm
Number of Pump Strokes
1–5 strokes
Shelf Life
36 months
121SP
Benzene GASTEC Short-Term Gas Detector Tube - Benzene
Target Chemicals
Benzene
Measurement Range
Benzene: 0.2–66 ppm
Number of Pump Strokes
1–3 strokes
Shelf Life
24 months
121L
Benzene GASTEC Short-Term Gas Detector Tube - Benzene / Methylene Iodide / Methyl Iodide
Target Chemicals
Benzene / Methylene Iodide / Methyl Iodide
Measurement Range
Benzene: 0.1–65 ppmMethylene Iodide: 0.22–22 ppmMethyl Iodide: 0.32–32 ppm
Number of Pump Strokes
1–5 strokes
Shelf Life
36 months
136L
Benzyl Bromide GASTEC Short-Term Gas Detector Tube - Benzyl Bromide / Bromoform / n-Butyl Bromide / Chlorobromomethane / 1,1-Dibromoethane / Dibromomethane / Ethyl Bromide / Ethylene Dibromide / Methyl Bromide
Target Chemicals
Benzyl Bromide / Bromoform / n-Butyl Bromide / Chlorobromomethane / 1,1-Dibromoethane / Dibromomethane / Ethyl Bromide / Ethylene Dibromide / Methyl Bromide
Measurement Range
Benzyl Bromide: 11–100 ppmBromoform: 1–50 ppmn-Butyl Bromide: 10–100 ppmChlorobromomethane: 11–110 ppm1,1-Dibromoethane: 7–70 ppmDibromomethane: 5–50 ppmEthyl Bromide: 2.5–200 ppmEthylene Dibromide: 8–80 ppmMethyl Bromide: 2.5–200 ppm
Number of Pump Strokes
1 stroke | Ethyl Bromide: 1/2–4 strokes
Shelf Life
27 months
132L
Benzyl Chloride GASTEC Short-Term Gas Detector Tube - Benzyl Chloride / Trichloroethylene
Target Chemicals
Benzyl Chloride / Trichloroethylene
Measurement Range
Benzyl Chloride: 1.6–20 ppmTrichloroethylene: 0.8–90 ppm
Number of Pump Strokes
2 strokes | Trichloroethylene: 1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
8La
Bromine GASTEC Short-Term Gas Detector Tube - Bromine / Chlorine / Chlorine Dioxide
Target Chemicals
Bromine / Chlorine / Chlorine Dioxide
Measurement Range
Bromine: 0.05–0.8 ppmChlorine: 0.1–16 ppmChlorine Dioxide: 0.3–4.8 ppm
Number of Pump Strokes
Bromine: 4 strokes | Chlorine: 1/2–5 strokes | Chlorine Dioxide: 1 stroke
Shelf Life
36 months
174
1,3-Butadiene GASTEC Short-Term Gas Detector Tube - 1,3-Butadiene / 1,3-Pentadiene
Target Chemicals
1,3-Butadiene / 1,3-Pentadiene
Measurement Range
1,3-Butadiene: 50–800 ppm1,3-Pentadiene: 250–4000 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months
174L
1,3-Butadiene GASTEC Short-Term Gas Detector Tube - 1,3-Butadiene / 1,3-Pentadiene
Target Chemicals
1,3-Butadiene / 1,3-Pentadiene
Measurement Range
1,3-Butadiene: 2.5–100 ppm1,3-Pentadiene: 42.5–850 ppm
Number of Pump Strokes
4–8 strokes | 1,3-Pentadiene: 4 strokes
Shelf Life
36 months
174LL
1,3-Butadiene GASTEC Short-Term Gas Detector Tube - 1,3-Butadiene
Target Chemicals
1,3-Butadiene
Measurement Range
1,3-Butadiene: 0.5–5 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
104
Butane GASTEC Short-Term Gas Detector Tube - Butane / Isobutane / n-Pentane
Target Chemicals
Butane / Isobutane / n-Pentane
Measurement Range
Butane: 25–1400 ppmIsobutane: 55–3080 ppmn-Pentane: 30–1680 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months
114
1-Butanol GASTEC Short-Term Gas Detector Tube - 1-Butanol / 1,2-Dimethoxyethane
Target Chemicals
1-Butanol / 1,2-Dimethoxyethane
Measurement Range
1-Butanol: 10–150 ppm1,2-Dimethoxyethane: 100–1030 ppm
Number of Pump Strokes
3 strokes | 1,2-Dimethoxyethane: 1 stroke
Shelf Life
36 months
115
2-Butanol GASTEC Short-Term Gas Detector Tube - 2-Butanol
Target Chemicals
2-Butanol
Measurement Range
2-Butanol: 5–150 ppm
Number of Pump Strokes
3 strokes
Shelf Life
36 months
142
Butyl Acetate GASTEC Short-Term Gas Detector Tube - Butyl Acetate
Target Chemicals
Butyl Acetate
Measurement Range
Butyl Acetate: 0.05–0.8%
Number of Pump Strokes
2 strokes
Shelf Life
36 months
142L
Butyl Acetate GASTEC Short-Term Gas Detector Tube - Butyl Acetate / Butyl Acrylate / Diethyl Ketone / Isobutyl Acrylate
Target Chemicals
Butyl Acetate / Butyl Acrylate / Diethyl Ketone / Isobutyl Acrylate
Measurement Range
Butyl Acetate: 10–300 ppmButyl Acrylate: 7–210 ppmDiethyl Ketone: 5–513 ppmIsobutyl Acrylate: 5.5–165 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
136H
n-Butyl Bromide GASTEC Short-Term Gas Detector Tube - n-Butyl Bromide / Chlorobromomethane / Ethylene Dibromide / Methyl Bromide
Target Chemicals
n-Butyl Bromide / Chlorobromomethane / Ethylene Dibromide / Methyl Bromide
Measurement Range
n-Butyl Bromide: 24–360 ppmChlorobromomethane: 18–270 ppmEthylene Dibromide: 14–210 ppmMethyl Bromide: 10–600 ppm
Number of Pump Strokes
1 stroke | Methyl Bromide: 1/2–2 strokes
Shelf Life
36 months
136LA
n-Butyl Bromide GASTEC Short-Term Gas Detector Tube - n-Butyl Bromide / Chlorobromomethane / Methyl Bromide / n-Propyl Bromide
Target Chemicals
n-Butyl Bromide / Chlorobromomethane / Methyl Bromide / n-Propyl Bromide
Measurement Range
n-Butyl Bromide: 1–43.2 ppmChlorobromomethane: 0.7–12.6 ppmMethyl Bromide: 1–36 ppmn-Propyl Bromide: 1–18 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
36 months
70L
Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - Butyl Mercaptan / tert-Butyl Mercaptan / Ethyl Mercaptan / Mercaptans / Methyl Mercaptan / Propyl Mercaptan
Target Chemicals
Butyl Mercaptan / tert-Butyl Mercaptan / Ethyl Mercaptan / Mercaptans / Methyl Mercaptan / Propyl Mercaptan
Measurement Range
Butyl Mercaptan: 0.16–12.8 ppmtert-Butyl Mercaptan: 0.1–8 ppmEthyl Mercaptan: 0.1–8 ppmMercaptans: 0.1–8 ppmMethyl Mercaptan: 0.1–8 ppmPropyl Mercaptan: 0.12–9.6 ppm
Number of Pump Strokes
1/2–4 strokes
Shelf Life
24 months
70LN
tert-Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - tert-Butyl Mercaptan / Ethyl Mercaptan / Mercaptans / Methyl Mercaptan / Propyl Mercaptan
Target Chemicals
tert-Butyl Mercaptan / Ethyl Mercaptan / Mercaptans / Methyl Mercaptan / Propyl Mercaptan
Measurement Range
tert-Butyl Mercaptan: 1–40 ppmEthyl Mercaptan: 0.13–10.4 ppmMercaptans: 0.1–8 ppmMethyl Mercaptan: 0.1–8 ppmPropyl Mercaptan: 1–25 ppm
Number of Pump Strokes
1 stroke | Ethyl Mercaptan: 1/2–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
75
tert-Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - tert-Butyl Mercaptan
Target Chemicals
tert-Butyl Mercaptan
Measurement Range
tert-Butyl Mercaptan: 2.5–150 mg/m³
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
75N
tert-Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - tert-Butyl Mercaptan
Target Chemicals
tert-Butyl Mercaptan
Measurement Range
tert-Butyl Mercaptan: 1.25–250 mg/m³
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
75L
tert-Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - tert-Butyl Mercaptan / 2-Mercaptoethanol
Target Chemicals
tert-Butyl Mercaptan / 2-Mercaptoethanol
Measurement Range
tert-Butyl Mercaptan: 0.5–30 mg/m³2-Mercaptoethanol: 0.5–7.5 ppm
Number of Pump Strokes
1/2–2 strokes | 2-Mercaptoethanol: 1 stroke
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
75LN
tert-Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - tert-Butyl Mercaptan
Target Chemicals
tert-Butyl Mercaptan
Measurement Range
tert-Butyl Mercaptan: 0.5–39 mg/m³
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
77
tert-Butyl Mercaptan GASTEC Short-Term Gas Detector Tube - tert-Butyl Mercaptan / Dimethyl Sulfide
Target Chemicals
tert-Butyl Mercaptan / Dimethyl Sulphide
Measurement Range
tert-Butyl Mercaptan: 1–15 mg/m³Dimethyl Sulphide: 1–15 mg/m³
Number of Pump Strokes
1 stroke
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
2HH
Carbon Dioxide GASTEC Short-Term Gas Detector Tube - Carbon Dioxide
Target Chemicals
Carbon Dioxide
Measurement Range
Carbon Dioxide: 2.5–40%
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
2H
Carbon Dioxide GASTEC Short-Term Gas Detector Tube - Carbon Dioxide
Target Chemicals
Carbon Dioxide
Measurement Range
Carbon Dioxide: 0.5–20%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
2L
Carbon Dioxide GASTEC Short-Term Gas Detector Tube - Carbon Dioxide
Target Chemicals
Carbon Dioxide
Measurement Range
Carbon Dioxide: 0.13–6%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
2LL
Carbon Dioxide GASTEC Short-Term Gas Detector Tube - Carbon Dioxide
Target Chemicals
Carbon Dioxide
Measurement Range
Carbon Dioxide: 300–5000 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months
2LC
Carbon Dioxide GASTEC Short-Term Gas Detector Tube - Carbon Dioxide
Target Chemicals
Carbon Dioxide
Measurement Range
Carbon Dioxide: 100–4000 ppm
Number of Pump Strokes
1/2–1 stroke
Shelf Life
24 months
13M
Carbon Disulfide GASTEC Short-Term Gas Detector Tube - Carbon Disulfide
Target Chemicals
Carbon Disulphide
Measurement Range
Carbon Disulphide: 15–5120 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
13
Carbon Disulfide GASTEC Short-Term Gas Detector Tube - Carbon Disulfide
Target Chemicals
Carbon Disulphide
Measurement Range
Carbon Disulphide: 0.63–100 ppm
Number of Pump Strokes
1/2–4 strokes
Shelf Life
36 months
13L
Carbon Disulfide GASTEC Short-Term Gas Detector Tube - Carbon Disulfide
Target Chemicals
Carbon Disulphide
Measurement Range
Carbon Disulphide: 0.1–8.1 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
36 months
1HH
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide
Target Chemicals
Carbon Monoxide
Measurement Range
Carbon Monoxide: 1–50%
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
1H
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide
Target Chemicals
Carbon Monoxide
Measurement Range
Carbon Monoxide: 0.1–10%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
1M
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide / Gasoline (Petrol)
Target Chemicals
Carbon Monoxide / Petrol
Measurement Range
Carbon Monoxide: 0.05–4%Petrol: 0.1–2%
Number of Pump Strokes
1/2–2 strokes | Petrol: 1 stroke
Shelf Life
36 months
1LM
Carbon Monoxide (in Hydrogen) GASTEC Short-Term Gas Detector Tube - Carbon Monoxide (in Hydrogen)
Target Chemicals
Carbon Monoxide (in Hydrogen)
Measurement Range
Carbon Monoxide (in Hydrogen): 25–2000 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
1L
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide
Target Chemicals
Carbon Monoxide
Measurement Range
Carbon Monoxide: 2.5–2000 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
1La
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide
Target Chemicals
Carbon Monoxide
Measurement Range
Carbon Monoxide: 8–1000 ppm
Number of Pump Strokes
1/2–3 strokes
Shelf Life
36 months
1LK
Carbon Monoxide (in Hydrogen) GASTEC Short-Term Gas Detector Tube - Carbon Monoxide (in Hydrogen)
Target Chemicals
Carbon Monoxide (in Hydrogen)
Measurement Range
Carbon Monoxide (in Hydrogen): 5–600 ppm
Number of Pump Strokes
1/2–3 strokes
Shelf Life
36 months
1LKC
Carbon Monoxide (Hydrogen + Hydrocarbons) GASTEC Short-Term Gas Detector Tube - Carbon Monoxide (Hydrogen + Hydrocarbons)
Target Chemicals
Carbon Monoxide (Hydrogen + Hydrocarbons)
Measurement Range
Carbon Monoxide (Hydrogen + Hydrocarbons): 5–100 ppm
Number of Pump Strokes
3 strokes
Shelf Life
36 months
1LL
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide
Target Chemicals
Carbon Monoxide
Measurement Range
Carbon Monoxide: 5–50 ppm
Number of Pump Strokes
2 strokes
Shelf Life
36 months
1LC
Carbon Monoxide GASTEC Short-Term Gas Detector Tube - Carbon Monoxide
Target Chemicals
Carbon Monoxide
Measurement Range
Carbon Monoxide: 1–30 ppm
Number of Pump Strokes
1 stroke
Shelf Life
24 months
134
Carbon Tetrachloride GASTEC Short-Term Gas Detector Tube - Carbon Tetrachloride / Chloropicrin
Target Chemicals
Carbon Tetrachloride / Chloropicrin
Measurement Range
Carbon Tetrachloride: 0.5–60 ppmChloropicrin: 2.5–60 ppm
Number of Pump Strokes
1–5 strokes | Chloropicrin: 1 stroke
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
134L
Carbon Tetrachloride GASTEC Short-Term Gas Detector Tube - Carbon Tetrachloride / Chloropicrin
Target Chemicals
Carbon Tetrachloride / Chloropicrin
Measurement Range
Carbon Tetrachloride: 0.25–11 ppmChloropicrin: 0.28–5.5 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
21
Carbonyl Sulfide GASTEC Short-Term Gas Detector Tube - Carbonyl Sulfide
Target Chemicals
Carbonyl Sulphide
Measurement Range
Carbonyl Sulphide: 5–200 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
21LA
Carbonyl Sulfide GASTEC Short-Term Gas Detector Tube - Carbonyl Sulfide
Target Chemicals
Carbonyl Sulphide
Measurement Range
Carbonyl Sulphide: 2–125 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
8HH
Chlorine GASTEC Short-Term Gas Detector Tube - Chlorine / Hydrogen Chloride
Target Chemicals
Chlorine / Hydrogen Chloride
Measurement Range
Chlorine: 0.25–10%Hydrogen Chloride: 1.5–30%
Number of Pump Strokes
1/2–1 stroke | Hydrogen Chloride: 1/2 stroke
Shelf Life
36 months
8H
Chlorine GASTEC Short-Term Gas Detector Tube - Chlorine / Chlorine Dioxide
Target Chemicals
Chlorine / Chlorine Dioxide
Measurement Range
Chlorine: 25–1000 ppmChlorine Dioxide: 45–450 ppm
Number of Pump Strokes
1/2–2 strokes | Chlorine Dioxide: 1 stroke
Shelf Life
36 months
8LL
Chlorine GASTEC Short-Term Gas Detector Tube - Chlorine
Target Chemicals
Chlorine
Measurement Range
Chlorine: 0.025–2 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
23M
Chlorine Dioxide GASTEC Short-Term Gas Detector Tube - Chlorine Dioxide
Target Chemicals
Chlorine Dioxide
Measurement Range
Chlorine Dioxide: 0.1–10 ppm
Number of Pump Strokes
1/2–5 strokes
Shelf Life
36 months
23L
Chlorine Dioxide GASTEC Short-Term Gas Detector Tube - Chlorine Dioxide
Target Chemicals
Chlorine Dioxide
Measurement Range
Chlorine Dioxide: 0.025–1.2 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
126
Chlorobenzene GASTEC Short-Term Gas Detector Tube - Chlorobenzene
Target Chemicals
Chlorobenzene
Measurement Range
Chlorobenzene: 2–500 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
126L
Chlorobenzene GASTEC Short-Term Gas Detector Tube - Chlorobenzene
Target Chemicals
Chlorobenzene
Measurement Range
Chlorobenzene: 0.5–57 ppm
Number of Pump Strokes
1–3 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
135
Chlorobromomethane GASTEC Short-Term Gas Detector Tube - Chlorobromomethane / 1,1-Dichloroethane / Ethylene Dichloride / 1,1,1-Trichloroethane / 1,1,2-Trichloroethane
Target Chemicals
Chlorobromomethane / 1,1-Dichloroethane / Ethylene Dichloride / 1,1,1-Trichloroethane / 1,1,2-Trichloroethane
Measurement Range
Chlorobromomethane: 22–110 ppm1,1-Dichloroethane: 90–450 ppmEthylene Dichloride: 400–2000 ppm1,1,1-Trichloroethane: 100–2000 ppm1,1,2-Trichloroethane: 220–750 ppm
Number of Pump Strokes
1 stroke | 1,1,1-Trichloroethane: 1/2–1 stroke | 1,1,2-Trichloroethane: 2 strokes
Shelf Life
36 months
51H
Chlorodifluoromethane (R22) GASTEC Short-Term Gas Detector Tube - Chlorodifluoromethane (R22) / Dichlorodifluoromethane (R12) / 1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114) / Halothane / R112 (1,1,2,2-Tetrachloro-1,2-difluoroethane) / R11 (Trichlorofluoromethane) / R113 (1,1,2-Trichloro-1,2,2-trifluoroethane) / R113a (1,1,1-Trichloro-2,2,2-trifluoroethane)
Target Chemicals
Chlorodifluoromethane (R22) / Dichlorodifluoromethane (R12) / 1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114) / Halothane / R112 (1,1,2,2-Tetrachloro-1,2-difluoroethane) / R11 (Trichlorofluoromethane) / R113 (1,1,2-Trichloro-1,2,2-trifluoroethane) / R113a (1,1,1-Trichloro-2,2,2-trifluoroethane)
Measurement Range
Chlorodifluoromethane (R22): 0.1–2.4% (with Pyrotec No. 840)Dichlorodifluoromethane (R12): 325–7800 ppm (with Pyrotec No. 840)1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114): 475–11400 ppm (with Pyrotec No. 840)Halothane: 800–6400 ppmR112 (1,1,2,2-Tetrachloro-1,2-difluoroethane): 125–3000 ppmR11 (Trichlorofluoromethane): 275–6600 ppmR113 (1,1,2-Trichloro-1,2,2-trifluoroethane): 250–6000 ppmR113a (1,1,1-Trichloro-2,2,2-trifluoroethane): 200–4800 ppm
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
51
Chlorodifluoromethane (R22) GASTEC Short-Term Gas Detector Tube - Chlorodifluoromethane (R22) / 2-Chloro-1,1,1,2-tetrafluoroethane (R124) / Dichlorodifluoromethane (R12) / 1,1-Dichloro-1-fluoroethane (R141b) / Dichloropentafluoropropane (R225) / 1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114) / 2,2-Dichloro-1,1,1-trifluoroethane (R123) / Enflurane / Halothane / Methyl Chloride / R112 (1,1,2,2-Tetrachloro-1,2-difluoroethane) / R11 (Trichlorofluoromethane) / R113 (1,1,2-Trichloro-1,2,2-trifluoroethane) / R113a (1,1,1-Trichloro-2,2,2-trifluoroethane)
Target Chemicals
Chlorodifluoromethane (R22) / 2-Chloro-1,1,1,2-tetrafluoroethane (R124) / Dichlorodifluoromethane (R12) / 1,1-Dichloro-1-fluoroethane (R141b) / Dichloropentafluoropropane (R225) / 1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114) / 2,2-Dichloro-1,1,1-trifluoroethane (R123) / Enflurane / Halothane / Methyl Chloride / R112 (1,1,2,2-Tetrachloro-1,2-difluoroethane) / R11 (Trichlorofluoromethane) / R113 (1,1,2-Trichloro-1,2,2-trifluoroethane) / R113a (1,1,1-Trichloro-2,2,2-trifluoroethane)
Measurement Range
Chlorodifluoromethane (R22): 25–1000 ppm (with Pyrotec No.840)2-Chloro-1,1,1,2-tetrafluoroethane (R124): 45–1800 ppm (with Pyrotec No.840)Dichlorodifluoromethane (R12): 11–440 ppm (with Pyrotec No.840)1,1-Dichloro-1-fluoroethane (R141b): 10–1000 ppm (with Pyrotec No.840)Dichloropentafluoropropane (R225): 20–800 ppm (with Pyrotec No.840)1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114): 20–800 ppm (with Pyrotec No.840)2,2-Dichloro-1,1,1-trifluoroethane (R123): 14–1600 ppm (with Pyrotec No.840)Enflurane: 110–1230 ppm (with Pyrotec No.840)Halothane: 24–960 ppmMethyl Chloride: 12–480 ppmR112 (1,1,2,2-Tetrachloro-1,2-difluoroethane): 7–280 ppmR11 (Trichlorofluoromethane): 8–320 ppmR113 (1,1,2-Trichloro-1,2,2-trifluoroethane): 10–400 ppmR113a (1,1,1-Trichloro-2,2,2-trifluoroethane): 10–400 ppm
Number of Pump Strokes
1 stroke | 1,1-Dichloro-1-fluoroethane (R141b): 1/2–1 stroke
Shelf Life
36 months
51L
Chlorodifluoromethane (R22) GASTEC Short-Term Gas Detector Tube - Chlorodifluoromethane (R22) / Dichlorodifluoromethane (R12) / 1,1-Dichloro-1-fluoroethane (R141b) / Dichloropentafluoropropane (R225) / 1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114) / 2,2-Dichloro-1,1,1-trifluoroethane (R123) / Enflurane / Halothane / Methyl Chloride / Methylene Chloride / R112 (1,1,2,2-Tetrachloro-1,2-difluoroethane) / R11 (Trichlorofluoromethane) / R113 (1,1,2-Trichloro-1,2,2-trifluoroethane) / R113a (1,1,1-Trichloro-2,2,2-trifluoroethane)
Target Chemicals
Chlorodifluoromethane (R22) / Dichlorodifluoromethane (R12) / 1,1-Dichloro-1-fluoroethane (R141b) / Dichloropentafluoropropane (R225) / 1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114) / 2,2-Dichloro-1,1,1-trifluoroethane (R123) / Enflurane / Halothane / Methyl Chloride / Methylene Chloride / R112 (1,1,2,2-Tetrachloro-1,2-difluoroethane) / R11 (Trichlorofluoromethane) / R113 (1,1,2-Trichloro-1,2,2-trifluoroethane) / R113a (1,1,1-Trichloro-2,2,2-trifluoroethane)
Measurement Range
Chlorodifluoromethane (R22): 2.5–135 ppm (with Pyrotec No.840)Dichlorodifluoromethane (R12): 1.8–97.2 ppm (with Pyrotec No.840)1,1-Dichloro-1-fluoroethane (R141b): 1.1–22 ppm (with Pyrotec No.840)Dichloropentafluoropropane (R225): 1.4–28 ppm (with Pyrotec No.840)1,2-Dichloro-1,1,2,2-tetrafluoroethane (R114): 1.8–97.2 ppm (with Pyrotec No.840)2,2-Dichloro-1,1,1-trifluoroethane (R123): 1.4–28 ppm (with Pyrotec No.840)Enflurane: 25–145 ppm (with Pyrotec No.840)Halothane: 3–60 ppmMethyl Chloride: 1.6–86.4 ppmMethylene Chloride: 1–54 ppmR112 (1,1,2,2-Tetrachloro-1,2-difluoroethane): 1–54 ppmR11 (Trichlorofluoromethane): 0.8–43.2 ppmR113 (1,1,2-Trichloro-1,2,2-trifluoroethane): 1–54 ppmR113a (1,1,1-Trichloro-2,2,2-trifluoroethane): 0.8–43.2 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
36 months
137
Chloroform GASTEC Direct Reading Detector Tube - Chloroform
Target Chemicals
Chloroform
Measurement Range
Chloroform: 4–400 ppm
Number of Pump Strokes
3–7 strokes
Shelf Life
36 months
137LA
Chloroform GASTEC Direct Reading Detector Tube - Chloroform
Target Chemicals
Chloroform
Measurement Range
Chloroform: 0.5–30 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
137LL
Chloroform GASTEC Direct Reading Detector Tube - Chloroform
Target Chemicals
Chloroform
Measurement Range
Chloroform: 0.3–4.5 ppm
Number of Pump Strokes
4 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
233
Chloropicrin GASTEC Direct Reading Detector Tube - Chloropicrin
Target Chemicals
Chloropicrin
Measurement Range
Chloropicrin: 0.045–22 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
12 months
61
m-Cresol GASTEC Direct Reading Detector Tube - m-Cresol / o-Cresol / p-Cresol
Target Chemicals
m-Cresol / o-Cresol / p-Cresol
Measurement Range
m-Cresol: 1–25 ppmo-Cresol: 0.35–67.5 ppmp-Cresol: 1–25 ppm
Number of Pump Strokes
2 strokes | o-Cresol: 1–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
122L
Cumene GASTEC Direct Reading Detector Tube - Cumene / Diethylbenzene / Ethylbenzene / Toluene / Xylene
Target Chemicals
Cumene / Diethylbenzene / Ethylbenzene / Toluene / Xylene
Measurement Range
Cumene: 2–100 ppmDiethylbenzene: 2–150 ppmEthylbenzene: 1–70 ppmToluene: 1–100 ppmXylene: 2–200 ppm
Number of Pump Strokes
2 strokes | Diethylbenzene: 4 strokes | Toluene: 1–4 strokes
Shelf Life
36 months
102H
Cyclohexane GASTEC Direct Reading Detector Tube - Cyclohexane / Hexane / Methylcyclohexane
Target Chemicals
Cyclohexane / Hexane / Methylcyclohexane
Measurement Range
Cyclohexane: 0.015–1.2%Hexane: 0.015–1.2%Methylcyclohexane: 0.04–0.84%
Number of Pump Strokes
1/2–2 strokes | Methylcyclohexane: 1 stroke
Shelf Life
36 months
118
Cyclohexanol GASTEC Direct Reading Detector Tube - Cyclohexanol
Target Chemicals
Cyclohexanol
Measurement Range
Cyclohexanol: 5–100 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
154
Cyclohexanone GASTEC Direct Reading Detector Tube - Cyclohexanone / Diacetone Alcohol / Furfural / Isophorone
Target Chemicals
Cyclohexanone / Diacetone Alcohol / Furfural / Isophorone
Measurement Range
Cyclohexanone: 2–72 ppmDiacetone Alcohol: 2–100 ppmFurfural: 2–30 ppmIsophorone: 2–30 ppm
Number of Pump Strokes
2–4 strokes | Diacetone Alcohol: 2 strokes | Isophorone: 8 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
141L
Cymene GASTEC Direct Reading Detector Tube - Cymene / Diisopropylbenzene / Ethyl Acetate / Ethyl Acrylate / 2-Hexanol / Isopropyl Ether / Mesityl Oxide / Methyl Acrylate / Methyl Isothiocyanate
Target Chemicals
Cymene / Diisopropylbenzene / Ethyl Acetate / Ethyl Acrylate / 2-Hexanol / Isopropyl Ether / Mesityl Oxide / Methyl Acrylate / Methyl Isothiocyanate
Measurement Range
Cymene: 2.4–96 ppmDiisopropylbenzene: 16–108 ppmEthyl Acetate: 20–800 ppmEthyl Acrylate: 8.4–336 ppm2-Hexanol: 168–1680 ppmIsopropyl Ether: 17.6–704 ppmMesityl Oxide: 72–1080 ppmMethyl Acrylate: 7.2–288 ppmMethyl Isothiocyanate: 5.4–216 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
105
n-Decane GASTEC Direct Reading Detector Tube - n-Decane / Heptane / Hexane / Higher-class Hydrocarbons / Nonane / Octane
Target Chemicals
n-Decane / Heptane / Hexane / Higher Hydrocarbons / Nonane / Octane
Measurement Range
n-Decane: 200–6000 ppmHeptane: 90–2700 ppmHexane: 80–2400 ppmHigher Hydrocarbons: 100–3000 ppmNonane: 130–3900 ppmOctane: 100–3000 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
36 months
22
Diborane GASTEC Direct Reading Detector Tube - Diborane
Target Chemicals
Diborane
Measurement Range
Diborane: 0.02–5 ppm
Number of Pump Strokes
1–5 strokes
Shelf Life
24 months
127
m-Dichlorobenzene GASTEC Direct Reading Detector Tube - m-Dichlorobenzene / o-Dichlorobenzene / p-Dichlorobenzene
Target Chemicals
m-Dichlorobenzene / o-Dichlorobenzene / p-Dichlorobenzene
Measurement Range
m-Dichlorobenzene: 2.5–300 ppmo-Dichlorobenzene: 2.5–300 ppmp-Dichlorobenzene: 2.5–300 ppm
Number of Pump Strokes
2 strokes
Shelf Life
36 months
139
1,2-Dichloroethylene GASTEC Direct Reading Detector Tube - 1,2-Dichloroethylene
Target Chemicals
1,2-Dichloroethylene
Measurement Range
1,2-Dichloroethylene: 5–250 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
132HA
1,2-Dichloroethylene GASTEC Direct Reading Detector Tube - 1,2-Dichloroethylene / 1,3-Dichloropropene / Trichloroethylene
Target Chemicals
1,2-Dichloroethylene / 1,3-Dichloropropene / Trichloroethylene
Measurement Range
1,2-Dichloroethylene: 80–800 ppm1,3-Dichloropropene: 45–450 ppmTrichloroethylene: 20–1300 ppm
Number of Pump Strokes
1 stroke | 1,3-Dichloropropene: 2 strokes | Trichloroethylene: 1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
132LL
1,2-Dichloroethylene GASTEC Direct Reading Detector Tube - 1,2-Dichloroethylene / Dichlorvos / Trichloroethylene
Target Chemicals
1,2-Dichloroethylene / Dichlorvos / Trichloroethylene
Measurement Range
1,2-Dichloroethylene: 0.375–6 ppmDichlorvos: 0.11–1.8 ppmTrichloroethylene: 0.125–8.8 ppm
Number of Pump Strokes
1 stroke | Dichlorvos: 2 strokes | Trichloroethylene: 1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
131La
1,3-Dichloropropene GASTEC Direct Reading Detector Tube - 1,3-Dichloropropene / p-Ethylbenzyl Chloride / Ethyl Chloroformate / 2-Methylallyl Chloride / Methyl Chloroformate / Propylene Dichloride / 1,2,4-Trichlorobenzene / Vinyl Chloride
Target Chemicals
1,3-Dichloropropene / p-Ethylbenzyl Chloride / Ethyl Chloroformate / 2-Methylallyl Chloride / Methyl Chloroformate / Propylene Dichloride / 1,2,4-Trichlorobenzene / Vinyl Chloride
Measurement Range
1,3-Dichloropropene: 0.5–10 ppmp-Ethylbenzyl Chloride: 2.5–50 ppmEthyl Chloroformate: 7–140 ppm2-Methylallyl Chloride: 2.8–55 ppmMethyl Chloroformate: 58–1160 ppmPropylene Dichloride: 40–800 ppm1,2,4-Trichlorobenzene: 0.65–13 ppmVinyl Chloride: 0.25–54 ppm
Number of Pump Strokes
2 strokes | 2-Methylallyl Chloride: 1 stroke | Methyl Chloroformate: 5 strokes | 1,2,4-Trichlorobenzene: 4 strokes | Vinyl Chloride: 1/2–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
184
N,N-Dimethylacetamide GASTEC Direct Reading Detector Tube - N,N-Dimethylacetamide
Target Chemicals
N,N-Dimethylacetamide
Measurement Range
N,N-Dimethylacetamide: 1.5–240 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
53
Dimethyl Disulfide GASTEC Direct Reading Detector Tube - Dimethyl Disulfide / Dimethyl Sulfide
Target Chemicals
Dimethyl Disulfide / Dimethyl Sulfide
Measurement Range
Dimethyl Disulfide: 0.3–6 ppm (with Pyrotec)Dimethyl Sulphide: 0.15–10 ppm (with Pyrotec)
Number of Pump Strokes
3 strokes | Dimethyl Sulfide: 3–5 strokes
Shelf Life
24 months
183
N,N-Dimethylformamide GASTEC Direct Reading Detector Tube - N,N-Dimethylformamide
Target Chemicals
N,N-Dimethylformamide
Measurement Range
N,N-Dimethylformamide: 0.8–90 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
185
Dimethylhydrazine GASTEC Direct Reading Detector Tube - Dimethylhydrazine / Hydrazine / Methyl Hydrazine
Target Chemicals
Dimethylhydrazine / Hydrazine / Methyl Hydrazine
Measurement Range
Dimethylhydrazine: 0.1–2 ppmHydrazine: 0.04–2 ppmMethyl Hydrazine: 0.6–12 ppm
Number of Pump Strokes
5 strokes | Hydrazine: 5–10 strokes
Shelf Life
36 months
159
1,4-Dioxane GASTEC Direct Reading Detector Tube - 1,4-Dioxane / Tetrahydrofuran
Target Chemicals
1,4-Dioxane / Tetrahydrofuran
Measurement Range
1,4-Dioxane: 25–144 ppmTetrahydrofuran: 25–800 ppm
Number of Pump Strokes
2 strokes | Tetrahydrofuran: 1–2 strokes
Shelf Life
36 months
163
1,4-Dioxane GASTEC Direct Reading Detector Tube - 1,4-Dioxane / Ethylene Oxide / Propylene Oxide
Target Chemicals
1,4-Dioxane / Ethylene Oxide / Propylene Oxide
Measurement Range
1,4-Dioxane: 0.1–6.0%Ethylene Oxide: 0.05–3.0%Propylene Oxide: 0.065–3.9%
Number of Pump Strokes
1 stroke
Shelf Life
36 months
124L
Divinylbenzene GASTEC Direct Reading Detector Tube - Divinylbenzene / Styrene
Target Chemicals
Divinylbenzene / Styrene
Measurement Range
Divinylbenzene: 1–15 ppmStyrene: 2–100 ppm
Number of Pump Strokes
3 strokes | Styrene: 1–4 strokes
Shelf Life
36 months
113L
Divinylmethoxysilane GASTEC Direct Reading Detector Tube - Divinyl Methoxysilane / Ethylene Glycol Monobutyl Ether / Ethylene Glycol Monoethyl Ether / Ethylene Glycol Monomethyl Ether / Isopropyl Alcohol / 2-Methoxyethyl Acetate / Propyl Alcohol / Vinyl Trimethoxysilane
Target Chemicals
Divinyl Methoxysilane / Ethylene Glycol Monobutyl Ether / Ethylene Glycol Monoethyl Ether / Ethylene Glycol Monomethyl Ether / Isopropyl Alcohol / 2-Methoxyethyl Acetate / Propyl Alcohol / Vinyl Trimethoxysilane
Measurement Range
Divinyl Methoxysilane: 6.5–25 ppmEthylene Glycol Monobutyl Ether: 200–1000 ppmEthylene Glycol Monoethyl Ether: 110–1000 ppmEthylene Glycol Monomethyl Ether: 75–760 ppmIsopropyl Alcohol: 20–800 ppm2-Methoxyethyl Acetate: 300–1300 ppmPropyl Alcohol: 130–560 ppmVinyl Trimethoxysilane: 6.5–25 ppm
Number of Pump Strokes
2 strokes | Isopropyl Alcohol: 1–2 strokes | Propyl Alcohol: 1 stroke
Shelf Life
36 months
163L
Epichlorohydrin GASTEC Direct Reading Detector Tube - Epichlorohydrin / Ethylene Oxide / Propylene Oxide
Target Chemicals
Epichlorohydrin / Ethylene Oxide / Propylene Oxide
Measurement Range
Epichlorohydrin: 1.2–120 ppmEthylene Oxide: 0.4–550 ppmPropylene Oxide: 1–100 ppm
Number of Pump Strokes
2 strokes | Ethylene Oxide: 1–4 strokes | Propylene Oxide: 1 stroke
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
112
Ethanol GASTEC Direct Reading Detector Tube - Ethanol
Target Chemicals
Ethanol
Measurement Range
Ethanol: 0.01–7.5%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
112L
Ethanol GASTEC Direct Reading Detector Tube - Ethanol
Target Chemicals
Ethanol
Measurement Range
Ethanol: 50–2000 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
36 months
141
Ethyl Acetate GASTEC Direct Reading Detector Tube - Ethyl Acetate / Vinyl Acetate
Target Chemicals
Ethyl Acetate / Vinyl Acetate
Measurement Range
Ethyl Acetate: 0.1–1.5%Vinyl Acetate: 0.06–0.9%
Number of Pump Strokes
1 stroke
Shelf Life
36 months
122
Ethylbenzene GASTEC Direct Reading Detector Tube - Ethylbenzene / Toluene
Target Chemicals
Ethylbenzene / Toluene
Measurement Range
Ethylbenzene: 11–330 ppmToluene: 5–690 ppm
Number of Pump Strokes
1 stroke | Toluene: 1/2–2 strokes
Shelf Life
36 months
138
Ethyl Chloride GASTEC Direct Reading Detector Tube - Ethyl Chloride / Methylene Chloride
Target Chemicals
Ethyl Chloride / Methylene Chloride
Measurement Range
Ethyl Chloride: 15–150 ppmMethylene Chloride: 30–500 ppm
Number of Pump Strokes
1 stroke | Methylene Chloride: 1–2 strokes
Shelf Life
36 months
172L
Ethylene GASTEC Direct Reading Detector Tube - Ethylene
Target Chemicals
Ethylene
Measurement Range
Ethylene: 0.2–100 ppm
Number of Pump Strokes
2–4 strokes
Shelf Life
36 months
111L
Ethylene Chlorohydrin GASTEC Direct Reading Detector Tube - Ethylene Chlorohydrin / Methanol
Target Chemicals
Ethylene Chlorohydrin / Methanol
Measurement Range
Ethylene Chlorohydrin: 80–200 ppmMethanol: 20–1000 ppm
Number of Pump Strokes
3 strokes | Methanol: 1–2 strokes
Shelf Life
24 months | Methanol: 36 months
232
Ethylene Dichloride GASTEC Direct Reading Detector Tube - Ethylene Dichloride
Target Chemicals
Ethylene Dichloride
Measurement Range
Ethylene Dichloride: 1–39 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
135L
Ethylene Dichloride GASTEC Direct Reading Detector Tube - Ethylene Dichloride / 1,1,2,2-Tetrabromoethane / 1,1,1-Trichloroethane / 1,2,3-Trichloropropane
Target Chemicals
Ethylene Dichloride / 1,1,2,2-Tetrabromoethane / 1,1,1-Trichloroethane / 1,2,3-Trichloropropane
Measurement Range
Ethylene Dichloride: 104–1040 ppm1,1,2,2-Tetrabromoethane: 0.92–9.2 ppm1,1,1-Trichloroethane: 6–900 ppm1,2,3-Trichloropropane: 36–360 ppm
Number of Pump Strokes
1 stroke | 1,1,2,2-Tetrabromoethane: 4 strokes | 1,1,1-Trichloroethane: 1/2–2 strokes
Shelf Life
27 months
165L
Ethylene Glycol GASTEC Direct Reading Detector Tube - Ethylene Glycol
Target Chemicals
Ethylene Glycol
Measurement Range
Ethylene Glycol: 10–100 mg/m³
Number of Pump Strokes
2 strokes
Shelf Life
36 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
113LL
Ethylene Glycol Monobutyl Ether GASTEC Direct Reading Detector Tube - Ethylene Glycol Monobutyl Ether / Ethylene Glycol Monoethyl Ether / Ethylene Glycol Monomethyl Ether / Isopropyl Alcohol / 1-Methoxy-2-propanol / Propyl Alcohol
Target Chemicals
Ethylene Glycol Monobutyl Ether / Ethylene Glycol Monoethyl Ether / Ethylene Glycol Monomethyl Ether / Isopropyl Alcohol / 1-Methoxy-2-propanol / Propyl Alcohol
Measurement Range
Ethylene Glycol Monobutyl Ether: 60–400 ppmEthylene Glycol Monoethyl Ether: 46–460 ppmEthylene Glycol Monomethyl Ether: 44–440 ppmIsopropyl Alcohol: 20–460 ppm1-Methoxy-2-propanol: 26–260 ppmPropyl Alcohol: 55–170 ppm
Number of Pump Strokes
2 strokes | Isopropyl Alcohol: 1–2 strokes
Shelf Life
24 months
163LL
Ethylene Oxide GASTEC Direct Reading Detector Tube - Ethylene Oxide
Target Chemicals
Ethylene Oxide
Measurement Range
Ethylene Oxide: 0.1–10 ppm
Number of Pump Strokes
2–4 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
161
Ethyl Ether GASTEC Direct Reading Detector Tube - Ethyl Ether / Isopropyl Ether / Methyl Ether / Tetrahydrofuran / Toluene
Target Chemicals
Ethyl Ether / Isopropyl Ether / Methyl Ether / Tetrahydrofuran / Toluene
Measurement Range
Ethyl Ether: 0.04–1.0%Isopropyl Ether: 0.018–0.45%Methyl Ether: 0.034–0.85%Tetrahydrofuran: 0.056–1.4%Toluene: 0.02–0.8%
Number of Pump Strokes
1 stroke | Isopropyl Ether: 2 strokes
Shelf Life
36 months
161L
Ethyl Ether GASTEC Direct Reading Detector Tube - Ethyl Ether
Target Chemicals
Ethyl Ether
Measurement Range
Ethyl Ether: 10–1120 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
24 months
72
Ethyl Mercaptan GASTEC Direct Reading Detector Tube - Ethyl Mercaptan
Target Chemicals
Ethyl Mercaptan
Measurement Range
Ethyl Mercaptan: 0.5–120 ppm
Number of Pump Strokes
1–10 strokes
Shelf Life
36 months
72L
Ethyl Mercaptan GASTEC Direct Reading Detector Tube - Ethyl Mercaptan
Target Chemicals
Ethyl Mercaptan
Measurement Range
Ethyl Mercaptan: 0.2–75 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
72LN
Ethyl Mercaptan GASTEC Direct Reading Detector Tube - Ethyl Mercaptan
Target Chemicals
Ethyl Mercaptan
Measurement Range
Ethyl Mercaptan: 0.15–57.5 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
70
Ethyl Mercaptan GASTEC Direct Reading Detector Tube - Ethyl Mercaptan / Isopropyl Mercaptan / Mercaptans / Methyl Mercaptan / Propyl Mercaptan
Target Chemicals
Ethyl Mercaptan / Isopropyl Mercaptan / Mercaptans / Methyl Mercaptan / Propyl Mercaptan
Measurement Range
Ethyl Mercaptan: 0.5–120 ppmIsopropyl Mercaptan: 10–240 ppmMercaptans: 0.5–120 ppmMethyl Mercaptan: 0.35–84 ppmPropyl Mercaptan: 22.5–540 ppm
Number of Pump Strokes
1–10 strokes | Isopropyl Mercaptan: 1 stroke
Shelf Life
36 months
71H
Ethyl Mercaptan GASTEC Direct Reading Detector Tube - Ethyl Mercaptan / Methyl Mercaptan
Target Chemicals
Ethyl Mercaptan / Methyl Mercaptan
Measurement Range
Ethyl Mercaptan: 100–3800 ppmMethyl Mercaptan: 20–2700 ppm
Number of Pump Strokes
1 stroke | Methyl Mercaptan: 1/2–2 strokes
Shelf Life
36 months
17
Fluorine GASTEC Direct Reading Detector Tube - Fluorine / Hydrogen Fluoride
Target Chemicals
Fluorine / Hydrogen Fluoride
Measurement Range
Fluorine: 0.5–50 ppmHydrogen Fluoride: 0.25–100 ppm
Number of Pump Strokes
1 stroke | Hydrogen Fluoride: 1–7 strokes
Shelf Life
36 months
91M
Formaldehyde GASTEC Direct Reading Detector Tube - Formaldehyde
Target Chemicals
Formaldehyde
Measurement Range
Formaldehyde: 8–6400 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
91
Formaldehyde GASTEC Direct Reading Detector Tube - Formaldehyde
Target Chemicals
Formaldehyde
Measurement Range
Formaldehyde: 2–100 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
91LL
Formaldehyde GASTEC Direct Reading Detector Tube - Formaldehyde
Target Chemicals
Formaldehyde
Measurement Range
Formaldehyde: 0.05–1 ppm
Number of Pump Strokes
5 strokes
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
101
Petrol GASTEC Direct Reading Detector Tube - Gasoline (Petrol) / Heptane / Isooctane / Octane
Target Chemicals
Petrol / Heptane / Isooctane / Octane
Measurement Range
Petrol: 0.015–1.2%Heptane: 0.015–1.2%Isooctane: 0.027–0.54%Octane: 0.036–0.72%
Number of Pump Strokes
1/2–2 strokes | Isooctane: 1 stroke
Shelf Life
36 months
30
Hydrogen GASTEC Direct Reading Detector Tube - Hydrogen
Target Chemicals
Hydrogen
Measurement Range
Hydrogen: 0.5–2%
Number of Pump Strokes
1 stroke
Shelf Life
36 months
15L
Hydrogen Bromide GASTEC Direct Reading Detector Tube - Hydrogen Bromide / Trichloroacetic Acid
Target Chemicals
Hydrogen Bromide / Trichloroacetic Acid
Measurement Range
Hydrogen Bromide: 0.8–16 ppmTrichloroacetic Acid: 1–37 ppm
Number of Pump Strokes
1 stroke
Shelf Life
36 months
14R
Hydrogen Chloride GASTEC Direct Reading Detector Tube - Hydrogen Chloride
Target Chemicals
Hydrogen Chloride
Measurement Range
Hydrogen Chloride: 50–5000 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
14M
Hydrogen Chloride GASTEC Direct Reading Detector Tube - Hydrogen Chloride
Target Chemicals
Hydrogen Chloride
Measurement Range
Hydrogen Chloride: 10–1000 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
14L
Hydrogen Chloride GASTEC Direct Reading Detector Tube - Hydrogen Chloride
Target Chemicals
Hydrogen Chloride
Measurement Range
Hydrogen Chloride: 0.2–76 ppm
Number of Pump Strokes
1/2–5 strokes
Shelf Life
36 months
12H
Hydrogen Cyanide GASTEC Direct Reading Detector Tube - Hydrogen Cyanide
Target Chemicals
Hydrogen Cyanide
Measurement Range
Hydrogen Cyanide: 0.05–1.6%
Number of Pump Strokes
1 stroke
Shelf Life
36 months
12M
Hydrogen Cyanide GASTEC Direct Reading Detector Tube - Hydrogen Cyanide
Target Chemicals
Hydrogen Cyanide
Measurement Range
Hydrogen Cyanide: 17–2400 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
12LL
Hydrogen Cyanide GASTEC Direct Reading Detector Tube - Hydrogen Cyanide
Target Chemicals
Hydrogen Cyanide
Measurement Range
Hydrogen Cyanide: 0.2–10 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
24 months
17L
Hydrogen Fluoride GASTEC Direct Reading Detector Tube - Hydrogen Fluoride
Target Chemicals
Hydrogen Fluoride
Measurement Range
Hydrogen Fluoride: 0.09–72 ppm
Number of Pump Strokes
1–5 strokes
Shelf Life
30 months
17LL
Hydrogen Fluoride GASTEC Direct Reading Detector Tube - Hydrogen Fluoride
Target Chemicals
Hydrogen Fluoride
Measurement Range
Hydrogen Fluoride: 0.05–24 ppm
Number of Pump Strokes
1–5 strokes
Shelf Life
24 months
32
Hydrogen Peroxide GASTEC Direct Reading Detector Tube - Hydrogen Peroxide
Target Chemicals
Hydrogen Peroxide
Measurement Range
Hydrogen Peroxide: 0.5–10 ppm
Number of Pump Strokes
5 strokes
Shelf Life
36 months
4HT
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 1–40%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
4HP
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 0.25–20%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
4HH
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 0.1–4%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
4H
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 10–4000 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
4HM
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 25–1600 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
4M
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 12.5–500 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
4L
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 1–240 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
4LL
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 0.25–120 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
4LK
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 1–40 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
4LB
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 0.5–12 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
4LT
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide
Target Chemicals
Hydrogen Sulphide
Measurement Range
Hydrogen Sulphide: 0.05–4 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
45S
Hydrogen Sulphide GASTEC Direct Reading Detector Tube - Hydrogen Sulphide / Sulphur Dioxide (Separate Determination) / Sulphur Dioxide (Separate Determination with H₂S)
Target Chemicals
Hydrogen Sulphide / Sulphur Dioxide (separate determination) / Sulphur Dioxide (separate determination with H₂S)
Measurement Range
Hydrogen Sulphide / Sulphur Dioxide (separate determination): H₂S: 1.25–120 ppm; separate determination with SO₂Sulphur Dioxide (separate determination with H₂S): 0.25–20 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
45H
Hydrogen Sulphide + Sulphur Dioxide (Total) GASTEC Direct Reading Detector Tube - Hydrogen Sulphide + Sulphur Dioxide (Total) / Sulphur Dioxide + Hydrogen Sulphide (Total)
Target Chemicals
Hydrogen Sulphide + Sulphur Dioxide (total) / Sulphur Dioxide + Hydrogen Sulphide (total)
Measurement Range
Hydrogen Sulphide + Sulphur Dioxide (total): 0.02–8.0%Sulphur Dioxide + Hydrogen Sulphide (total): 0.02–8.0%
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
9L
Iodine GASTEC Direct-Reading Gas Detector Tube - Iodine
Target Chemicals
Iodine
Measurement Range
Iodine: 0.2–12 ppm
Number of Pump Strokes
2 strokes
Shelf Life
36 months
148
Isoamyl Acetate GASTEC Direct-Reading Gas Detector Tube - Isoamyl Acetate
Target Chemicals
Isoamyl Acetate
Measurement Range
Isoamyl Acetate: 10–200 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
117
Isoamyl Alcohol GASTEC Direct-Reading Gas Detector Tube - Isoamyl Alcohol
Target Chemicals
Isoamyl Alcohol
Measurement Range
Isoamyl Alcohol: 5–300 ppm
Number of Pump Strokes
2 strokes
Shelf Life
36 months
144
Isobutyl Acetate GASTEC Direct-Reading Gas Detector Tube - Isobutyl Acetate
Target Chemicals
Isobutyl Acetate
Measurement Range
Isobutyl Acetate: 10–300 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
116
Isobutyl Alcohol GASTEC Direct-Reading Gas Detector Tube - Isobutyl Alcohol
Target Chemicals
Isobutyl Alcohol
Measurement Range
Isobutyl Alcohol: 3.7–150 ppm
Number of Pump Strokes
2–4 strokes
Shelf Life
36 months
146
Isopropyl Acetate GASTEC Direct-Reading Gas Detector Tube - Isopropyl Acetate
Target Chemicals
Isopropyl Acetate
Measurement Range
Isopropyl Acetate: 10–500 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
113
Isopropyl Alcohol GASTEC Direct-Reading Gas Detector Tube - Isopropyl Alcohol / Propyl Alcohol
Target Chemicals
Isopropyl Alcohol / Propyl Alcohol
Measurement Range
Isopropyl Alcohol: 0.02–5.0%Propyl Alcohol: 0.04–2.5%
Number of Pump Strokes
1/2–2 strokes | Propyl Alcohol: 1 stroke
Shelf Life
36 months
100A
LPG GASTEC Direct-Reading Gas Detector Tube - LPG / Propylene / Xylene
Target Chemicals
LPG / Propylene / Xylene
Measurement Range
LPG: 0.02–0.8%Propylene: 0.02–0.8%Xylene: 0.1–1.2%
Number of Pump Strokes
1 stroke | Xylene: 2 strokes
Shelf Life
36 months
40
Mercury Vapour GASTEC Direct-Reading Gas Detector Tube - Mercury Vapour
Target Chemicals
Mercury Vapour
Measurement Range
Mercury Vapour: 0.05–13.2 mg/m³
Number of Pump Strokes
1/2–5 strokes
Shelf Life
36 months
192
Methacrylonitrile GASTEC Direct-Reading Gas Detector Tube - Methacrylonitrile
Target Chemicals
Methacrylonitrile
Measurement Range
Methacrylonitrile: 0.2–32 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
111
Methanol GASTEC Direct-Reading Gas Detector Tube - Methanol
Target Chemicals
Methanol
Measurement Range
Methanol: 0.002–6.0%
Number of Pump Strokes
1/2–4 strokes
Shelf Life
36 months
111LL
Methanol GASTEC Direct-Reading Gas Detector Tube - Methanol
Target Chemicals
Methanol
Measurement Range
Methanol: 2–62 ppm
Number of Pump Strokes
2–4 strokes
Shelf Life
24 months
136LL
Methyl Bromide GASTEC Direct-Reading Gas Detector Tube - Methyl Bromide
Target Chemicals
Methyl Bromide
Measurement Range
Methyl Bromide: 0.1–3.0 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
24 months
166
Methyl tert-Butyl Ether GASTEC Direct-Reading Gas Detector Tube - Methyl tert-Butyl Ether / Methyl Isothiocyanate
Target Chemicals
Methyl tert-Butyl Ether / Methyl Isothiocyanate
Measurement Range
Methyl tert-Butyl Ether: 10–660 ppmMethyl Isothiocyanate: 39.8–1766 ppm
Number of Pump Strokes
1–2 strokes | Methyl Isothiocyanate: 1/2–1 stroke
Shelf Life
24 months
119
Methylcyclohexanol GASTEC Direct-Reading Gas Detector Tube - Methylcyclohexanol
Target Chemicals
Methylcyclohexanol
Measurement Range
Methylcyclohexanol: 5–100 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
155
Methylcyclohexanone GASTEC Direct-Reading Gas Detector Tube - Methylcyclohexanone
Target Chemicals
Methylcyclohexanone
Measurement Range
Methylcyclohexanone: 2–80 ppm
Number of Pump Strokes
2–3 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
138L
Methylene Chloride GASTEC Direct-Reading Gas Detector Tube - Methylene Chloride
Target Chemicals
Methylene Chloride
Measurement Range
Methylene Chloride: 4–150 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
24 months
152
Methyl Ethyl Ketone GASTEC Direct-Reading Gas Detector Tube - Methyl Ethyl Ketone
Target Chemicals
Methyl Ethyl Ketone
Measurement Range
Methyl Ethyl Ketone: 0.02–0.6%
Number of Pump Strokes
2 strokes
Shelf Life
36 months
152L
Methyl Ethyl Ketone GASTEC Direct-Reading Gas Detector Tube - Methyl Ethyl Ketone
Target Chemicals
Methyl Ethyl Ketone
Measurement Range
Methyl Ethyl Ketone: 10–384 ppm
Number of Pump Strokes
1/2–1 stroke
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
230H
Methyl Iodide GASTEC Direct-Reading Gas Detector Tube - Methyl Iodide
Target Chemicals
Methyl Iodide
Measurement Range
Methyl Iodide: 100–34800 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
230
Methyl Iodide GASTEC Direct-Reading Gas Detector Tube - Methyl Iodide
Target Chemicals
Methyl Iodide
Measurement Range
Methyl Iodide: 0.5–108 ppm
Number of Pump Strokes
1/2–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerated storage required. Follow the temperature instruction on the box and current manufacturer instructions. Source ↗
153
Methyl Isobutyl Ketone GASTEC Direct-Reading Gas Detector Tube - Methyl Isobutyl Ketone / Styrene
Target Chemicals
Methyl Isobutyl Ketone / Styrene
Measurement Range
Methyl Isobutyl Ketone: 0.05–0.6%Styrene: 0.15–2.3%
Number of Pump Strokes
2 strokes
Shelf Life
36 months
153L
Methyl Isobutyl Ketone GASTEC Direct-Reading Gas Detector Tube - Methyl Isobutyl Ketone
Target Chemicals
Methyl Isobutyl Ketone
Measurement Range
Methyl Isobutyl Ketone: 2.5–130 ppm
Number of Pump Strokes
1/2–1 stroke
Shelf Life
12 months
234L
Methyl Isothiocyanate GASTEC Direct-Reading Gas Detector Tube - Methyl Isothiocyanate
Target Chemicals
Methyl Isothiocyanate
Measurement Range
Methyl Isothiocyanate: 0.07–25 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months
71
Methyl Mercaptan GASTEC Direct-Reading Gas Detector Tube - Methyl Mercaptan
Target Chemicals
Methyl Mercaptan
Measurement Range
Methyl Mercaptan: 0.25–140 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
182
4-Methylpyridine GASTEC Direct-Reading Gas Detector Tube - 4-Methylpyridine / Pyridine
Target Chemicals
4-Methylpyridine / Pyridine
Measurement Range
4-Methylpyridine: 0.38–10.5 ppmPyridine: 0.2–36.4 ppm
Number of Pump Strokes
1 stroke | Pyridine: 1/2–2 strokes
Shelf Life
36 months
60
Naphthalene GASTEC Direct-Reading Gas Detector Tube - Naphthalene / Phenol
Target Chemicals
Naphthalene / Phenol
Measurement Range
Naphthalene: 0.5–14 ppmPhenol: 0.12–183 ppm
Number of Pump Strokes
2 strokes | Phenol: 1/2–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
31B
Oxygen GASTEC Direct-Reading Gas Detector Tube - Oxygen
Target Chemicals
Oxygen
Measurement Range
Oxygen: 3–24%
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
18M
Ozone GASTEC Direct-Reading Gas Detector Tube - Ozone
Target Chemicals
Ozone
Measurement Range
Ozone: 4–400 ppm
Number of Pump Strokes
1/2–5 strokes
Shelf Life
36 months
18L
Ozone GASTEC Direct-Reading Gas Detector Tube - Ozone
Target Chemicals
Ozone
Measurement Range
Ozone: 0.025–6 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
133L
Pentachloroethane GASTEC Direct-Reading Gas Detector Tube - Pentachloroethane / Tetrachloroethylene
Target Chemicals
Pentachloroethane / Tetrachloroethylene
Measurement Range
Pentachloroethane: 40–500 ppmTetrachloroethylene: 1–75 ppm
Number of Pump Strokes
1 stroke | Tetrachloroethylene: 1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
193
2-Pentenenitrile GASTEC Direct-Reading Gas Detector Tube - 2-Pentenenitrile
Target Chemicals
2-Pentenenitrile
Measurement Range
2-Pentenenitrile: 0.5–15 ppm
Number of Pump Strokes
2–4 strokes
Shelf Life
36 months
106
Petroleum Benzine GASTEC Direct-Reading Gas Detector Tube - Petroleum Benzine / Petroleum Ether / Petroleum Naphtha
Target Chemicals
Petroleum Benzine / Petroleum Ether / Petroleum Naphtha
Measurement Range
Petroleum Benzine / Petroleum Ether / Petroleum Naphtha: 0.5–28 mg/L
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
16
Phosgene GASTEC Direct-Reading Gas Detector Tube - Phosgene
Target Chemicals
Phosgene
Measurement Range
Phosgene: 0.05–20 ppm
Number of Pump Strokes
1–10 strokes
Shelf Life
18 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
7H
Phosphine GASTEC Direct-Reading Gas Detector Tube - Phosphine
Target Chemicals
Phosphine
Measurement Range
Phosphine: 200–5500 ppm
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
7J
Phosphine GASTEC Direct-Reading Gas Detector Tube - Phosphine
Target Chemicals
Phosphine
Measurement Range
Phosphine: 2.5–1000 ppm
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
7
Phosphine GASTEC Direct-Reading Gas Detector Tube - Phosphine
Target Chemicals
Phosphine
Measurement Range
Phosphine: 2.5–100 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
7L
Phosphine GASTEC Direct-Reading Gas Detector Tube - Phosphine
Target Chemicals
Phosphine
Measurement Range
Phosphine: 0.15–5 ppm
Number of Pump Strokes
5–10 strokes
Shelf Life
36 months
7LA
Phosphine GASTEC Direct-Reading Gas Detector Tube - Phosphine
Target Chemicals
Phosphine
Measurement Range
Phosphine: 0.05–9.8 ppm
Number of Pump Strokes
1–10 strokes
Shelf Life
24 months
145
Propyl Acetate GASTEC Direct-Reading Gas Detector Tube - Propyl Acetate
Target Chemicals
Propyl Acetate
Measurement Range
Propyl Acetate: 20–500 ppm
Number of Pump Strokes
2 strokes
Shelf Life
24 months
128
Stoddard Solvent GASTEC Direct-Reading Gas Detector Tube - Stoddard Solvent
Target Chemicals
Stoddard Solvent
Measurement Range
Stoddard Solvent: 50–8000 mg/m³
Number of Pump Strokes
1 stroke
Shelf Life
36 months
124
Styrene GASTEC Direct-Reading Gas Detector Tube - Styrene
Target Chemicals
Styrene
Measurement Range
Styrene: 10–1500 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
5H
Sulphur Dioxide GASTEC Direct-Reading Gas Detector Tube - Sulphur Dioxide
Target Chemicals
Sulphur Dioxide
Measurement Range
Sulphur Dioxide: 0.05–8%
Number of Pump Strokes
1/2–10 strokes
Shelf Life
36 months
5M
Sulphur Dioxide GASTEC Direct-Reading Gas Detector Tube - Sulphur Dioxide
Target Chemicals
Sulphur Dioxide
Measurement Range
Sulphur Dioxide: 20–3600 ppm
Number of Pump Strokes
1/2–4 strokes
Shelf Life
36 months
5L
Sulphur Dioxide GASTEC Direct-Reading Gas Detector Tube - Sulphur Dioxide
Target Chemicals
Sulphur Dioxide
Measurement Range
Sulphur Dioxide: 1.25–200 ppm
Number of Pump Strokes
1/2–4 strokes
Shelf Life
36 months
5La
Sulphur Dioxide GASTEC Direct-Reading Gas Detector Tube - Sulphur Dioxide / Thionyl Chloride
Target Chemicals
Sulphur Dioxide / Thionyl Chloride
Measurement Range
Sulphur Dioxide: 0.5–60 ppmThionyl Chloride: 1.44–21.6 ppm
Number of Pump Strokes
1–8 strokes | Thionyl Chloride: 2 strokes
Shelf Life
36 months
5LC
Sulphur Dioxide GASTEC Direct-Reading Gas Detector Tube - Sulphur Dioxide
Target Chemicals
Sulphur Dioxide
Measurement Range
Sulphur Dioxide: 0.1–22 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
5Lb
Sulphur Dioxide GASTEC Direct-Reading Gas Detector Tube - Sulphur Dioxide
Target Chemicals
Sulphur Dioxide
Measurement Range
Sulphur Dioxide: 0.05–10 ppm
Number of Pump Strokes
1–8 strokes
Shelf Life
36 months
35
Sulphuric Acid GASTEC Direct-Reading Gas Detector Tube - Sulphuric Acid
Target Chemicals
Sulphuric Acid
Measurement Range
Sulphuric Acid: 0.5–5 mg/m³
Number of Pump Strokes
5 strokes
Shelf Life
24 months
133HA
Tetrachloroethylene GASTEC Direct-Reading Gas Detector Tube - Tetrachloroethylene
Target Chemicals
Tetrachloroethylene
Measurement Range
Tetrachloroethylene: 7–900 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
133M
Tetrachloroethylene GASTEC Direct-Reading Gas Detector Tube - Tetrachloroethylene
Target Chemicals
Tetrachloroethylene
Measurement Range
Tetrachloroethylene: 2–220 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
133LL
Tetrachloroethylene GASTEC Direct-Reading Gas Detector Tube - Tetrachloroethylene
Target Chemicals
Tetrachloroethylene
Measurement Range
Tetrachloroethylene: 0.1–6.6 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
132HH
Trichloroethylene GASTEC Direct-Reading Gas Detector Tube - Trichloroethylene
Target Chemicals
Trichloroethylene
Measurement Range
Trichloroethylene: 0.05–2.5%
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
159L
Tetrahydrofuran GASTEC Direct-Reading Gas Detector Tube - Tetrahydrofuran
Target Chemicals
Tetrahydrofuran
Measurement Range
Tetrahydrofuran: 5–232 ppm
Number of Pump Strokes
1/2–1 stroke
Shelf Life
12 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
76H
Tetrahydrothiophene GASTEC Direct-Reading Gas Detector Tube - Tetrahydrothiophene
Target Chemicals
Tetrahydrothiophene
Measurement Range
Tetrahydrothiophene: 10–200 ppm
Number of Pump Strokes
1 stroke
Shelf Life
24 months
76
Tetrahydrothiophene GASTEC Direct-Reading Gas Detector Tube - Tetrahydrothiophene
Target Chemicals
Tetrahydrothiophene
Measurement Range
Tetrahydrothiophene: 1–10 ppm
Number of Pump Strokes
4 strokes
Shelf Life
24 months
76M
Tetrahydrothiophene GASTEC Direct-Reading Gas Detector Tube - Tetrahydrothiophene
Target Chemicals
Tetrahydrothiophene
Measurement Range
Tetrahydrothiophene: 10–100 mg/m³
Number of Pump Strokes
2 strokes
Shelf Life
24 months
132M
Trichloroethylene GASTEC Direct-Reading Gas Detector Tube - Trichloroethylene
Target Chemicals
Trichloroethylene
Measurement Range
Trichloroethylene: 2–270 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
30 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
123
Trimethylbenzene GASTEC Direct-Reading Gas Detector Tube - Trimethylbenzene / Xylene
Target Chemicals
Trimethylbenzene / Xylene
Measurement Range
Trimethylbenzene: 10–300 ppmXylene: 5–625 ppm
Number of Pump Strokes
2 strokes | Xylene: 1/2–2 strokes
Shelf Life
36 months
143
Vinyl Acetate GASTEC Direct-Reading Gas Detector Tube - Vinyl Acetate
Target Chemicals
Vinyl Acetate
Measurement Range
Vinyl Acetate: 5–250 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
36 months
131
Vinyl Chloride GASTEC Direct-Reading Gas Detector Tube - Vinyl Chloride
Target Chemicals
Vinyl Chloride
Measurement Range
Vinyl Chloride: 0.025–2%
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
131LB
Vinyl Chloride GASTEC Direct-Reading Gas Detector Tube - Vinyl Chloride
Target Chemicals
Vinyl Chloride
Measurement Range
Vinyl Chloride: 0.4–70 ppm
Number of Pump Strokes
1–4 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
130L
Vinylidene Chloride GASTEC Direct-Reading Gas Detector Tube - Vinylidene Chloride
Target Chemicals
Vinylidene Chloride
Measurement Range
Vinylidene Chloride: 0.4–40.6 ppm
Number of Pump Strokes
1/2–2 strokes
Shelf Life
24 months (refrigerated storage)
Storage
Refrigerate at 10 °C or below. Source ↗
6
Water Vapour GASTEC Direct-Reading Gas Detector Tube - Water Vapour
Target Chemicals
Water Vapour
Measurement Range
Water Vapour: 0.5–32 mg/L
Number of Pump Strokes
1/2–2 strokes
Shelf Life
36 months
6L
Water Vapour GASTEC Direct-Reading Gas Detector Tube - Water Vapour
Target Chemicals
Water Vapour
Measurement Range
Water Vapour: 0.05–2 mg/L
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
6LP
Pipeline Dew Point GASTEC Direct-Reading Gas Detector Tube - Pipeline Dew Point
Target Chemicals
Pipeline Dew Point
Measurement Range
Pipeline Dew Point: 3–100 lb/MMCF
Number of Pump Strokes
1/2–1 stroke
Shelf Life
36 months
6LLP
Pipeline Dew Point GASTEC Direct-Reading Gas Detector Tube - Pipeline Dew Point
Target Chemicals
Pipeline Dew Point
Measurement Range
Pipeline Dew Point: 2–10 lb/MMCF
Number of Pump Strokes
2 strokes
Shelf Life
36 months
123L
Xylene GASTEC Direct-Reading Gas Detector Tube - Xylene
Target Chemicals
Xylene
Measurement Range
Xylene: 2–200 ppm
Number of Pump Strokes
1–2 strokes
Shelf Life
36 months

GASTEC Direct-Reading Gas Detector Tubes

GASTEC direct-reading detector tubes are used in conjunction with a GASTEC manual direct-reading gas sampling pump to rapidly determine the concentration of target gases or vapours on site based on the colour-change principle. Appropriate tube selection must be made according to the target chemical, expected concentration, and the number of pump strokes specified in the catalogue.

Notice: The technical information, product specifications and images on this page are based on manufacturer publications. The manufacturer may change specifications without notice. For current specifications or assistance in selecting a suitable product for your application, please contact NOVEL at info@novel.com.tr .

NOVEL technical support

For your application,
let us select the right solution together.

Request a Quote from NOVEL ↗

A draft opens in your email client with the subject header of the relevant product or category.