Customer need
Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.
NOVEL · Product and System Solutions
Gas Detectors and Industrial Measurement Instruments

From need to solution
Sensidyne SensAir: selection starts with the measurement or system output your team needs for its decision.
Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.
Readings, alarm states and supported outputs from the chosen sensor configuration provide information to the monitoring system.
Select sensors, locations and alarm response procedures according to the gas, potential release source and site conditions; one sensor does not cover every gas.

| Detected Gas | Combustible/Flammable Gases |
|---|---|
| Detection Principle | Sensitive Catalytic Sensor (Poison resistant catalytic bead) |
| Power Supply and Power Consumption | 24V DC, Nominal, up to 6 Watts, Voltage Range: 12-30V DC, Current Consumption (Max): 300mA (typically 125mA) Termination Resistance: less than 500Ω (250Ω recommended) |
| Construction | SensAir instruments are manufactured to be resistant to toxic poisons. Consequently, measurement results are unaffected by ambient chemicals and hydrocarbons. Furthermore, sensor lifespans are not degraded by ambient conditions. SensAir features a very rugged cast aluminium housing suitable for use in explosive atmospheres. This configuration features horizontal or vertical conduit orientation or a polycarbonate NEMA-rated enclosure. Display models feature a bright LED display, non-intrusive easy user interface, and maintenance screen. Both HD plastic and 316 stainless steel sensor housings provide excellent corrosion resistance. |
| Connection Outputs | 4-20mA via 3 wires (non-isolated) |
| Certifications and Safety Classification | FM US and Canadian | NEC/CEC Class I, Div 1, Groups A, B, C, D T4; Nonincendive for installation in Class 1 Division 2 Groups A, B, C, D (FM6320, C22.2 No. 152) ATEX CE 0518 II 2 G Ex d IIC T4 (FM13ATEX0066) II 3 G Ex nA d IIC T4 FM13ATEX0084). For detailed information, you can contact NOVEL. |
| Detected Gas | Toxic Gases |
|---|---|
| Detection Principle | Electrochemical Sensor |
| Power Supply and Power Consumption | 24V DC, Nominal, up to 6 Watts, Voltage Range: 12-30V DC, Current Consumption (Max): 300mA (typically 125mA) Termination Resistance: less than 500Ω (250Ω recommended) |
| Construction | SensAir instruments are manufactured to be resistant to toxic poisons. Consequently, measurement results are unaffected by ambient chemicals and hydrocarbons. Furthermore, sensor lifespans are not degraded by ambient conditions. SensAir features a very rugged cast aluminium housing suitable for use in explosive atmospheres. This configuration features horizontal or vertical conduit orientation or a polycarbonate NEMA-rated enclosure. Display models feature a bright LED display, non-intrusive easy user interface, and maintenance screen. Both HD plastic and 316 stainless steel sensor housings provide excellent corrosion resistance. |
| Connection Outputs | 4-20mA via 3 wires (non-isolated) |
| Certifications and Safety Classification | FM US and Canadian | NEC/CEC Class I, Div 1, Groups A, B, C, D T4; Nonincendive for installation in Class 1 Division 2 Groups A, B, C, D (FM6320, C22.2 No. 152) ATEX CE 0518 II 2 G Ex d IIC T4 (FM13ATEX0066) II 3 G Ex nA d IIC T4 FM13ATEX0084). For detailed information, you can contact NOVEL. |
| Detected Gas | Oxygen |
|---|---|
| Detection Principle | Electrochemical Sensor |
| Power Supply and Power Consumption | 24V DC, Nominal, up to 6 Watts, Voltage Range: 12-30V DC, Current Consumption (Max): 300mA (typically 125mA) Termination Resistance: less than 500Ω (250Ω recommended) |
| Construction | SensAir instruments are manufactured to be resistant to toxic poisons. Consequently, measurement results are unaffected by ambient chemicals and hydrocarbons. Furthermore, sensor lifespans are not degraded by ambient conditions. SensAir features a very rugged cast aluminium housing suitable for use in explosive atmospheres. This configuration features horizontal or vertical conduit orientation or a polycarbonate NEMA-rated enclosure. Display models feature a bright LED display, non-intrusive easy user interface, and maintenance screen. Both HD plastic and 316 stainless steel sensor housings provide excellent corrosion resistance. |
| Connection Outputs | 4-20mA via 3 wires (non-isolated) |
| Certifications and Safety Classification | FM US and Canadian | NEC/CEC Class I, Div 1, Groups A, B, C, D T4; Nonincendive for installation in Class 1 Division 2 Groups A, B, C, D (FM6320, C22.2 No. 152) ATEX CE 0518 II 2 G Ex d IIC T4 (FM13ATEX0066) II 3 G Ex nA d IIC T4 FM13ATEX0084). For detailed information, you can contact NOVEL. |
Fixed Sensidyne Gas Detector with Superior Sensor Technology
ATEX certified for Use in Explosion-Hazardous Areas (Zone 1 and Zone 2)
"316 Stainless Steel" Sensor Housing Suitable for Use in Explosive Atmospheres, Resistant to All Harsh Field Conditions
Speciality Sensors Resistant to Toxic Environments (sulphides and silicones), Capable of Rapid Target Gas Detection
Models with or without Backlit LED Display
Custom Design Providing Easy Installation and Low-Cost Post-Installation Maintenance (Sensor Replacement is Very Easy!)
Vertical or Horizontal Mounting Capability
4-20mA Analogue Output via 3-Wire Cable
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.