Customer need
Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

The CEL-246 is a compact Class 2 sound level meter developed for general workplace noise measurements, walk-through field surveys, product noise, and alarm checks. In addition to instantaneous and maximum sound pressure levels, it measures Leq or Lavg average values; with a graphical time history and internal data logging, it facilitates the assessment of fluctuating noise.
From need to solution
TSI Casella CEL-246 Sound Level Meter: selection starts with the measurement or system output your team needs for its decision.
Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.
Sound-level, exposure or analysis indicators supported by the chosen model are recorded with the field conditions.
Prioritise sources, further measurements and controls, distinguishing the role of a dosimeter from a sound-level meter and checking acoustic calibration requirements.
Technical Specifications
| Standards | IEC 61672-1:2002 Class 2; IEC 60651:1979 Type 2; ANSI S1.4 Type 2A; for CEL-246 IEC 60804:2000 Type 2 and ANSI S1.43:1997 (R2007) Type 2 |
|---|---|
| Measurement Range | 30–130 dB(A) RMS; selectable 30–100 dB and 60–130 dB ranges |
| Noise Floor | Typically <33 dB(A) |
| Frequency Weightings | A and C |
| Time Weightings | Fast, Slow, and Impulse |
| Average Measurement | Leq (Q=3) or Lavg (Q=5) |
| Logging Interval | CEL-246: selectable 1–10 second average value |
| Memory | 419,000 data points; 100 runs; maximum 65,515 data points per run |
| File Format | .CSV; compatible with spreadsheet applications |
| Calibration | 1 kHz @ 94 or 114 dB auto-calibration sensing; CEL-120/1 or CEL-120/2 |
| Display | 128 × 128 monochrome graphic LCD; 0.5 s update |
| Connectivity | USB 2.0 Mini-B; auxiliary 2.5 mm stereo socket |
| Battery / Operating Time | 3 × AA alkaline or NiMH; typical / greater than 35 hours |
| Operating Conditions | 0–40 °C; 5–90% RH non-condensing; 65–108 kPa |
| Dimensions / Weight | 72 × 212 × 31 mm / 245 g (including batteries) |
| Class 2 Instrument Standard | IEC 61672-1:2002 Class 2; also IEC 60651 Type 2 and ANSI S1.4 Type 2A. The average/integrating functions of the CEL-246 are covered under IEC 60804 Type 2 and ANSI S1.43 Type 2. |
|---|---|
| Workplace Noise Measurement | The CEL-246 can be used for LAeq-based measurements in workplace area surveys, determining noise levels around tasks or sources, and general occupational hygiene noise assessments. When determining personal daily exposure, a shoulder-worn personal dosimeter may be required depending on the measurement strategy. |
| Leq and Peak Methodology | The CEL-246 measures Leq/Lavg, instantaneous, and maximum levels. It features A and C frequency weightings. Because Z weighting is not specified in the instrument's technical documentation, no Z or LCpeak measurement capability is claimed on this page. |
| Field Calibration | The manufacturer recommends acoustic calibration before and after measurement using a CEL-120/2 or CEL-120/1. The instrument automatically senses the calibrator signal at 94 or 114 dB at 1 kHz. |
| Raw Data and Traceability | The CEL-246 can store 419,000 data points and 100 runs in internal memory. With a selectable logging interval of 1–10 seconds, time-history data can be exported to a PC in CSV format. |
| Implementation in Turkey | In occupational hygiene measurements, instrument class alone is not sufficient; measurement strategy, valid calibration of the instrument, pre/post-field verification, measurement positioning, and reporting must be implemented together in accordance with applicable legislation, TS EN ISO 9612, and authorised laboratory procedures. |
IEC 61672-1 Class 2: compliance with IEC 61672-1:2002 Class 2, IEC 60651 Type 2, and ANSI S1.4 Type 2A is specified in manufacturer technical documentation; integrating average functions are further covered under IEC 60804 Type 2 and ANSI S1.43 Type 2.
Leq / Lavg average measurement: Energy equivalent Leq (Q=3) can be selected for European-based applications, and Lavg (Q=5) for US-based applications.
30–130 dB measurement: Selectable 30–100 dB and 60–130 dB ranges; A and C frequency weightings with Fast, Slow, and Impulse time weightings.
Time history and logging: The CEL-246 logs up to 419,000 data points with a selectable 1–10 second logging interval; 100 separate runs can be stored, and CSV data can be downloaded to a PC.
Field calibration: Automatically senses the 1 kHz, 94 or 114 dB signal of a CEL-120/1 or Class 2 CEL-120/2 acoustic calibrator. The manufacturer recommends acoustic calibration verification before and after measurement.
Practical field use: high-resolution graphic display, two softkeys, approx. 35 hours battery life, USB connectivity, and a compact 245 g body.
You can compare other noise measurement solutions based on measurement class, level of analysis, and personal exposure requirements.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.