Customer need
Test rigs and technical applications need flow information to compare settings and produce repeatable records.
NOVEL · Products and system solutions

Thermal mass flow measurement with absolute pressure and temperature readings. Compare range, connection and gas options across the 4040/4043/4045 and 4140 families.
Request a Quote from NOVEL ↗From need to solution
TSI 4000 Series Analog and Digital Mass Flow Meters: selection starts with the measurement or system output your team needs for its decision.
Test rigs and technical applications need flow information to compare settings and produce repeatable records.
The gas, flow and additional channels supported by the selected model provide numerical data for the application.
Select range, gas compatibility, pressure drop, connections and outputs, distinguishing reference and actual volumetric conditions.
Platinum film sensing provides a 4 ms response with low pressure drop and no moving measuring elements.
Use analog flow output for control systems; transfer flow, absolute pressure and temperature via RS-232. Volume functions are accessed through serial commands.
Gas calibration, lower flow limit and connection dimensions vary by model. Evaluate both reading-percentage and minimum-error terms in the relevant specification.
Suitable for laboratory test benches, gas-flow verification and instrument development. Distinguish actual volumetric flow from mass/standard flow reported at reference conditions. For sampling pumps, verify the calibration method’s reference conditions and pressure drop of the complete sampling train.
| Model | Flow range | Connection | Gas calibration |
|---|---|---|---|
| 4040 | 0–300 L/min | 22 mm ISO | Air / O₂ / N₂ |
| 4045 | 0–300 L/min | ¾ in | Air / O₂ / N₂ |
| 40401 | 0–300 L/min | 22 mm ISO | Air |
| 4043 | 0–200 L/min | ½ in | Air / O₂ / N₂ |
| 41401 | 0.01–20 L/min | ¼ in | Air |
| 4140 | 0.01–20 L/min | ¼ in | Air / O₂ / N₂ |
| 4143 | 0.01–20 L/min | ⅜ in | Air / O₂ / N₂ |
| 41403 | 0.01–20 L/min | ¼ in | N₂O / Air / O₂ / N₂ |
| 41433 | 0.01–20 L/min | ⅜ in | N₂O / Air / O₂ / N₂ |
| Part number | Accessory |
|---|---|
| 8918-EC | Power adapter |
| 1303584 | 8-pin mini-DIN analog output cable |
| 1303583 | Computer interface cable |
| 1602317 / 1602300 / 1602345 | Inlet HEPA filter options selected for connection and pressure drop |
| 6017501 | 22 mm male/female HEPA filter |
| 4199 | Battery pack |
| 1319176 | Hard case for 4040/4043/4045 |
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL