Customer need
Maintenance and survey work require a measurement method and range suitable for the gas encountered.
NOVEL · Product and System Solutions
Gas Detectors and Industrial Measurement Instruments

The New Cosmos XP-704III is a portable leak detector with pumped (extractive) sampling designed for rapid detection of refrigerant gas leaks. It provides an audible/visual alarm upon leak detection; as the leak intensifies, the alarm frequency increases, switching to a continuous alarm at high levels. The XP-704III is used to detect leaks of the following refrigerant gases: R-22, R-32, R-404A, R-407C, R-600a, R-410A, R-134a, R-290, HFO-1234yf.
From need to solution
New Cosmos XP-704III Refrigerant Gas Leak Detector: selection starts with the measurement or system output your team needs for its decision.
Maintenance and survey work require a measurement method and range suitable for the gas encountered.
Readings and alarm indications from the fitted sensors help assess conditions at the inspection point.
Plan screening, closer investigation and repeat measurements, with pre-use checks and site procedures as part of the measurement process.
| Model | XP-704 III |
|---|---|
| Detected Gas | R-22, R-32, R-404A, R-407C, R600a, R410A, R-134a, R-290, HFO-1234yf |
| Detection Principle | Hot-Wire Semiconductor Sensor |
| Sampling Method | Suction Type |
| Minimum Detectable Leak Rate (g/Year) | R-22: 2.84(g), R-32: 1.71(g), R-404A: 3.30(g), R-407C: 3.12(g), R600a: 1.91(g), R410A: 2.82(g), R-134a: 20.09(g), R-290: 1.45(g), HFO-1234yf: 3.74(g) |
| Minimum Detectable Gas Concentration | 5 ppm (R-134a: 30ppm) |
| Response Time | within 10 seconds |
| Power Supply / Battery Life | AA alkaline battery x 2 - Continuous 12-hour operating time |
| Certificates | IP22, CE Marking |
| Operating Pressure | Atmospheric Pressure (800 to 1100 hPa) |
| Operating Temperature / Humidity | 0 to +40 °C, 85%RH humidity and below (non-condensing) |
| Dimensions and Weight | 38mm x 130mm x 32mm + Approx. 190g (including case and battery) |
| Standard Accessories | Soft Case, Drain Filter, Dust Filter, Gas probe, Hose, Hand Strap, 2x AA alkaline battery, User Manual |
Sensitivity Levels (practical site description): The XP-704III features 5 sensitivity levels. Level 5: For detecting very low concentrations (5 ppm and below; 30 ppm and below for R-134a). Level 4: Around 30 ppm (approx. 100 ppm for R-134a). Lower sensitivities (3–1) provide practical operation where environmental interference may be high and for more pronounced leaks.
The XP-704III is used to rapidly and easily detect HCFC and HFC gases hazardous to human health and the environment: R-22, R-32, R-404A, R-407C, R-600a, R-410A, R-134a, R-290, HFO-1234yf.
Alarm frequency increases as the leak is approached; provides a continuous alarm at very high levels (facilitates pinpointing leaks).
Automatic gas purge operates if gas remains in the instrument upon switch-off (countdown on LCD)
Box contents: Instrument (with soft case), DF-114 drain filter, FE-2 spare filter element, AT-2G probe, FE-106 dust filter, EG-10 check gas, hand strap, 2x AA alkaline batteries, instruction manual, etc.
Options (available separately): AT-6 / AT-7A gas collectors, RP-4 telescopic probe, ATS-6 gas collection set, etc.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.