Customer need
Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.
NOVEL · Product and System Solutions
Gas Detectors - Fixed Gas Detectors

The New Cosmos KD12 is used to detect leaks or deficiencies of oxygen, methane and carbon dioxide, as well as many explosive gases. The New Cosmos KD12 displays the concentration of the target gas and outputs an analogue signal between 4-20 mA DC representing this concentration to an external device. When a set concentration is reached, the red lamp and alarm relays activate, making the New Cosmos KD12 an ideal device for monitoring gas concentrations.
Maintenance is vital for the trouble-free operation of Gas Detection and Alarm systems. Always take care to ensure the maintenance and calibration of your instrument.
From need to solution
New Cosmos KD-12 Series: selection starts with the measurement or system output your team needs for its decision.
Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.
Readings, alarm states and supported outputs from the chosen sensor configuration provide information to the monitoring system.
Select sensors, locations and alarm response procedures according to the gas, potential release source and site conditions; one sensor does not cover every gas.
| Sensor Type | Hot-Wire Semiconductor Sensor |
|---|---|
| Detected Gas | Combustible/flammable gases, toxic gases |
| Detected Gas Range | According to Specifications |
| Alarm Accuracy | For Flammable Gases: ±25% of set alarm value For Toxic Gases: ±30% of set alarm value |
| Operating Temperature/Humidity | -100°C to +500°C, 10% - 90% Relative Humidity |
| Dimensions | 158 x 116 x 68 mm (excluding projections) |
| Weight | Approx. 1.2kg |
| Measurement Method | Diffusion |
| Alarm Details | Gas alarm: Flashing red warning light Fault alarm: Flashing yellow warning light (used for sensor failure, voltage fault, etc.) |
| Display | LCD Digital LED Display |
| Connection Outputs | Gas concentration is transmitted via analogue signal; 4-20mA DC output available. |
| Power Supply | 24V DC (±20%) |
| Safety Classification | Ex d IIC T5 (TIIS) II 2 G ex db IIC T5 Gb (ATEX: Suitable for use in explosive atmospheres) Ex db IIC T5 Gb (IECEx) |
| Protection Class | IP65 Rating (Water and dust ingress protection level) |
| Applicable Cabling | Cable Outer Diameter: ø10-13 mm 5-core cable: CVV-S 1.25mm2 3-core cable: CVV-S 2mm2 or 1.25mm2 |
| Sensor Type | Catalytic Combustion Sensor |
|---|---|
| Detected Gas | Combustible/flammable gases, toxic gases |
| Detected Gas Range | According to Specifications |
| Alarm Accuracy | For Flammable Gases: ±25% of set alarm value For Toxic Gases: ±30% of set alarm value |
| Operating Temperature/Humidity | -100°C to +500°C, 10% - 90% Relative Humidity |
| Dimensions | 158 x 116 x 68 mm (excluding projections) |
| Weight | Approx. 1.2kg |
| Measurement Method | Diffusion |
| Alarm Details | Gas alarm: Flashing red warning light Fault alarm: Flashing yellow warning light (used for sensor failure, voltage fault, etc.) |
| Display | LCD Digital LED Display |
| Connection Outputs | Gas concentration is transmitted via analogue signal; 4-20mA DC output available. |
| Power Supply | 24V DC (±20%) |
| Safety Classification | Ex d IIC T5 (TIIS) II 2 G ex db IIC T5 Gb (ATEX: Suitable for use in explosive atmospheres) Ex db IIC T5 Gb (IECEx) |
| Protection Class | IP65 Rating (Water and dust ingress protection level) |
| Applicable Cabling | Cable Outer Diameter: ø10-13 mm 5-core cable: CVV-S 1.25mm2 3-core cable: CVV-S 2mm2 or 1.25mm2 |
| Sensor Type | Thermal Conductivity |
|---|---|
| Detected Gas | Hydrogen (H2), Helium (He), Carbon Dioxide (CO2) |
| Detected Gas Range | According to Specifications |
| Alarm Accuracy | For Flammable Gases: ±25% of set alarm value For Toxic Gases: ±30% of set alarm value |
| Operating Temperature/Humidity | -100°C to +500°C, 10% - 90% Relative Humidity |
| Dimensions | 158 x 116 x 68 mm (excluding projections) |
| Weight | Approx. 1.2kg |
| Measurement Method | Diffusion |
| Alarm Details | Gas alarm: Flashing red warning light Fault alarm: Flashing yellow warning light (used for sensor failure, voltage fault, etc.) |
| Display | LCD Digital LED Display |
| Connection Outputs | Gas concentration is transmitted via analogue signal; 4-20mA DC output available. |
| Power Supply | 24V DC (±20%) |
| Safety Classification | Ex d IIC T5 (TIIS) II 2 G ex db IIC T5 Gb (ATEX: Suitable for use in explosive atmospheres) Ex db IIC T5 Gb (IECEx) |
| Protection Class | IP65 Rating (Water and dust ingress protection level) |
| Applicable Cabling | Cable Outer Diameter: ø10-13 mm 5-core cable: CVV-S 1.25mm2 3-core cable: CVV-S 2mm2 or 1.25mm2 |
| Sensor Type | Non-dispersive Infrared Sensor |
|---|---|
| Detected Gas | Methane (CH4), Carbon Dioxide (CO2) |
| Detected Gas Range | According to Specifications |
| Alarm Accuracy | ±25% of set alarm value |
| Operating Temperature/Humidity | -100°C to +500°C, 10% - 90% Relative Humidity |
| Dimensions | 158 x 120 x 68 mm (excluding projections) |
| Weight | Approx. 1.3kg |
| Measurement Method | Diffusion |
| Alarm Details | Gas alarm: Flashing red warning light Fault alarm: Flashing yellow warning light (used for sensor failure, voltage fault, etc.) |
| Display | LCD Digital LED Display |
| Connection Outputs | Gas concentration is transmitted via analogue signal; 4-20mA DC output available. |
| Power Supply | 24V DC (±20%) |
| Safety Classification | Ex d IIC T5 (TIIS) II 2 G ex db IIC T5 Gb (ATEX: Suitable for use in explosive atmospheres) Ex db IIC T5 Gb (IECEx) |
| Protection Class | IP65 Rating (Water and dust ingress protection level) |
| Applicable Cabling | Cable Outer Diameter: ø10-13 mm 5-core cable: CVV-S 1.25mm2 3-core cable: CVV-S 2mm2 or 1.25mm2 |
| Sensor Type | Electrochemical Sensor |
|---|---|
| Detected Gas | Carbon monoxide (CO) Hydrogen Sulphide (H2S) |
| Detected Gas Range | For Carbon Monoxide (CO): 0-100ppm, 0-150ppm or 0-250ppm Hydrogen Sulphide (H2For S): 0-30ppm or 0-50ppm |
| Alarm Accuracy | ±30% of set alarm value |
| Operating Temperature/Humidity | -100°C to +400°C, 30% - 85% Relative Humidity |
| Dimensions | 158 x 120 x 68 mm (excluding projections) |
| Weight | Approx. 1.3kg |
| Measurement Method | Diffusion |
| Alarm Details | Gas alarm: Flashing red warning light Fault alarm: Flashing yellow warning light (used for sensor failure, voltage fault, etc.) |
| Display | LCD Digital LED Display |
| Connection Outputs | Gas concentration is transmitted via analogue signal; 4-20mA DC output available. |
| Power Supply | 24V DC (±20%) |
| Safety Classification | Ex d IIC T5 (TIIS) II 2 G ex db IIC T5 Gb (ATEX: Suitable for use in explosive atmospheres) Ex db IIC T5 Gb (IECEx) |
| Protection Class | IP65 Rating (Water and dust ingress protection level) |
| Applicable Cabling | Cable Outer Diameter: ø10-13 mm 5-core cable: CVV-S 1.25mm2 3-core cable: CVV-S 2mm2 or 1.25mm2 |
| Sensor Type | Galvanic Sensor |
|---|---|
| Detected Gas | Oxygen (O2) |
| Detected Gas Range | 0-25 %vol |
| Alarm Accuracy | ±1.0 %vol of set alarm value |
| Operating Temperature/Humidity | 00°C to +400°C, 30% - 85% Relative Humidity |
| Dimensions | 158 x 120 x 68 mm (excluding projections) |
| Weight | Approx. 1.3kg |
| Measurement Method | Diffusion |
| Alarm Details | Gas alarm: Flashing red warning light Fault alarm: Flashing yellow warning light (used for sensor failure, voltage fault, etc.) |
| Display | LCD Digital LED Display |
| Connection Outputs | Gas concentration is transmitted via analogue signal; 4-20mA DC output available. |
| Power Supply | 24V DC (±20%) |
| Safety Classification | Ex d IIC T5 (TIIS) II 2 G ex db IIC T5 Gb (ATEX: Suitable for use in explosive atmospheres) Ex db IIC T5 Gb (IECEx) |
| Protection Class | IP65 Rating (Water and dust ingress protection level) |
| Applicable Cabling | Cable Outer Diameter: ø10-13 mm 5-core cable: CVV-S 1.25mm2 3-core cable: CVV-S 2mm2 or 1.25mm2 |
Practical, Compact, Lightweight, and Robust Construction
Compared to similar products, the KD-12 is more compact and lightweight, while taking up very little space. This ensures no difficulties in positioning the device during installation. Furthermore, its rugged construction ensures resistance to ambient conditions. Its bright digital LED display allows gas concentrations and alarm indicators to be read easily.
Explosion-proof Construction (Ex-proof), HART, SIL2 Certifications
The product design and the gas sensor—the most critical component of gas systems—are produced in Japan, distinguished by high quality and reliability.
Simple and Cost-Effective Installation
Sensor replacement is extremely straightforward; calibration and other procedures can be carried out by a single person. The easy-to-read display simplifies the technician's task during calibration.
Use in Any Environment with IP65 Protection Rating
In addition to its rugged construction, the device features an IP rating and is resistant to dust and water splashes. It is not easily affected by rain or external factors.
Solution for All Gas Requirements with Sensor Variety
It features models supporting a wide range of sensor types, primarily combustible gases, toxic gases and oxygen. Delivering multiple sensor options in a single instrument, it provides both an economical and flexible solution.
Adaptability to Diverse Operating Applications
It can be used in diverse application areas such as manufacturing facilities, fuel handling environments, wastewater treatment plants, refineries, pipelines, tanks and power stations. It can also be installed on mobile objects such as road tankers and vehicles.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.