New Cosmos V3 / V3-M Gas Alarm Indicator and Control Unit

Gas Detectors and Industrial Measurement Instruments

New Cosmos V3-M gas alarm indicator, panel control unit with tri-colour LED bar graph

New Cosmos V3 / V3-M Gas Alarm Indicator and Control Unit

The New Cosmos V3 series is a compact indicator family that makes measurement data from flammable gas, toxic gas and oxygen detectors visible to operators, helping establish a centralised gas safety infrastructure alongside the VAS alarm unit. V3-M provides an integration option with suitable 4–20 mA output detectors.

Request a Quote from NOVEL ↗



Modular indicator, two-stage alarm and 4–20 mA control solutions for fixed gas detectors

3-colour LED bargraph50-segment concentration and alarm status display.
2-stage gas alarmAudible/visual notification and contacts via VAS alarm unit.
4–20 mA ecosystemSuitable analogue detector and control integration with V3-M type.

Product Specifications

  • Alarm Status is easily recognised with 3-Colour LED Display.

  • Compatible with Various Gas Detectors, 4-20mA Analogue output is available.

  • Maintenance mode allows interruption of signals sent to alarm units. In this way, maintenance of units can be carried out individually with ease.

  • Easy to maintain; units can be easily replaced with new ones in the event of any malfunction.

  • Product Documents

    Technical Specifications

    Show Technical Details
    Type Hv, Hi, Cv, Ci, Tv, Ti, D, O, and M
    Gas Concentration Display 50-segment, 3-colour LED bargraph display
    Alarm Indication Power Lamp: Green light flashes for 30 seconds at power-on, illuminates continuously while instrument is powered
    Alarm Lamp: Red light flashes
    Fault Lamp: Yellow light flashes
    Alarm Values Measurement ranges defined separately for 1st and 2nd stages
    Alarm Accuracy Flammable gas: ±25% of alarm setting; toxic gas: ±30%; oxygen: ±1.0 %vol. V3-M: according to connected detector specifications.
    Response Time Flammable Gas: Within 30 seconds, at 160% concentration of set value
    Toxic Gas: Within 60 seconds, at 160% concentration of set value
    Oxygen: Within 5 seconds at 10.0 vol% (oxygen deficiency)

    Type M: Varies according to detector head specifications.
    Connection Outputs 4–20 mA DC analogue output (depending on model/delivery configuration); alarm and fault contacts
    Power Supply 24 V DC ±10% (manufacturer exceptions may apply depending on connected detector)
    Other Features Verification, Maintenance mode, Reset
    Optional; Peak Hold Function, Alarm delay,
    Low flow rate alarm function (Set by connecting detector)
    Operating Temperature/Humidity −10 … +40 °C; 10–90% relative humidity (non-condensing)
    Dimensions 36 x 144 x 70 mm
    Weight Approximately 600 g with single housing (standard) or approximately 540 g (short housing)

    V3 Models – Sensor Principle and Detector Compatibility Table

    New Cosmos V3 is not an indicator with a single universal input. Hv/Hi, Cv/Ci, Tv/Ti, D, O and M types are selected according to the sensor or signal principle of the matching gas detector.

    V3 TypeSensor / signal principleTypical application
    Hv / HiHot-wire semiconductorMonitoring of flammable gases such as methane, LPG etc.; selection according to detector type to be matched.
    Cv / CiCatalytic combustionFlammable gases and %LEL-based applications.
    Tv / TiThermal conductivityH₂, He, Ar, CO₂ or suitable process gas analyses.
    DElectrochemical sensorCO, H₂S and selected other toxic / speciality gases.
    OGalvanic oxygen sensorOxygen deficiency or enrichment monitoring.
    MAnalogue signal input (suitable 4–20 mA transmitters)Project-based configuration for detectors with suitable analogue outputs such as KD-12, PD-12.
    Selection notice: Electrical connections of two detectors measuring the same gas may not be identical. V3 model type, detector output, power supply, alarm contacts, cabling and CE-certified combination must be verified with NOVEL prior to purchase.

    How Does the V3 / VAS Gas Detection System Work?

    1. Field detector: The New Cosmos gas detector measures the target gas with a suitable sensor and transmits its model-specific electrical signal. 2. V3 indicator: displays the gas concentration on a 50-segment LED bargraph; signals alarm and fault conditions. 3. VAS alarm unit: connects to facility safety functions via audible alert and two-stage alarm contacts in a suitable installation.

    V3-M, KD-12 and PD-12: For suitable 4–20 mA output versions of KD-12 / PD-12, the V3-M option is evaluated. Types V3-H, V3-C or V3-T are not considered direct equivalents. Suitability must be confirmed via detector model code, cabling and delivery specifications.

    From an operational perspective, its advantage is that it provides point-based gas monitoring, maintenance mode and centralized alarm organisation in existing industrial panel infrastructures. In installations across OIZ facilities, natural gas lines, chemical, metal, energy and process industries, it is addressed alongside project requirements.

    V3-M CE, Alarm Safety and Maintenance Notes

    CE scope: The V3-M CE document on this page does not imply automatic conformity for every V3 variant and every metal housing combination. The manufacturer instruction manual specifies that the housing configuration designated with V3-M is CE-certified. Prior to ordering, the current document, product code and housing combination must be verified together.

    Maintenance modeallows external alarm outputs to be managed during servicing and calibration in a suitable system configuration; it does not substitute for periodic functional testing and calibration of the detector. Alarm levels and ventilation/plant shutdown scenarios must be designed in accordance with the installation risk analysis.

    Manufacturer Resources and Technical Documents

    Links to the NOVEL brochure, Turkish catalogue, English instruction manual and V3-M CE document at the top of the page have also been retained.

    Gas Detection and Standards Approach

    Control and alarm system approach: In fixed gas detection systems, the detector, control/indicator unit, alarm outputs and field automation must be evaluated as an integrated whole. EN 50271 and relevant EN/IEC 60079-29 series standards may serve as references in application and system design; model-based conformity must be verified with the manufacturer's current certificates. The V3-M document should not be interpreted as ATEX certification or certification belonging to the entire V3 series without verifying the model/metal housing combination.

    Sectors

    Alternative Products

    You can examine product details and technical specifications by selecting an alternative suited to your requirements.

    Frequently Asked Questions About New Cosmos V3

    Is the New Cosmos V3 a gas detector or a gas alarm indicator?

    V3 is not a gas sensor on its own. It is an indicator unit that displays the measurement signal from the compatible detector in the field. It operates as part of a fixed gas detection system alongside the VAS alarm unit and suitable control outputs.

    Can the V3-M indicator operate with KD-12 and PD-12 detectors?

    V3-M can be evaluated for suitable 4–20 mA output KD-12 and PD-12 configurations. The detector's exact model code, signal type, power supply, cabling and required CE combination must be verified prior to ordering.

    What is the difference between V3-H, V3-C, V3-T, V3-D, V3-O and V3-M?

    Hv/Hi is for hot-wire semiconductor, Cv/Ci for catalytic combustion, Tv/Ti for thermal conductivity, D for electrochemical, O for galvanic oxygen, and M for suitable analogue signal inputs. Input connections of the models are not identical.

    Is the V3-M CE certificate valid for all V3 models?

    No. CE conformity depends on the specific indicator, metal housing and version combination. Order-specific verification must be conducted based on the V3-M CE document on the NOVEL page and current manufacturer documentation.

    Are V3 and VAS the same device?

    No. V3 is an indicator that displays gas concentration and alarm status. VAS is an alarm unit that provides audible warning, two-stage alarm and fault contacts in a suitable configuration.

    What are the outputs of the V3 alarm panel?

    The manufacturer's V3 technical table includes a 4–20 mA analogue output in suitable configurations and dry contacts for alarm/fault. Output and wiring details must be verified according to the selected indicator, detector and system schematic.

    Where is the V3 gas indicator used?

    It can be used to monitor signals from fixed gas detectors on panels in industrial facilities; within gas alarm systems in OIZ, energy, gas infrastructure, petrochemical, automotive and metallurgical plants.

    Does V3 maintenance mode substitute for gas detector calibration?

    No. Maintenance mode helps manage alarm outputs following the appropriate procedure during servicing. Functional bump testing with gas and calibration of the detector must be performed separately in accordance with manufacturer instructions and facility maintenance schedules.

    Notice: The technical information, product specifications and images on this page are based on manufacturer publications. The manufacturer may change specifications without notice. For current specifications or assistance in selecting a suitable product for your application, please contact NOVEL at info@novel.com.tr .

    NOVEL technical support