NOVEL · Products and system solutions

ZEFON Filter Cassette Housings and Sampling Media

ZEFON Filter Cassette Housings and Sampling Media

Product Overview

Choose preloaded or empty cassettes by diameter, construction, material, sampler connection and analytical method. Compare clear 37MMH-3 three-piece housings with other configurations.

Request a Quote from NOVEL ↗

Cassette Designs and Applications

37MMH-3 — 37 mm, three-piece

37MMH-3 — 37 mm, three-piece

Clear styrene housing with spacer ring, offering method-dependent open/closed-face use and compatible cyclone connections. Select filter and pad separately; 50 per box.

37MMH-2 — 37 mm, two-piece

37MMH-2 — 37 mm, two-piece

Compact clear styrene housing for closed-face use, with less internal surface area than a three-piece design. Do not assume compatibility with samplers requiring a spacer ring; 50 per box.

37MMH-3-CF — conductive housing

37MMH-3-CF — conductive housing

Black conductive 37 mm three-piece construction for methods requiring control of electrostatic effects. Conductivity does not remove the need to account for internal deposits; 50 per box.

Air-O-Cell — bioaerosol cassette

Air-O-Cell — bioaerosol cassette

Collects spores and other airborne particles on a specialised collection surface. Its purpose differs from a general gravimetric dust cassette and requires appropriate laboratory counting.

Empty Housing or Preloaded Cassette?

When is an empty housing useful?

Empty housings suit laboratory conditioning, pre-weighing, pretreatment or alternative media. Specify membrane, backing pad, plugs and sealing band separately.

When is preloaded media useful?

A manufacturer-assembled cassette simplifies field preparation. Its membrane material, pore size, diameter, number of pieces and any pre-weighing must still match the method and part number.

Material and inlet configuration

Clear housings permit visual checks; conductive, opaque or chemically resistant materials serve specific needs. Open-face, closed-face and four-piece central filter placement are not arbitrary substitutes.

How Is a Filter Installed in a Cassette?

  1. Prepare a clean area. Check housing diameter, filter method and any pre-weighing record.
  2. Using clean forceps, place the specified backing pad in the outlet base and the membrane upstream of it. Do not touch the collection surface.
  3. Keep the filter edge flat on its seating surface. Assemble ring and inlet in the manufacturer’s specified open/closed-face configuration.
  4. Use a compatible closure and sealing band, perform the appropriate leak check and set flow through the assembled train.
  5. Identify sample and flow direction. After sampling, cap ports and follow laboratory transport/storage instructions; confirm how internal wall deposits are included in analysis.

Select by Part Number and Specification

Empty housings, dimensions and part numbers →Preloaded cassettes →Filter material selection guide →

Manufacturer and Technical Sources

Related Technical Documents

NOVEL

Choose the right solution for your application.

Request a Quote from NOVEL ↗