NOVEL · Product and System Solutions

New Cosmos XP-702III Series

Gas Detectors and Industrial Measurement Instruments

New Cosmos XP-702III Series product image

Handheld flammable gas leak detector, dedicated design for gas distribution utilities and industry, dedicated version for CFC refrigerant gases

Request Technical Archive Support ↗



Product Specifications
  • Pinpoint detection of gas leaks

  • Reduced dimensions and lighter weight

  • Trouble-free operation even in the harshest field conditions

  • Highly visible illuminated and audible alarm

  • Manufactured by New Cosmos, the world's leading sensor manufacturer

  • Fast response and high sensitivity even at very low concentrations

  • Product Documents

    Technical Specifications

    XP-702III-A

    Technical Specifications

    Detected Gas Two types of flammable/combustible gas (selectable)
    Sensor Type Hot-Wire Semiconductor Sensor
    Minimum detectable gas volume Natural gas, LPG, etc.: 3.3x10-6Pa.m3/S
    CFC refrigerant gases: R-407C, leak rate: 12.4g/year; R-410A, leak rate: 11.2g/year
    Minimum detectable gas concentration Natural gas, LPG, etc.: 10ppm; CFC: 30ppm
    Response time 3s or less (excluding CFC)
    Alarm warning Audible and visual indication
    Power Supply 2 x AA alkaline batteries
    Battery Life*1 12 hours operating time (with alkaline batteries)
    Safety Classification*2 Ex ia II BT3 ATEX (suitable for use in potentially explosive atmospheres)
    Operating Temperature/Humidity -20o°C to +50o°C, between 30% and 85% Relative Humidity
    Dimensions 38 x 130 x 32 mm
    Weight ~190g (including battery and carrying case)
    Standard Accessories*3 Carrying case, probe, filter, hand strap, 2 x AA alkaline batteries
    Optional Accessories*4 Copper pipe, gas collector, sampling hose, etc.
    *1 Battery life may vary depending on ambient conditions, operating conditions, storage, etc.
    *2 Applies when the detector is inside the carrying case.
    *3 Standard accessories may vary according to instrument specifications.
    *4 Please enquire for details.
    XP-702III-B
    Detected Gas Single type of flammable/combustible gas (natural gas, LPG, etc.)
    Sensor Type Hot-Wire Semiconductor Sensor
    Minimum detectable gas volume Natural gas, LPG, etc.: 3.3x10-6Pa.m3/S
    CFC refrigerant gases: R-407C, leak rate: 12.4g/year; R-410A, leak rate: 11.2g/year
    Minimum detectable gas concentration Natural gas, LPG, etc.: 10ppm; CFC: 30ppm
    Response time 3s or less (excluding CFC)
    Alarm warning Audible and visual indication
    Power Supply 2 x AA alkaline batteries
    Battery Life*1 12 hours operating time (with alkaline batteries)
    Safety Classification*2 Ex ia II BT3 ATEX (suitable for use in potentially explosive atmospheres)
    Operating Temperature/Humidity -20o°C to +50o°C, between 30% and 85% Relative Humidity
    Dimensions 38 x 130 x 32 mm
    Weight ~190g (including battery and carrying case)
    Standard Accessories*3 Carrying case, probe, filter, hand strap, 2 x AA alkaline batteries
    Optional Accessories*4 Copper pipe, gas collector, sampling hose, etc.
    *1 Battery life may vary depending on ambient conditions, operating conditions, storage, etc.
    *2 Applies when the detector is inside the carrying case.
    *3 Standard accessories may vary according to instrument specifications.
    *4 Please enquire for details.
    XP-702III-F
    Detected Gas CFC gases and flammable/combustible gas (selectable)
    Sensor Type Hot-Wire Semiconductor Sensor
    Minimum detectable gas volume Natural gas, LPG, etc.: 3.3x10-6Pa.m3/S
    CFC refrigerant gases: R-407C, leak rate: 12.4g/year; R-410A, leak rate: 11.2g/year
    Minimum detectable gas concentration Natural gas, LPG, etc.: 10ppm; CFC: 30ppm
    Response time 3s or less (excluding CFC)
    Alarm warning Audible and visual indication
    Power Supply 2 x AA alkaline batteries
    Battery Life*1 12 hours operating time (with alkaline batteries)
    Safety Classification*2 Ex ia II BT3 ATEX (suitable for use in potentially explosive atmospheres)
    Operating Temperature/Humidity -20o°C to +50o°C, between 30% and 85% Relative Humidity
    Dimensions 38 x 130 x 32 mm
    Weight ~190g (including battery and carrying case)
    Standard Accessories*3 Carrying case, probe, filter, hand strap, 2 x AA alkaline batteries
    Optional Accessories*4 Copper pipe, gas collector, sampling hose, etc.
    *1 Battery life may vary depending on ambient conditions, operating conditions, storage, etc.
    *2 Applies when the detector is inside the carrying case.
    *3 Standard accessories may vary according to instrument specifications.
    *4 Please enquire for details.

    Gas Detection and Standards Approach

    Gas detection approach: Gas type, target measuring range, alarm objective, sampling/diffusion method, sensor principle, and site atmosphere should be evaluated together. In flammable gas and explosive atmosphere applications, the EN/IEC 60079 series and relevant gas detection performance standards should be considered on an application-specific basis. These statements do not imply that the model is certified to all standards; exact compliance must be confirmed separately according to model code, target gas, and certificate version.

    Sectors

    Alternative Products

    You can examine product details and technical specifications by selecting an alternative suited to your requirements.

    Notice: The technical information, product specifications and images on this page are based on manufacturer publications. The manufacturer may change specifications without notice. For current specifications or assistance in selecting a suitable product for your application, please contact NOVEL at Request Technical Archive Support ↗ .

    NOVEL technical support

    For your application,
    let us select the right solution together.

    Request Technical Archive Support ↗

    A draft opens in your email client with the subject header of the relevant product or category.