Customer need
Sampling requires air to be drawn from the breathing zone or a selected location at the flow and duration specified by the method.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

Extremely broad application range in dust, aerosol, fibre, gas, VOC, and vapour samplings. GilAir Plus is designed to enable occupational hygiene professionals to use a single pump platform across diverse sampling methods.
From need to solution
Gilian GilAir Plus Personal Air Sampling Pump: selection starts with the measurement or system output your team needs for its decision.
Sampling requires air to be drawn from the breathing zone or a selected location at the flow and duration specified by the method.
Air passed through the appropriate filter, cassette, cyclone or sorbent tube creates a sample for analysis; the pump alone does not measure contaminant concentration.
Relate the laboratory result to sampled air volume, selecting media and flow together and calibrating the assembled sampling train.
With personal air sampling pumps such as the GilAir Plus, the pump alone does not determine the analytical result. Flow rate, sampling head, filter or sorbent tube, sampling duration, and analytical method must be selected together in accordance with the applicable national or international standard. ISO 13137:2013 is one of the principal references for the performance requirements of personal air sampling pumps. Verifying the flow rate with an appropriate flow calibrator before and after sampling is recommended.
| Flow Range | Constant-flow operation at 20–5,100 cc/min; constant-pressure operation at 1–5,100 cc/min. |
|---|---|
| Constant Flow Control | ± 5% or ± 3 cc/min (whichever is greater) |
| Display Indications | Flow rate, total sampling time and volume, flow fault, battery power indicator, programming mode |
| Runtime | At least 8 hours at the flow/backpressure combinations specified in the manufacturer manual; actual runtime depends on battery condition and operating conditions. |
| Weight | 580 g |
| Compliance / Approvals | For use in a hazardous area, refer to the current manufacturer certificate and its scope for the selected model. Contact NOVEL before purchase to confirm the model, flow range and options for your application. |
| QuadMode™ | Constant flow or constant pressure control at low and high flows; pump architecture requiring no external low-flow adapter. |
| Backpressure | Backpressure capability up to 40 inH₂O in low and high flow modes is specified in current manufacturer product details; flow-dependent runtimes and specifications should be checked separately. |
The Only Air Sampling Pump Incorporating All Desired Features
Gilian GilAir Plus is a new-generation sampling pump developed taking into account user demands and field research. It can be used with suitable media and accessories in dust, aerosol, gas, and VOC/vapour sampling; it also supports gas bag sampling applications.
Low and High Flow Applications in a Single Instrument
Thanks to QuadMode™ technology, it covers an operating range of 20–5,100 cc/min in constant flow and 1–5,100 cc/min in constant pressure without an external low-flow adapter. It reduces the requirement for separate pumps for low and medium/high flow samplings.
Superior Features, Compact Design
Despite its wide operating range, its portable form factor is well suited to personal occupational hygiene sampling. Flow rate, sampling runtime, volume, battery status, and operating parameters can be viewed on the large LCD screen.
Motion Detection, Bluetooth, and Data Management
Motion detection and Bluetooth connectivity on compatible configurations help inspect the pump without disturbing the worker. Datalog/STP models and the Gilian Connect infrastructure support the management of sampling records.
Temperature and Pressure Correction
The STP model measures ambient temperature and barometric pressure, allowing it to correct sampling volume and flow to selected standard conditions; it supports flow accuracy against variations arising from altitude.
Charging, Programming, and SmartCal™
Optional docking stations facilitate charging, data transfer, reporting, and automated calibration routines on compatible models. Advanced functions such as programmed start/stop, constant flow or constant pressure modes, and fault management are provided.
The SmartCal automated calibration routine requires a communication dock alongside the specific SmartCal interface cable designated for the target calibrator.
These are manufacturer order codes. Included items depend on the selected kit; battery, dock, cable and area-use compatibility are checked at quotation.
| Manufacturer Code | Description / compatibility |
|---|---|
| 783-0012-01-R | Rechargeable NiMH battery pack |
| 783-0013-01-R | AA alkaline battery pack |
| 783-0014-01-R | Desktop DC power supply pack (for area sampling only) |
| 811-0905-01-R | Inlet filter (pack of 10) |
| 811-0934-01-R | Screw-on belt clip |
| 811-0907-01-R | Dock-to-PC USB cable (for communication dock only) |
| 811-0913-01-R | Bag-fill outlet adapter |
| 811-0914-01-R | Tripod mount adapter |
| 811-0916-01-R | Manifold filter and gasket kit |
| 800143 | Filter cassette holder |
| 800149 | Single tube holder (for 6x70 mm, 150 mg charcoal tube) |
| Manufacturer Code | Description / compatibility |
|---|---|
| 780-0015-01-R | SmartCal cable (for 25-pin Gilibrator 2) |
| 780-0015-02-R | SmartCal cable (for Go-Cal Pro and Challenger calibrators) |
| 780-0015-03-R | SmartCal cable (for TSI 4146 calibrator) |
| 780-0015-04-R | SmartCal cable (for BIOS Defender calibrator) |
| 780-0015-05-R | SmartCal cable (for 9-pin Gilibrator 3 and Gilibrator 2 USB) |
GilAir Plus covers 20–5100 mL/min constant flow without an external low-flow adapter. Constant-pressure and multiple-tube setups require the specified holder/connections. Set up the complete sampling train, verify flow at the sampling-head inlet before and after use, and record the result. A field flow check does not replace periodic laboratory calibration.

GK2.69
Thoracic fraction at 1.6 L/min; respirable fraction at 4.2 L/min. Select the fraction by flow and confirm that the pump maintains it under filter load.

IOM · 2 L/dk
Samples the inhalable dust fraction at 2 L/min. Select the filter and internal cassette for the weighing/analytical method.

25 / 37 mm · metot seçimi
Choose MCE, PVC, PTFE or another filter for the analyte and laboratory method. Match cassette diameter, sections, pore size and flow in the sampling plan.

Sorbent · metot seçimi
For gas/vapour sampling select sorbent, tube dimensions, duration and low flow by method. Tube holder, breaker and connection tubing complete the train.
Impinger · sıvı tutucu
Liquid collection methods require an upright bottle holder and a trap protecting the pump. The analytical method determines flow, absorbing liquid and sample volume.

Gilibrator 3 · hücre seçimi
Dry cells: low 5–450 mL/min, standard 50–5000 mL/min, high 1–30 L/min. Select the cell covering the sampling flow; check before/after sampling with head, filter and tubing assembled.
A correct sampling system is established by selecting the pump, method-compliant sampling media/head, and flow calibrator in conjunction.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.