NOVEL · Products and system solutions

ZEFON Activated Charcoal and Silica Gel Sorbent Tubes

ZEFON Activated Charcoal and Silica Gel Sorbent Tubes

Product Overview

Collect gases and vapours on a suitable sorbent for laboratory analysis. Select activated charcoal or other media, sorbent loading and sampling conditions by analyte and method.

Request a Quote from NOVEL ↗

Media and Product Selection

ZEFON · 56 technical product records
ZEFON CodeSorbentOD × L (mm)Sorbent (mg)
ZST-001 ↗Activated carbon6 × 70100/50
ZST-001B ↗Activated carbon6 × 70100/50
ZST-002 ↗Activated carbon8 × 110400/200
ZST-002B ↗Activated carbon8 × 110400/200
ZST-020 ↗Chromosorb-1028 × 110100/50
ZST-021 ↗Chromosorb-1028 × 110200/100
ZST-022 ↗Chromosorb-1026 × 7066/33
ZST-040 ↗Microlite6 × 70200
ZST-041 ↗Microlite8 × 110500
ZST-050 ↗Silica Gel6 × 70150/75
ZST-051 ↗Silica Gel6 × 70100/50
ZST-052 ↗Silica Gel8 × 110300/150
ZST-053 ↗Silica Gel8 × 110520/260
ZST-054 ↗Silica Gel8 × 110Confirm with manufacturer
ZST-055 ↗Silica Gel (2,4-Dinitrophenyl hydrazine)6 × 110300/150
ZST-055A ↗Silica Gel (2,4-Dinitrophenyl hydrazine)6 × 110300/150
ZST-057 ↗Silica Gel (Sulfuric acid)6 × 70200/100
ZST-058 ↗Silica Gel10 × 1101040/260
ZST-060 ↗Silica Gel (Specially cleaned)7.2 × 110400/200
ZST-066 ↗Silica Gel (Sulfuric acid)6 × 70150/75
ZST-070 ↗Tenax6 × 70Confirm with manufacturer
ZST-071 ↗Tenax6 × 70Confirm with manufacturer
ZST-074 ↗Tenax8 × 110100/50
ZST-080 ↗XAD-28 × 110100/50
ZST-081 ↗XAD-27 × 7080/40
ZST-082 ↗XAD-28 × 110100/30
ZST-083 ↗XAD-28 × 110150/75
ZST-084 ↗XAD-28 × 110400/200
ZST-085 ↗XAD-2 (2- Hydroxymethyl)6 × 110150/75
ZST-086 ↗XAD-2 (2- Hydroxymethyl)6 × 110120/60
ZST-087 ↗XAD-2 (2- Hydroxymethyl piperidine)8 × 110450/225
ZST-088 ↗XAD-2 (2- Hydroxymethyl)6 × 7045/23
ZST-089 ↗XAD-2 (Octanoic acid)6 × 70100/50
ZST-090 ↗XAD-76 × 110100/50
ZST-091 ↗XAD-76 × 7060/30
ZST-100 ↗XAD-2 + (Naphtylisothiocyanate)6 × 70Confirm with manufacturer
ZST-120 ↗Porapak-N6 × 7088/44
ZST-125 ↗Porapak-P6 × 110100/50
ZST-130 ↗Porapak-Q6 × 110150/75
ZST-131 ↗Porapak-QConfirm with manufacturer78/39
ZST-135 ↗Porapak-R6 × 7070/35
ZST-140 ↗Porapak-T (2 tubes)6 × 40 6 × 4025 75
ZST-150 ↗Molecular Sieve (Triethanolamine)7.2 × 110400/200
ZST-160 ↗Florisil6 × 70100/50
ZST-180 ↗Chromosorb-1067.2 × 70100/50
ZST-181 ↗Chromosorb-10610 × 150600/300
ZST-185 ↗Chromosorb-108 Anasorb 708 equivalent10 × 110400/200
ZST-200 ↗Anasorb 7476 × 70140/70
ZST-220 ↗Soda Lime7 × 110600/200
ZST-300 ↗XAD-2/Glass Fiber Filter (OVS)13 to 8 × 75Confirm with manufacturer
ZST-300A ↗XAD-2/Glass Fiber (OVS)13 to 8 × 75270/140
ZST-301 ↗XAD-2/Quartz Filter (OVS)13 to 8 × 75270/140
ZST-302 ↗Tenax/Glass Fiber Filter (OVS)13 to 8 × 75140/70
ZST-303 ↗XAD-7/Glass Fiber Filter (OVS)13 to 8 × 75200/100
ZST-303A ↗XAD-7/Glass Fiber Filter (OVS)13 to 8 × 75200/100
ZST-304 ↗Silica Gel/Glass Fiber Filter (OVS)13 to 8 × 75520/260

Activated charcoal is used for method-appropriate organic vapour sampling; silica gel may be specified for certain polar compounds. Different sorbents and loadings are not direct equivalents.

The manufacturer range includes activated carbon, silica gel, Tenax, Chromosorb, Porapak, XAD resins and OVS media. Blank confirmation fields reflect conflicting manufacturer entries; they are not inferred from another code. These are technical catalogue records, not a statement of current stock or delivery.

Selecting an Activated Charcoal Tube

Target chemical and analysis

Start with compound, expected concentration, sampling duration and analytical method. Laboratory solvent extraction, desorption efficiency and interference controls must suit the sorbent.

Why front and backup sections?

The front bed collects the sample; the backup bed helps assess breakthrough. Do not combine beds. The laboratory evaluates the sections and acceptance criteria under the selected method.

Flow, volume and conditions

Use a low-flow pump, tube holder and any required flow-control equipment. Keep flow and volume within method limits; humidity, temperature and high loading affect capacity. Record assembled-train pre/post flow.

Opening, direction and storage

Open ends with a suitable tube breaker and follow the flow arrow and manufacturer instructions. Use a holder to protect against broken glass. Cap, label and follow laboratory temperature/transport instructions afterwards.

A Complete Sampling Setup

Low-flow pump

A pump and, when required, low-flow adapter maintaining the method-specified flow.

Holder and breaker

A protective tube holder, connection tubing and suitable end-opening tool.

Flow calibrator

A calibrator covering the target flow for pre/post checks of the complete train.

Part Numbers and Quantities

Browse activated charcoal and sorbent tubes →

Manufacturer and Technical Sources

ZEFON / SKC / Supelco Cross-reference

The manufacturer’s reference table helps locate an existing code. A cross-reference is not unconditional equivalence: sorbent, bed mass, dimensions, treatment, analytical recovery and method must be checked before substitution. ZST-003 is present in this comparison but lacks a technical row in the current range above.

Show 34 cross-references
ZEFONSKCSupelco / Sigma Aldrich
ZST-001226-01ORBO™ 32 small
ZST-001B226-01BORBO™ 32 small
ZST-002226-09ORBO™ 32 large
ZST-002B226-09BORBO™ 32 large
ZST-003226-16—
ZST-020226-107ORBO™ 706
ZST-040226-17-1AORBO™ 1002
ZST-041226-17-1AORBO™ 1008
ZST-050226-10ORBO™ 52 small
ZST-051226-51ORBO™ 502
ZST-052226-10-04ORBO™ 506
ZST-054226-15ORBO™ 507
ZST-055226-119—
ZST-055A226-119A—
ZST-058226-22—
ZST-060226-10-03ORBO™ 53
ZST-066226-53ORBO™ 554
ZST-070226-35—
ZST-074226-35-03—
ZST-080226-30-04ORBO™ 443/44
ZST-083226-30-05ORBO™ 608
ZST-084226-30-06ORBO™ 609
ZST-085226-117ORBO™ 24
ZST-086226-118ORBO™ 23
ZST-087226-27ORBO™ 25
ZST-090226-95ORBO™ 47
ZST-091226-94ORBO™ 615
ZST-120226-59-01—
ZST-125226-114ORBO™ 1102
ZST-130226-115ORBO™ 1103
ZST-135226-59-04ORBO™ 1104
ZST-160226-39ORBO™ 60
ZST-181226-111AORBO™ 711
ZST-200226-81A—

Manufacturer Instructions

Frequently Asked Questions

Do all ZST tubes measure the same VOCs?

No. The sorbent and any treatment are selected for the analytical method and target compound. A common glass tube shape does not make media interchangeable.

Can I read concentration directly from the tube?

These are laboratory sampling tubes. Sampled mass, sampled air volume and method corrections are used to calculate concentration; they are not colourimetric detector tubes.

NOVEL