Customer need
Knowing which tasks cause dust increases helps target workplace controls.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

From need to solution
TSI SidePak™ AM520 and AM520i: selection starts with the measurement or system output your team needs for its decision.
Knowing which tasks cause dust increases helps target workplace controls.
The wearable instrument’s supported particle indications and records make task-related changes visible.
Investigate tasks with elevated indications and compare controls; plan appropriate filter sampling and laboratory analysis where substance-specific exposure assessment is needed.
SidePak AM520 and AM520i are wearable, battery-powered laser photometers for following aerosol mass concentration in the breathing zone. They log one selected particle fraction at a time and help identify exposure peaks and the effect of engineering controls.
Standard personal aerosol monitor with model-specific battery and accessories.
Intrinsically safe version. Use only the approved battery/accessories and follow the certificate conditions for the intended hazardous location.
Select PM1, PM2.5, PM5 or PM10 impactors, a PM4 Dorr-Oliver cyclone or the 0.8 µm DPM cyclone. Each inlet requires its specified calibrated flow.
Mass and response concentration can be displayed/logged together. Audible/visual and STEL alarms support investigation of short peaks.
Ten named calibration factors can be managed with TrakPro v5. Relate the factor to gravimetric or laboratory reference results for the aerosol.
| Parameter | AM520 / AM520i |
|---|---|
| Mass concentration | 0.001–100 mg/m³ |
| Particle size range | 0.1–10 µm |
| Minimum resolution | 0.001 mg/m³ |
| Flow setting | 0–1.8 L/min; upper limit depends on the inlet/cyclone |
| Display time constant | 1–60 s |
| Logging interval | 1 s–60 min |
| Memory | Approximately 80,000 records; 55 days at 1 minute |
| Operating conditions | 0–50 °C; 0–95% RH (non-condensing) |
| Model batteries | AM520: 803300 / AM520i: 803322 |
| Software / connection | TrakPro v5 / USB 2.0 Micro-B |
| AM520i hazardous-area version | ATEX / IECEx / CSA; Ex ia IIC T4 Ga — check the full current certificate and conditions |
Accessories, consumables and replacement parts listed by the manufacturer. This is not a standard package-content list. Please specify the instrument model and part number; compatibility and supply are confirmed for your configuration.

803301
AM520 / AM520i; specific battery restrictions apply
Size-fraction selection using the appropriate inlet.

801701
AM520 / AM520i; specific battery restrictions apply
Respirable cyclone; use the flow stated in the manual.

803303
AM520 / AM520i; specific battery restrictions apply
Cyclone kit for diesel particulate applications.

803306
AM520 / AM520i; specific battery restrictions apply
Field maintenance parts including inlet seals.

801703
AM520 / AM520i; specific battery restrictions apply
Conductive Tygon tubing for personal sampling.

800663
AM520 / AM520i; specific battery restrictions apply
Filter for the instrument zero check.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.