Low-flow pump
A pump and, when required, low-flow adapter maintaining the method-specified flow.
NOVEL · Products and system solutions

Collect gases and vapours on a suitable sorbent for laboratory analysis. Select activated charcoal or other media, sorbent loading and sampling conditions by analyte and method.
Request a Quote from NOVEL ↗| ZEFON Code | Sorbent | OD × L (mm) | Sorbent (mg) |
|---|---|---|---|
| ZST-001 ↗ | Activated carbon | 6 × 70 | 100/50 |
| ZST-001B ↗ | Activated carbon | 6 × 70 | 100/50 |
| ZST-002 ↗ | Activated carbon | 8 × 110 | 400/200 |
| ZST-002B ↗ | Activated carbon | 8 × 110 | 400/200 |
| ZST-020 ↗ | Chromosorb-102 | 8 × 110 | 100/50 |
| ZST-021 ↗ | Chromosorb-102 | 8 × 110 | 200/100 |
| ZST-022 ↗ | Chromosorb-102 | 6 × 70 | 66/33 |
| ZST-040 ↗ | Microlite | 6 × 70 | 200 |
| ZST-041 ↗ | Microlite | 8 × 110 | 500 |
| ZST-050 ↗ | Silica Gel | 6 × 70 | 150/75 |
| ZST-051 ↗ | Silica Gel | 6 × 70 | 100/50 |
| ZST-052 ↗ | Silica Gel | 8 × 110 | 300/150 |
| ZST-053 ↗ | Silica Gel | 8 × 110 | 520/260 |
| ZST-054 ↗ | Silica Gel | 8 × 110 | Confirm with manufacturer |
| ZST-055 ↗ | Silica Gel (2,4-Dinitrophenyl hydrazine) | 6 × 110 | 300/150 |
| ZST-055A ↗ | Silica Gel (2,4-Dinitrophenyl hydrazine) | 6 × 110 | 300/150 |
| ZST-057 ↗ | Silica Gel (Sulfuric acid) | 6 × 70 | 200/100 |
| ZST-058 ↗ | Silica Gel | 10 × 110 | 1040/260 |
| ZST-060 ↗ | Silica Gel (Specially cleaned) | 7.2 × 110 | 400/200 |
| ZST-066 ↗ | Silica Gel (Sulfuric acid) | 6 × 70 | 150/75 |
| ZST-070 ↗ | Tenax | 6 × 70 | Confirm with manufacturer |
| ZST-071 ↗ | Tenax | 6 × 70 | Confirm with manufacturer |
| ZST-074 ↗ | Tenax | 8 × 110 | 100/50 |
| ZST-080 ↗ | XAD-2 | 8 × 110 | 100/50 |
| ZST-081 ↗ | XAD-2 | 7 × 70 | 80/40 |
| ZST-082 ↗ | XAD-2 | 8 × 110 | 100/30 |
| ZST-083 ↗ | XAD-2 | 8 × 110 | 150/75 |
| ZST-084 ↗ | XAD-2 | 8 × 110 | 400/200 |
| ZST-085 ↗ | XAD-2 (2- Hydroxymethyl) | 6 × 110 | 150/75 |
| ZST-086 ↗ | XAD-2 (2- Hydroxymethyl) | 6 × 110 | 120/60 |
| ZST-087 ↗ | XAD-2 (2- Hydroxymethyl piperidine) | 8 × 110 | 450/225 |
| ZST-088 ↗ | XAD-2 (2- Hydroxymethyl) | 6 × 70 | 45/23 |
| ZST-089 ↗ | XAD-2 (Octanoic acid) | 6 × 70 | 100/50 |
| ZST-090 ↗ | XAD-7 | 6 × 110 | 100/50 |
| ZST-091 ↗ | XAD-7 | 6 × 70 | 60/30 |
| ZST-100 ↗ | XAD-2 + (Naphtylisothiocyanate) | 6 × 70 | Confirm with manufacturer |
| ZST-120 ↗ | Porapak-N | 6 × 70 | 88/44 |
| ZST-125 ↗ | Porapak-P | 6 × 110 | 100/50 |
| ZST-130 ↗ | Porapak-Q | 6 × 110 | 150/75 |
| ZST-131 ↗ | Porapak-Q | Confirm with manufacturer | 78/39 |
| ZST-135 ↗ | Porapak-R | 6 × 70 | 70/35 |
| ZST-140 ↗ | Porapak-T (2 tubes) | 6 × 40 6 × 40 | 25 75 |
| ZST-150 ↗ | Molecular Sieve (Triethanolamine) | 7.2 × 110 | 400/200 |
| ZST-160 ↗ | Florisil | 6 × 70 | 100/50 |
| ZST-180 ↗ | Chromosorb-106 | 7.2 × 70 | 100/50 |
| ZST-181 ↗ | Chromosorb-106 | 10 × 150 | 600/300 |
| ZST-185 ↗ | Chromosorb-108 Anasorb 708 equivalent | 10 × 110 | 400/200 |
| ZST-200 ↗ | Anasorb 747 | 6 × 70 | 140/70 |
| ZST-220 ↗ | Soda Lime | 7 × 110 | 600/200 |
| ZST-300 ↗ | XAD-2/Glass Fiber Filter (OVS) | 13 to 8 × 75 | Confirm with manufacturer |
| ZST-300A ↗ | XAD-2/Glass Fiber (OVS) | 13 to 8 × 75 | 270/140 |
| ZST-301 ↗ | XAD-2/Quartz Filter (OVS) | 13 to 8 × 75 | 270/140 |
| ZST-302 ↗ | Tenax/Glass Fiber Filter (OVS) | 13 to 8 × 75 | 140/70 |
| ZST-303 ↗ | XAD-7/Glass Fiber Filter (OVS) | 13 to 8 × 75 | 200/100 |
| ZST-303A ↗ | XAD-7/Glass Fiber Filter (OVS) | 13 to 8 × 75 | 200/100 |
| ZST-304 ↗ | Silica Gel/Glass Fiber Filter (OVS) | 13 to 8 × 75 | 520/260 |
Activated charcoal is used for method-appropriate organic vapour sampling; silica gel may be specified for certain polar compounds. Different sorbents and loadings are not direct equivalents.
The manufacturer range includes activated carbon, silica gel, Tenax, Chromosorb, Porapak, XAD resins and OVS media. Blank confirmation fields reflect conflicting manufacturer entries; they are not inferred from another code. These are technical catalogue records, not a statement of current stock or delivery.
Start with compound, expected concentration, sampling duration and analytical method. Laboratory solvent extraction, desorption efficiency and interference controls must suit the sorbent.
The front bed collects the sample; the backup bed helps assess breakthrough. Do not combine beds. The laboratory evaluates the sections and acceptance criteria under the selected method.
Use a low-flow pump, tube holder and any required flow-control equipment. Keep flow and volume within method limits; humidity, temperature and high loading affect capacity. Record assembled-train pre/post flow.
Open ends with a suitable tube breaker and follow the flow arrow and manufacturer instructions. Use a holder to protect against broken glass. Cap, label and follow laboratory temperature/transport instructions afterwards.
A pump and, when required, low-flow adapter maintaining the method-specified flow.
A protective tube holder, connection tubing and suitable end-opening tool.
A calibrator covering the target flow for pre/post checks of the complete train.
The manufacturer’s reference table helps locate an existing code. A cross-reference is not unconditional equivalence: sorbent, bed mass, dimensions, treatment, analytical recovery and method must be checked before substitution. ZST-003 is present in this comparison but lacks a technical row in the current range above.
| ZEFON | SKC | Supelco / Sigma Aldrich |
|---|---|---|
| ZST-001 | 226-01 | ORBO™ 32 small |
| ZST-001B | 226-01B | ORBO™ 32 small |
| ZST-002 | 226-09 | ORBO™ 32 large |
| ZST-002B | 226-09B | ORBO™ 32 large |
| ZST-003 | 226-16 | — |
| ZST-020 | 226-107 | ORBO™ 706 |
| ZST-040 | 226-17-1A | ORBO™ 1002 |
| ZST-041 | 226-17-1A | ORBO™ 1008 |
| ZST-050 | 226-10 | ORBO™ 52 small |
| ZST-051 | 226-51 | ORBO™ 502 |
| ZST-052 | 226-10-04 | ORBO™ 506 |
| ZST-054 | 226-15 | ORBO™ 507 |
| ZST-055 | 226-119 | — |
| ZST-055A | 226-119A | — |
| ZST-058 | 226-22 | — |
| ZST-060 | 226-10-03 | ORBO™ 53 |
| ZST-066 | 226-53 | ORBO™ 554 |
| ZST-070 | 226-35 | — |
| ZST-074 | 226-35-03 | — |
| ZST-080 | 226-30-04 | ORBO™ 443/44 |
| ZST-083 | 226-30-05 | ORBO™ 608 |
| ZST-084 | 226-30-06 | ORBO™ 609 |
| ZST-085 | 226-117 | ORBO™ 24 |
| ZST-086 | 226-118 | ORBO™ 23 |
| ZST-087 | 226-27 | ORBO™ 25 |
| ZST-090 | 226-95 | ORBO™ 47 |
| ZST-091 | 226-94 | ORBO™ 615 |
| ZST-120 | 226-59-01 | — |
| ZST-125 | 226-114 | ORBO™ 1102 |
| ZST-130 | 226-115 | ORBO™ 1103 |
| ZST-135 | 226-59-04 | ORBO™ 1104 |
| ZST-160 | 226-39 | ORBO™ 60 |
| ZST-181 | 226-111A | ORBO™ 711 |
| ZST-200 | 226-81A | — |
No. The sorbent and any treatment are selected for the analytical method and target compound. A common glass tube shape does not make media interchangeable.
These are laboratory sampling tubes. Sampled mass, sampled air volume and method corrections are used to calculate concentration; they are not colourimetric detector tubes.
NOVEL