Tedlar® PVF · ZP
EG-ZP-1 · 1 L · 10
NOVEL · Products and system solutions

Choose bag volume, film and valve for field gas collection and suitable laboratory analysis. Review coded options including EG-ZP-1 and assess sample compatibility.
Request a Quote from NOVEL ↗
Clear PVF film is used to collect compatible gas/VOC samples. Assess adsorption, permeation, moisture and blank effects of film and valve for the analysis.
The polypropylene ZP valve incorporates a PTFE septum and hanging hole. Other PP or stainless valves serve different connection and compatibility requirements.
Select volumes such as 0.5 L or 1 L to meet collection and analysis needs. An EA single bag and a box of 10 are different ordering units.
| Code | Volume | Film / Valve | Pack |
|---|---|---|---|
| EG-ZP-05EA | 0.5 L | Tedlar PVF / ZP | 1 |
| EG-ZP-05 | 0.5 L | Tedlar PVF / ZP | 10 |
| EG-ZP-1EA | 1 L | Tedlar PVF / ZP | 1 |
| EG-ZP-1 | 1 L | Tedlar PVF / ZP | 10 |
| EG-ZP-1-CSEA | 1 L | Tedlar PVF / ZP / Clip-Seal | 1 |
| EG-ZP-1-CS | 1 L | Tedlar PVF / ZP / Clip-Seal | 10 |
| EG-PP-05 | 0.5 L | Tedlar PVF / PP | — |
| EG-PP-1 | 1 L | Tedlar PVF / PP | — |
| EG-SS-05 | 0.5 L | Tedlar PVF / Stainless steel | — |
| EG-SS-1 | 1 L | Tedlar PVF / Stainless steel | — |
| FG-PP-05 | 0.5 L | FoilGrab / PP | — |
| NXT-90520 | 10 L | Veriair Flex / Foil | — |
EG-ZP-1: 2 mil PVF film, 1 L, ZP valve, 10 per box. Clip-Seal has a separate closure design for access and cleaning requirements. Reuse depends on blank checks and laboratory approval.
Use clean, leak-tight connections and stay within manufacturer filling limits. Do not pressurise a bag directly from a compressed-gas source. Protect it from sunlight, sharp surfaces, condensation and excessive heat.
Holding time depends on analyte stability, film and method; there is no universal period. Ask the laboratory about film/valve suitability for reactive gases, high humidity or trace levels. Bag sampling is not an automatic substitute for a canister method.
A bag provides a container for a whole-air grab sample or another method-approved gas sample. The laboratory determines whether bag material, valve, target compound and holding time are suitable. Choose a sampling pump, a lung sampler or another manufacturer-approved filling system so that the sample is not contaminated by unsuitable wetted parts. Bags do not provide an immediate concentration reading.
No. Reactivity, concentration, humidity, adsorption, permeation and analysis method determine suitability. Ask the laboratory to confirm film, valve and holding time.
EA codes shown here are single units; codes specified as 10 per box are different order units. Confirm the pack for unlisted codes.
NOVEL