Customer need
Converting collected mass to airborne concentration requires the sampling flow to be known.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

From need to solution
TSI 4146: selection starts with the measurement or system output your team needs for its decision.
Converting collected mass to airborne concentration requires the sampling flow to be known.
A flow calibrator provides a measurement for checking the assembled sampling train and comparing pump settings.
Record pre- and post-sampling checks and select a calibrator for the required flow range, connections and uncertainty.
With its compact and portable design, the TSI 4146 Flow Calibrator is extremely lightweight and easy to use. The low-flow volumetric flow rate is displayed live on screen, allowing you to make instant adjustments to pump flow. Air sampling pumps are key elements in exposure assessment studies. The accuracy of air pump sampling depends on how well the sampling pump performs and how properly the laboratory analysis is conducted. Sampling pumps must be calibrated with a calibration instrument before and after operation. With its compact and portable design, the TSI 4146 Flow Calibrator is extremely lightweight and easy to use. The low-flow volumetric flow rate is displayed live on screen, allowing you to make instant adjustments to pump flow. The TSI 4146 Flow Calibrator comes with a soft-case carry bag, battery pack, sampling tubing, user manual, and a NIST Traceable Calibration Certificate, and operates with an accuracy of +/- 2%. For accurate use, it requires calibration every 12 months.
| Model | TSI 4146 |
|---|---|
| Measurement Range | 0.01 - 20 litres/minute |
| Sensitivity | +/- %2 |
| Operating Temperature | Between 0 and 50 C |
| Storage Temperature | Between -20 and 60 C |
| Dimensions and Weight | 12.7 x 5 x 3.2 cm, 0.8 kg |
| Flow Body Material | Polycarbonate |
| Warm-up Time | 1 minute |
| Power Adaptor | 7.5V DC +-1.5V, 300mA maximum |
| Measurement Repeatability | +-%0.5 |
| Accessories | Carry case, dampening module, battery, rubber connection tubing, filter |
Real-Time Intervention Capability Provides real-time volumetric flow readings for air pumps, enabling quick and effortless adjustments and interventions to the pump
Design Providing Ease of Use Battery-operated, compact and lightweight design. Field-portable design. The TSI 4146 Flow Calibrator can be used to set, calibrate, and periodically check air pumps. Complete calibration kits are ready to use as soon as received, allowing calibration work to start immediately.
A Single Solution for Many Diverse Needs It can be used for sampling in environmental studies, indoor air quality measurements, and medical studies on disease distribution and control.
Reliable Operation The TSI 4146 Flow Calibrator comes with a NIST Traceable Calibration Certificate and operates with an accuracy of +/- 2%. In addition, the soft-case carry bag provides protection against water and dust as well as carrying convenience.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.