NOVEL · Product and System Solutions

TSI 4146

Occupational Safety and Environmental Measuring Instruments

TSI 4146 Air Flow Calibrator

Low Flow Air Calibrator for Occupational Hygiene (0.01-20 L/min)

Request a Quote from NOVEL ↗



With its compact and portable design, the TSI 4146 Flow Calibrator is extremely lightweight and easy to use. The low-flow volumetric flow rate is displayed live on screen, allowing you to make instant adjustments to pump flow. Air sampling pumps are key elements in exposure assessment studies. The accuracy of air pump sampling depends on how well the sampling pump performs and how properly the laboratory analysis is conducted. Sampling pumps must be calibrated with a calibration instrument before and after operation. With its compact and portable design, the TSI 4146 Flow Calibrator is extremely lightweight and easy to use. The low-flow volumetric flow rate is displayed live on screen, allowing you to make instant adjustments to pump flow. The TSI 4146 Flow Calibrator comes with a soft-case carry bag, battery pack, sampling tubing, user manual, and a NIST Traceable Calibration Certificate, and operates with an accuracy of +/- 2%. For accurate use, it requires calibration every 12 months.

Product Specifications
  • Real-Time Intervention Capability Provides real-time volumetric flow readings for air pumps, enabling quick and effortless adjustments and interventions to the pump

  • Design Providing Ease of Use Battery-operated, compact and lightweight design. Field-portable design. The TSI 4146 Flow Calibrator can be used to set, calibrate, and periodically check air pumps. Complete calibration kits are ready to use as soon as received, allowing calibration work to start immediately.

  • A Single Solution for Many Diverse Needs It can be used for sampling in environmental studies, indoor air quality measurements, and medical studies on disease distribution and control.

  • Reliable Operation The TSI 4146 Flow Calibrator comes with a NIST Traceable Calibration Certificate and operates with an accuracy of +/- 2%. In addition, the soft-case carry bag provides protection against water and dust as well as carrying convenience.

  • Product Documents

    Technical Specifications

    Show Technical Details
    Model TSI 4146
    Measurement Range 0.01 - 20 litres/minute
    Sensitivity +/- %2
    Operating Temperature Between 0 and 50 C
    Storage Temperature Between -20 and 60 C
    Dimensions and Weight 12.7 x 5 x 3.2 cm, 0.8 kg
    Flow Body Material Polycarbonate
    Warm-up Time 1 minute
    Power Adaptor 7.5V DC +-1.5V, 300mA maximum
    Measurement Repeatability +-%0.5
    Accessories Carry case, dampening module, battery, rubber connection tubing, filter

    Sampling and Standards Approach

    Flow verification approach: verifying the actual flow rate of air sampling pumps before and after sampling is a critical step for sample volume and the reliability of analytical findings. The operating range of the calibrator must cover the target pump flow rate, and where possible, the sampling train/media should be included in the system during calibration.

    Sectors

    Alternative Products

    You can examine product details and technical specifications by selecting an alternative suited to your requirements.

    Notice: The technical information, product specifications and images on this page are based on manufacturer publications. The manufacturer may change specifications without notice. For current specifications or assistance in selecting a suitable product for your application, please contact NOVEL at info@novel.com.tr .

    NOVEL technical support

    For your application,
    let us select the right solution together.

    Request a Quote from NOVEL ↗

    A draft opens in your email client with the subject header of the relevant product or category.