Customer need
Converting collected mass to airborne concentration requires the sampling flow to be known.
NOVEL · Products and system solutions

Primary volumetric flow measurement from 1 mL/min to 30 L/min using three interchangeable wet cells. Select low, standard or high-flow sets for sampling-pump checks.
Request a Quote from NOVEL ↗From need to solution
Gilian Gilibrator-2 USB Air Flow Calibrator: selection starts with the measurement or system output your team needs for its decision.
Converting collected mass to airborne concentration requires the sampling flow to be known.
A flow calibrator provides a measurement for checking the assembled sampling train and comparing pump settings.
Record pre- and post-sampling checks and select a calibrator for the required flow range, connections and uncertainty.
| Cell | Flow range | Cell part number | 230 V / European set |
|---|---|---|---|
| Low | 1–250 mL/min | 800267-1 | 800272-2 |
| Standard | 20 mL/min–6 L/min | 800266-1 | 800271-2 |
| High | 2–30 L/min | 800265-1 | 800270-2 |
Standard European three-cell kit: 801804-1. Low and standard cells: ±1% of reading or ±0.001 L/min, whichever is greater; high cell: ±1% of reading. Specifications follow the manufacturer’s 2021 USB datasheet.
Check flow with the pump, selected sampler and media assembled. Choose a cell covering the target flow and record pre- and post-sampling values.
The instrument times a soap bubble through a known cell volume. Keep the cell upright and stable, and use the specified manufacturer soap solution.
USB and RS-232 interfaces, rechargeable operation and approximately 8 hours battery life. Stated operating temperature is 5–35 °C.
| Part number | Item and purpose |
|---|---|
| 850190-1-R | Gilibrator-2 USB control base |
| 800450 | Gilibrator soap solution |
| 400667 | Soap solution dispenser |
| 811-9943-01-R | USB cable |
| 780-0015-05-R | SmartCal software |
| 811-0507-01-R / 811-0509-01-R | Charger / power adapter |
| 800844-5-230 | 230 V Deluxe kit including optional pump diagnostic panel |
The diagnostic panel is not included in every standard set. Confirm cells, connections, power supply and calibration-certificate scope with your quotation.