Customer need
Voltage-presence checks and inadvertent-approach warnings serve different purposes depending on the task and device.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

Worn on the wrist, this auxiliary alarm supports worker awareness by emitting an audible warning when approaching an energised line. Switchgear/cubicle work and lower voltage detection require different model selection.
HXW-6W: AC 1–42 kV. HXW-6WL: AC 400 V–22 kV.
Request a Quote from NOVEL ↗From need to solution
Hasegawa HXW-6W and HXW-6WL Wrist-Type Proximity Alarm: selection starts with the measurement or system output your team needs for its decision.
Voltage-presence checks and inadvertent-approach warnings serve different purposes depending on the task and device.
The selected model’s detection and warning function provides supplementary information within the manufacturer’s specified operating conditions.
Select the correct model and procedure; an approach alarm does not replace absence-of-voltage verification, protective equipment or electrical-safety procedures.
This auxiliary alarm is not used to verify de-energised status. It does not replace isolation, lock-out/tag-out, suitable PPE, or the facility's electrical safety procedures. Detection direction, nearby grounded structures, and site conditions may alter the alarm distance; verification in the operating environment is required.

| Operating voltage | AC 1–42 kV · 50/60 Hz |
|---|---|
| Theoretical alarm distances | 6.6 kV → 0.6 m; 11 kV → 0.8 m; 22 kV → 1.1 m; 33 kV → 1.3 m |
| Battery | 1 × CR1620 · continuous operation approx. 15 hours; approx. 10 months when unused |
| Sound level | At least 65 dB at 60 cm distance |
| Operating temperature | −10…+40 °C |
| Operating voltage | AC 400 V–22 kV · 50/60 Hz |
|---|---|
| Theoretical alarm distances | 400 V → 0.25 m; 1 kV → 0.4 m; 6.6 kV → 1.0 m; 11 kV → 1.3 m; 22 kV → 1.9 m |
| Battery | 1 × CR1620 |
| Dimensions / weight | 77 × 40 × 14 mm · approx. 35 g |
| Sound level | At least 65 dB at 60 cm distance |
| Operating temperature | −10…+40 °C |
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
No. The sensitivity and operating range of the two models differ; the voltage–distance table of the relevant model must be referenced.
No. These are theoretical alarm references; they do not represent a fixed safe approach distance or a guarantee of protection.
Share the label of your legacy model and your application details with NOVEL. The designations HXW-6, HXW-6W, and HXW-6WL should not be automatically assumed to be the same product.
NOVEL technical support
Product name and order code are pre-populated in the email draft.