Customer need
Converting collected mass to airborne concentration requires the sampling flow to be known.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

From need to solution
Gilian Gilibrator-3: selection starts with the measurement or system output your team needs for its decision.
Converting collected mass to airborne concentration requires the sampling flow to be known.
A flow calibrator provides a measurement for checking the assembled sampling train and comparing pump settings.
Record pre- and post-sampling checks and select a calibrator for the required flow range, connections and uncertainty.





| Flow Range | Low Flow Module: 5-450 cc/min (0.005-0.45 Litres/minute) Standard Flow Module: 50-5000 cc/min (0.05-5 Litres/minute) High Flow Module: 1000-30000 cc/min (1-30 Litres/minute) |
|---|---|
| Sensitivity | Volumetric accuracy: 1% of the reading or 0.003 L/min, whichever is greater. |
| Sampling Mode | Instantaneous measurement or averaging; 3–20 measurements can be selected for averaging. |
| Power Status | 8 hours of continuous use at minimum screen brightness; 3 hours at maximum flow. Charging via a 12 VDC adapter or USB. |
| Connectivity Features | Data transfer via SD memory card; RS-232 option for pump connections, USB option for data transfer |
| Dimensions and Weight | 168 × 234 × 81 mm; base unit: 1,270 g; low-flow cell: 363 g; standard-flow cell: 385 g; high-flow cell: 454 g. |
| Certifications | EN 61010-1, CE, RoHS and EMC compliance; internal battery transport approval to UN/DOT 38.3 and IEC 62133-2 (2nd edition). |
The New Standard in Calibration Instruments The Gilibrator-3 is the most advanced air flow calibrator on the market, designed to provide performance, reliability, and ease of use. Gilibrator 3 is an ideal instrument for calibration integrity and data reporting. Gilibrator 3 is a primary air flow calibrator under the NIOSH definition and provides NIST traceability through Sensidyne’s ISO 17025 accredited laboratory.
Full Functionality with a Superb Touchscreen LCD Gilibrator-3 features a colour touchscreen LCD that offers comfortable operation even in direct sunlight. Through this display, you can monitor and fully manage the calibration being performed. Viewing history, managing settings, or adding a reminder for the next calibration is straightforward thanks to its user-friendly interface.
Calibration Whenever and Wherever You Require Thanks to its dry-cell compact design, unlike other primary calibrators, Gilibrator-3 can be deployed comfortably in the field as well as in laboratory settings. Pre- and post-sampling calibration of pumps can be performed across a flow range of 5cc/min to 30,000cc/min.
High-Accuracy Calibration At the core of Gilibrator-3 is patented StablFlow technology, which maintains low backpressure on calibrated devices. Unlike other calibrators on the market, this patented design provides live, continuous air flow readings with 1% reading accuracy. Because it provides stable results throughout calibration, you can perform your pump calibration accurately and reliably with ease.
Extensive Connectivity Options and Fast Calibration Reporting Gilibrator-3 can generate printable calibration reports. The instrument can store 100 time-stamped calibration reports in its internal memory. Historical records can be reviewed for statistical analysis via these calibration data. In addition, its memory can be expanded via the onboard SD memory card slot, allowing easy export of data to a memory card. It connects directly to a PC via the Gilian CONNECT software and directly to GilAir Plus® pumps equipped with the SmartCal™ feature.
Overview of the Gilibrator-3 Primary Air Flow Calibrator
Operation of the Gilibrator-3 Primary Air Flow Calibrator Instrument
Setting Up the Gilibrator-3 Primary Air Flow Calibrator
Establishing an Air Calibration Connection Bridge with the Gilibrator-3 Primary Air Flow Calibrator
Gilibrator-3 Primary Air Flow Calibrator Device and Display Settings
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.