Customer need
The same mask does not fit every face equally; the wearer, model and size combination needs assessment.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments
TSI PortaCount 8040 and 8048 quantify the fit of a tight-fitting respirator to the wearer’s face. Model 8040 is intended for respirators with filter efficiency of at least 99%; Model 8048 adds N95-Companion technology for lower-efficiency filtering facepieces, including N95, FFP2 and FFP1. Select the appropriate test adapter and protocol for the respirator and application.
From need to solution
TSI PortaCount™ 8040 and 8048: selection starts with the measurement or system output your team needs for its decision.
The same mask does not fit every face equally; the wearer, model and size combination needs assessment.
Quantitative fit testing provides a fit factor and test record for the selected mask and protocol, subject to the instrument’s supported mask classes.
Support mask selection and donning training with measured evidence; fit testing does not replace filter selection, maintenance or the rest of a respiratory-protection programme.
PortaCount measures the ratio of ambient to in-mask particle concentration while the wearer performs a fit-test exercise sequence. It assesses the fit of a tight-fitting respirator on that wearer; it is not a filter-efficiency or breathing-air analyser.
Elastomeric half/full-face respirators with ≥99% efficient filters, N99/N100 and FFP3 filtering facepieces.
Adds N95, FFP2 and FFP1 testing with N95-Companion technology. Choose the appropriate protocol and adapter for each mask.
FitCheck Mode visualises the effect of mask adjustment; it supports training before the formal test.
FitPro Ultra manages exercise sequences, wearer/respirator records and reports. Use a supported computer and the current software requirements.
Carry out particle, zero and maximum fit-factor checks. Use the correct twin tubing, sampling adapter and reagent-grade isopropyl alcohol.
PortaCount fit-test programmes use a dedicated TSI Link for Respiratory Protection service for programme records, reporting and API integration. It uses a separate portal from environmental air monitoring. Confirm compatible instrument software and subscription scope for the selected workflow. Open Respiratory Protection Portal ↗ · Manufacturer Software Information ↗
| Parameter | 8040 | 8048 |
|---|---|---|
| Mask coverage | Elastomeric half/full-face respirators with ≥99% efficient filters, N99/N100 and FFP3 filtering facepieces. | Adds N95, FFP2 and FFP1 testing with N95-Companion technology. Choose the appropriate protocol and adapter for each mask. |
| Fit-factor range | 1–>10,000 | 1–>10,000; 1–200 for <99% efficient respirators |
| Measurement principle | Ambient aerosol condensation particle counting; Cout/Cin | Same principle with N95-Companion selection |
| Particle size | 0.02–>1 µm | 0.02–>1 µm |
| Concentration range | 0.01–250,000 particles/cm³ | 0.01–250,000 particles/cm³ |
| Sampling / total flow | 350 / 1,000 cm³/min (nominal total) | 350 / 1,000 cm³/min (nominal total) |
| Operating temperature | 0–35 °C | 0–35 °C |
| Instrument weight | ≤2.3 kg | ≤3.1 kg |
| Connections | Wi-Fi, USB-C, USB-A | Wi-Fi, USB-C, USB-A |
| Alcohol | ≥99.5% isopropyl alcohol | ≥99.5% isopropyl alcohol |
A PC/tablet is not included with the base 8048; the 8048-T kit includes a tablet. N95-Companion is integrated in 8048. Manufacturer manual and reorder list ↗
Select accessories for the exact instrument, method and operating range. Kit contents vary; replacement consumables and optional items are identified below.

8016
Manufacturer consumable for the PortaCount alcohol system. Follow the specified alcohol purity and filling procedure.

8033
Replacement consumable for the 8040/8048 alcohol cartridge; service according to instrument checks and the manual.

803X-ZFLTR
Used for the daily instrument zero check; this is not a respirator filter.

8017
Twin tubing and connection adapters for replacing damaged or contaminated sampling lines.

8025-N95R
Probes and push nuts for mask sampling connections; use the correct insertion tool and facepiece procedure.

803011
NaCl consumable for the 8026 particle generator; do not add it to the PortaCount alcohol reservoir.

800197
Replacement twin tubing for 8040/8048 sampling; retain the specified connection and length.

8034
Manufacturer-listed power supply for 803x/804x instruments; confirm the instrument and mains configuration.

8032-CT
Replaceable alcohol-system cartridge. Wicks, storage cap and fill capsule are separate parts.

8032-SC
Replacement cap for storing the alcohol cartridge between measurements.

801561
Reservoir for the 8026 particle generator; different from the PortaCount alcohol fill capsule.
8026 / maske adaptörü
The current manufacturer 8048 package includes an 8026 and probing kit; check the delivered kit before reordering. Reusable respirators require the correct brand/model fit-test adapter.
8032
Manufacturer kit for replacing the cartridge and fill capsule together.
8032-FC
Capped capsule for preparing the cartridge according to the manual.
WF-USBD
Connectivity adapter listed in the manual; confirm compatibility with the computer/network setup.
8025-N95
Kit for inserting a sampling probe into a filtering facepiece. Refill consumable 8025-N95R is listed separately.
804004
USB hub listed for the manufacturer computer-connection arrangement.
804005
Replacement/optional extension cable for the computer connection.
Review the measurement task and related solutions for your operating environment.
These products are listed not as direct alternatives performing the identical function to PortaCount, but as complementary TSI solutions that can be utilised in occupational hygiene and exposure assessments.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.