NOVEL · PRODUCT AND SYSTEM SOLUTIONS

PERGAM LMA Remote Laser Ammonia Leak Detector

LMA is a portable handheld TDLAS detector for remote ammonia leak investigation.

PERGAM LMA Remote Laser Ammonia Leak Detector

Plan the Right Configuration

LMA is a portable handheld TDLAS detector for remote ammonia leak investigation. It reports NH₃ integrated along the laser path in ppm·m. Its lightweight body, short response time and rechargeable battery support field inspections.

ppm·m expresses integrated gas concentration along the beam path and differs from a point ppm reading. The guide laser is specified as Class 3R and the measurement laser as Class 1; follow the manufacturer laser-safety instructions.

Request a Quote from NOVEL ↗

From need to solution

Survey hard-to-reach locations remotely

PERGAM LMA Remote Laser Ammonia Leak Detector: selection starts with the measurement or system output your team needs for its decision.

01

Customer need

Fences, height and access restrictions can prevent the operator from approaching every survey point.

02

Product output

The target-gas response along the laser path helps investigate suspect areas remotely; path-integrated and point concentrations are different quantities.

03

Decision supported

Prioritise locations for closer confirmation and plan the survey route while accounting for wind, target surfaces and line of sight.

← Laser Methane and Ammonia Gas Leak Detectors

Applications

Leak investigation around ammonia refrigeration systems, chemical processes and accessible pipe or equipment joints.

Technical Specifications

Model and Configuration
Model
LA1N03N-TGA
Target gas
Ammonia (NH₃)
Measurement range
1–50,000 ppm·m
Distance
0.5–30 m
Response
0.1 s
Battery
Built-in Li-ion, 5,750 mAh
Operating time
Approximately 8 hours; manufacturer reference at 25 °C
Weight
370 g

Accessories and Configuration Options

The manufacturer overview does not provide a separately coded accessory list for this model. Confirm the carrying, charging and installation scope with NOVEL for the exact configuration.

Options listed here are not a statement of standard delivery or current stock. Exact accessory codes and compatibility are confirmed against the model and ordered scope.

PRODUCT GUIDE

Frequently Asked Questions

Which gas is measured?

Model LA1N03N-TGA is designed for ammonia (NH₃).

What does ppm·m mean?

It is the integrated concentration along the laser beam path through the gas cloud.

Is 30 metres guaranteed at every site?

No. Evaluate the reflecting target, line of sight, environment and application conditions.

Original Manufacturer Resources

Visit the original manufacturer website ↗

NOVEL Technical Support

Share your application, target parameter and required output. We can help review the model and accessory selection.

Request a Quotation from NOVEL ↗