Customer need
Operators need a clear view of alarms, faults and the relationship between detection points and connected equipment.
NOVEL · Product and System Solutions
New Cosmos V3 / V3-M Gas Alarm Indicator and Control Unit
Gas Detectors and Industrial Measurement Instruments

The New Cosmos V3 series is a compact indicator family that makes measurement data from flammable gas, toxic gas and oxygen detectors visible to operators, helping establish a centralised gas safety infrastructure alongside the VAS alarm unit. V3-M provides an integration option with suitable 4–20 mA output detectors.
From need to solution
New Cosmos V3 / V3-M: selection starts with the measurement or system output your team needs for its decision.
Operators need a clear view of alarms, faults and the relationship between detection points and connected equipment.
Signals from compatible detectors and the panel’s supported relay or communication outputs provide central status information.
Design monitoring, ventilation and alarm sequences together, checking detector, power and output compatibility; the panel itself is not the gas sensor.
1. Field detector: The New Cosmos gas detector measures the target gas with a suitable sensor and transmits its model-specific electrical signal. 2. V3 indicator: displays the gas concentration on a 50-segment LED bargraph; signals alarm and fault conditions. 3. VAS alarm unit: connects to facility safety functions via audible alert and two-stage alarm contacts in a suitable installation.
From an operational perspective, its advantage is that it provides point-based gas monitoring, maintenance mode and centralized alarm organisation in existing industrial panel infrastructures. In installations across OIZ facilities, natural gas lines, chemical, metal, energy and process industries, it is addressed alongside project requirements.
Maintenance modeallows external alarm outputs to be managed during servicing and calibration in a suitable system configuration; it does not substitute for periodic functional testing and calibration of the detector. Alarm levels and ventilation/plant shutdown scenarios must be designed in accordance with the installation risk analysis.
| Type | Hv, Hi, Cv, Ci, Tv, Ti, D, O, and M |
|---|---|
| Gas Concentration Display | 50-segment, 3-colour LED bargraph display |
| Alarm Indication | Power Lamp: Green light flashes for 30 seconds at power-on, illuminates continuously while instrument is powered Alarm Lamp: Red light flashes Fault Lamp: Yellow light flashes |
| Alarm Values | Measurement ranges defined separately for 1st and 2nd stages |
| Alarm Accuracy | Flammable gas: ±25% of alarm setting; toxic gas: ±30%; oxygen: ±1.0 %vol. V3-M: according to connected detector specifications. |
| Response Time | Flammable Gas: Within 30 seconds, at 160% concentration of set value Toxic Gas: Within 60 seconds, at 160% concentration of set value Oxygen: Within 5 seconds at 10.0 vol% (oxygen deficiency) Type M: Varies according to detector head specifications. |
| Connection Outputs | 4–20 mA DC analogue output (depending on model/delivery configuration); alarm and fault contacts |
| Power Supply | 24 V DC ±10% (manufacturer exceptions may apply depending on connected detector) |
| Other Features | Verification, Maintenance mode, Reset Optional; Peak Hold Function, Alarm delay, Low flow rate alarm function (Set by connecting detector) |
| Operating Temperature/Humidity | −10 … +40 °C; 10–90% relative humidity (non-condensing) |
| Dimensions | 36 x 144 x 70 mm |
| Weight | Approximately 600 g with single housing (standard) or approximately 540 g (short housing) |
New Cosmos V3 is not an indicator with a single universal input. Hv/Hi, Cv/Ci, Tv/Ti, D, O and M types are selected according to the sensor or signal principle of the matching gas detector.
| V3 Type | Sensor / signal principle | Typical application |
|---|---|---|
| Hv / Hi | Hot-wire semiconductor | Monitoring of flammable gases such as methane, LPG etc.; selection according to detector type to be matched. |
| Cv / Ci | Catalytic combustion | Flammable gases and %LEL-based applications. |
| Tv / Ti | Thermal conductivity | H₂, He, Ar, CO₂ or suitable process gas analyses. |
| D | Electrochemical sensor | CO, H₂S and selected other toxic / speciality gases. |
| O | Galvanic oxygen sensor | Oxygen deficiency or enrichment monitoring. |
| M | Analogue signal input (suitable 4–20 mA transmitters) | Project-based configuration for detectors with suitable analogue outputs such as KD-12, PD-12. |
Alarm Status is easily recognised with 3-Colour LED Display.
Compatible with Various Gas Detectors, 4-20mA Analogue output is available.
Maintenance mode allows interruption of signals sent to alarm units. In this way, maintenance of units can be carried out individually with ease.
Easy to maintain; units can be easily replaced with new ones in the event of any malfunction.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
V3 is not a gas sensor on its own. It is an indicator unit that displays the measurement signal from the compatible detector in the field. It operates as part of a fixed gas detection system alongside the VAS alarm unit and suitable control outputs.
V3-M can be evaluated for suitable 4–20 mA output KD-12 and PD-12 configurations. The detector's exact model code, signal type, power supply, cabling and required CE combination must be verified prior to ordering.
Hv/Hi is for hot-wire semiconductor, Cv/Ci for catalytic combustion, Tv/Ti for thermal conductivity, D for electrochemical, O for galvanic oxygen, and M for suitable analogue signal inputs. Input connections of the models are not identical.
No. CE conformity depends on the specific indicator, metal housing and version combination. Order-specific verification must be conducted based on the V3-M CE document on the NOVEL page and current manufacturer documentation.
No. V3 is an indicator that displays gas concentration and alarm status. VAS is an alarm unit that provides audible warning, two-stage alarm and fault contacts in a suitable configuration.
The manufacturer's V3 technical table includes a 4–20 mA analogue output in suitable configurations and dry contacts for alarm/fault. Output and wiring details must be verified according to the selected indicator, detector and system schematic.
It can be used to monitor signals from fixed gas detectors on panels in industrial facilities; within gas alarm systems in OIZ, energy, gas infrastructure, petrochemical, automotive and metallurgical plants.
No. Maintenance mode helps manage alarm outputs following the appropriate procedure during servicing. Functional bump testing with gas and calibration of the detector must be performed separately in accordance with manufacturer instructions and facility maintenance schedules.
Links to the NOVEL brochure, Turkish catalogue, English instruction manual and V3-M CE document at the top of the page have also been retained.