Customer need
Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

The TSI Casella CEL-630 Series is a family of professional logging sound level meters developed for advanced workplace and environmental noise measurements. The CEL-632 and CEL-633 models simultaneously log broadband parameters in a single measurement range, and depending on the model, offer real-time 1/1 and 1/3 octave analysis, audio recording, event capture, and statistical assessment.
From need to solution
TSI Casella CEL-630 Series Sound Level Meter and Analyser: selection starts with the measurement or system output your team needs for its decision.
Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.
Sound-level, exposure or analysis indicators supported by the chosen model are recorded with the field conditions.
Prioritise sources, further measurements and controls, distinguishing the role of a dosimeter from a sound-level meter and checking acoustic calibration requirements.

Technical Specifications
| Series / Models | CEL-632 and CEL-633; A, B, C analysis options; Class 1 or Class 2 |
|---|---|
| Standards | IEC 61672:2002 Class 1 and 2; ANSI S1.4 Type 1 and 2 |
| Frequency Filters | IEC 61260 Class 0; ANSI S1.43 (1996) |
| Measurement Range | 20–140 dB RMS; 143.3 dB peak |
| Noise Floor | 19 dB(A) Class 1; 25 dB(A) Class 2 |
| Frequency Weightings | A, C, and Z simultaneous |
| Time Weightings | Fast, Slow, and Impulse simultaneous |
| Q Exchange Rate | 3, 4, and 5 simultaneous |
| 1/1 Octave | 11 bands, 16 Hz–16 kHz (B and C models) |
| 1/3 Octave | 33 bands, 12.5 Hz–20 kHz (C models) |
| Broadband Parameters | LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq, LTM3, LTM5, LAE |
| Back Erase | Last 10 seconds in Cumulative mode |
| Memory | 2 GB; >1 year with 1 s logging; 999 runs |
| Audio | Up to 10 hours at high quality / 60 hours at low quality |
| Battery | 3 × AA alkaline; approx. 10–15 hours depending on backlight |
| Dimensions / Weight | 230 × 72 × 31 mm / 332 g (including batteries) |
| Operating Conditions | Class 1: -10…+50 °C; Class 2: 0…40 °C; 0–90% RH non-condensing; 65–108 kPa |
| Function | CEL-632 | CEL-633 |
|---|---|---|
| Cumulative / Period / Profile | ✓ | ✓ |
| Audio Voice Notes / Marker Events | ✓ | ✓ |
| Statistical Ln% | — | ✓ |
| Level-triggered Events | — | ✓ |
| A option | Broadband | Broadband |
| B option | Broadband + 1/1 octave | Broadband + 1/1 octave |
| C option | Broadband + 1/1 + 1/3 octave | Broadband + 1/1 + 1/3 octave |
Class 1 or Class 2: IEC 61672:2002 Class 1 and Class 2 options; ANSI S1.4 Type 1/2. Frequency filters are defined according to IEC 61260 Class 0 requirements.
20–140 dB single measurement range: 20–140 dB RMS and 143.3 dB peak; wide dynamic range without manual range switching using standard microphones. Applications up to 165 dB can be supported with an optional high-range microphone.
Simultaneous A, C, and Z: A, C, and Z frequency weightings along with Fast, Slow, and Impulse time weightings can be measured simultaneously; exchange rates of Q=3, 4, and 5 are supported.
1/1 and 1/3 octave: 11 1/1-octave bands between 16 Hz–16 kHz on B and C models; C models additionally feature 33 1/3-octave bands between 12.5 Hz–20 kHz.
2 GB memory and time-history: More than one year of data capacity at 1-second logging interval, 999 measurement runs, period/profile results, and detailed analysis via Casella Insight.
Audio and event recording: Noise sources can be identified via voice notes and WAV recording. The CEL-633 provides further advanced analysis for environmental measurements with level-triggered event recording and statistical Ln values.
CEL-120 calibration integration: Field calibration dates and times can be stored alongside measurement data and transferred to Insight software.
You can compare other professional noise measurement solutions according to measurement class, analysis level, and personal exposure requirements.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.