Collect the Fraction Your Method Requires

A cyclone removes larger particles before the selected aerosol fraction reaches the filter. A personal pump draws a known air volume; the laboratory weighs or analyses the collected material. Choosing the wrong flow changes the size separation.

Request a Quote from NOVEL ↗

From need to solution

Sample the required aerosol fraction

Cyclone Heads for Respirable and Thoracic Dust Sampling: selection starts with the measurement or system output your team needs for its decision.

01

Customer need

Respirable or thoracic sampling needs an appropriate size-selective head and specified flow, in addition to a filter.

02

Product output

At the correct flow, the cyclone supports collection of the intended fraction on the filter.

03

Decision supported

Select the head, pump and filter together and check the assembled train; thoracic and respirable settings are not interchangeable.

Select a Cyclone

Sensidyne GK2.69

Sensidyne GK2.69

37 mm cassette · 1.6 L/min thoracic / 4.2 L/min respirable. Turkish and English manuals.

Technical details

Sensidyne GK2.69 — Thoracic and Respirable

Metal cyclone used with a 37 mm cassette. The manufacturer specifies 1.6 L/min for thoracic and 4.2 L/min for respirable sampling, corresponding to nominal D₅₀ values of 10 µm and 4 µm. These flows create different separation behaviour and are not interchangeable. Maintain inlet orientation and upright position.

Dorr–Oliver 10 mm Nylon

Dorr–Oliver 10 mm Nylon

Respirable sampling; NIOSH 0600 lists 1.7 L/min for the 10 mm nylon cyclone.

Technical details

Dorr–Oliver 10 mm Nylon Cyclone

Nylon cyclone used at 1.7 L/min in NIOSH 0600, which describes gravimetric respirable particulate sampling with a 37 mm PVC filter. Select compatible cassette adapter, holder and grit pot. Do not apply its flow to a cyclone of different geometry.

ZEFON Alüminyum / Aluminum

ZEFON Alüminyum / Aluminum

ZA0060 cyclone / ZA0062 starter kit. Confirm the manufacturer and method flow for the exact model.

Technical details

ZEFON ZA0060 Aluminium Cyclone

Aluminium respirable cyclone for compatible 37 mm filter cassettes, using the manufacturer’s 2.5 L/min configuration. Evaluate the lightweight body, holder and grit pot together; cleaning and leak checks help preserve separation performance.

ZA0060: 37 mm aluminium cyclone; a three-piece filter cassette is used with holder ZA0061. Nominal flow 2.5 L/min gives a 4 µm D50. Filter and complete sampling train must be selected for the analytical method.

Manufacturer technical description ↗

Higgins–Dewell

Higgins–Dewell

Generic respirable cyclone type described by HSE MDHS14/4; 2.2 L/min.

Technical details

Higgins–Dewell Cyclone

Cyclone arrangement described at 2.2 L/min for respirable sampling in HSE MDHS14/4. Select compatible filter holder and connections. Inhalable, thoracic and respirable fractions differ; report results against the actual fraction and method.

Part Numbers and Accessories After Technical Selection

Cyclones and sampler accessories — quotation list →

Flow and Fraction Comparison

Head / methodTarget fractionFlowSelection basis
GK2.69Thoracic1.6 L/minSensidyne Rev A · D50 10 µm
GK2.69Respirable4.2 L/minSensidyne Rev A · D50 4 µm
10 mm nylonRespirable1.7 L/minNIOSH 0600
Higgins–DewellRespirable2.2 L/minHSE MDHS14/4 · NIOSH 0600

D50 is an aerodynamic 50% cut point, not a filter pore size. These are source-specific operating values, not interchangeable settings for all cyclones.

Methods and Comparative Evidence

HSE MDHS14/4 describes gravimetric sampling of health-related aerosol fractions and lists GK2.69 for both thoracic and respirable use at different flows. NIOSH 0600 addresses respirable particulate mass; silica-specific analysis requires its own method. Published CDC-hosted research on aluminium cyclones found that flow choice affected bias relative to the ISO convention. Its findings must be applied to the tested design; they do not replace the GK2.69 manufacturer settings. Comparative Research ↗

Sampling Setup

Place the head in the breathing zone, retain the specified orientation, and calibrate the complete sampling train with the selected filter. Check flow before and after sampling, record duration and keep field blanks according to the method. Laboratory concentration depends on collected mass and sampled air volume.

Air sampling setup video
Sampling setup example. Follow the manual for the selected cyclone and cassette.

Frequently Asked Questions

What information is needed to select Cyclone Heads for Respirable and Thoracic Dust Sampling?

Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.

Where can I find accessories and technical documents?

Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.

Original Manufacturer Resources

Visit the original manufacturer website ↗

Let’s select the right solution for your application.

Share your application, target parameter and required output. We can help review the model and accessory selection.

Request a Quote from NOVEL ↗