Customer need
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
NOVEL · Products and system solutions

EVM-3, EVM-4 and EVM-7 configurations for particles, CO₂, VOCs and optional toxic gases. Combine the appropriate sensors with temperature, humidity and logged field data.
Request a Quote from NOVEL ↗From need to solution
TSI EVM Series Air Quality and Aerosol Monitors: selection starts with the measurement or system output your team needs for its decision.
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
Parameters measured by the fitted sensors or probes are reviewed with their measurement location and time.
Plan ventilation adjustments, follow-up investigation and monitoring points; a single parameter or spot reading does not describe every aspect of air quality or health risk.

EVM-3 and EVM-7 use light scattering to monitor aerosol mass concentration. The rotary impactor selects PM₂.₅, PM₄, PM₁₀ or total particulate; these are not optical particle-counter size channels.

EVM-4 and EVM-7 provide NDIR CO₂; PID VOC and selected toxic gas sensors depend on configuration. PID results depend on calibration gas and the compound correction factor.

Use logged data to compare ventilation, process changes and work tasks. DMS supports instrument configuration, time-history review and reporting workflows.
The 90° light-scattering photometer has a stated aerosol size response of 0.1–10 µm. Optical response depends on material, density and refractive index. The integrated pump and suitable filter arrangement allow gravimetric sample collection to support site-specific interpretation.
CO₂ sensor range is 0–5,000 ppm. Temperature range is 0–60 °C, with 0–100% RH indication. Evaluate condensation, operating limits and accuracy using the relevant sensor specification.
The 10.6 eV PID screens VOCs with suitable ionisation energy and manufacturer response factors. PID and toxic gas options are optional on EVM-4; EVM-7 toxic gas capability depends on its configured sensor. A total VOC indication does not identify an individual chemical.
| Model | Particles | CO₂ | PID VOC | Toxic gas |
|---|---|---|---|---|
| EVM-3 | Yes | No | No | No |
| EVM-4 | No | Yes | Optional | Optional |
| EVM-7 | Yes | Yes | Yes | Optional |
All three models measure temperature and relative humidity. Not every instrument contains every sensor; confirm the target gas, range and installed options before ordering.
Accessories, consumables and replacement parts listed by the manufacturer. This is not a standard package-content list. Please specify the instrument model and part number; compatibility and supply are confirmed for your configuration.

074-720
EVM; depending on sensor and model configuration
Zero check for the aerosol channel on EVM-3/EVM-7.

074-090
EVM; depending on sensor and model configuration
Replacement pump-protection filters.

074-080
EVM; depending on sensor and model configuration
Cleaning kit for the PID on EVM-7; follow the service manual.

074-726
EVM; depending on sensor and model configuration
Use with the installed gas sensor and appropriate calibration system.

059-045
EVM; depending on sensor and model configuration
Tripod for fixed-point measurements.
Review the measurement task and related solutions for your operating environment.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL