Customer need
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
TSI AIRASSURE · CONTINUOUS INDOOR AIR QUALITY MONITORING
Three gas configurations. One continuous view of your indoor environment.
AirAssure 8144 monitors track gas and particle pollutants in offices, schools, hospitals, hotels and industrial buildings. All three models monitor CO₂, VOC, PM2.5, PM10, temperature, relative humidity and barometric pressure. Select 8144-4 when formaldehyde is required; choose 8144-6 for NO₂, SO₂ and ozone alongside CO. Follow conditions remotely with TSI Link.
Request a Quote from NOVEL ↗From need to solution
TSI AirAssure 8144-2 / 8144-4 / 8144-6 Indoor Air Quality Monitors: selection starts with the measurement or system output your team needs for its decision.
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
Parameters measured by the fitted sensors or probes are reviewed with their measurement location and time.
Plan ventilation adjustments, follow-up investigation and monitoring points; a single parameter or spot reading does not describe every aspect of air quality or health risk.
AIRASSURE 8144
The suffix -2, -4 or -6 identifies the gas configuration, not the total number of measured parameters.
2 GAS CHANNELS
CO₂ · VOC
Track baseline indoor trends, ventilation indicators and particle changes.
PM2.5 · PM10 · Temperature · RH · Pressure
Request a Quote ↗4 GAS CHANNELS
CO₂ · VOC · CO · H₂CO
For indoor assessments that require formaldehyde and carbon monoxide monitoring.
PM2.5 · PM10 · Temperature · RH · Pressure
Request a Quote ↗6 GAS CHANNELS
CO₂ · VOC · CO · NO₂ · SO₂ · O₃
Track combustion gases and the impact of outdoor pollutants on indoor conditions.
PM2.5 · PM10 · Temperature · RH · Pressure
Request a Quote ↗Formaldehyde (H₂CO) is available on 8144-4 only. Model 8144-6 does not include a formaldehyde channel.
TSI LINK
AirAssure monitors send readings to TSI Link over 2.4 GHz Wi-Fi. Compare current and historical indoor conditions across multiple locations, manage alerts and share selected data. Premium software and API Data Services are plan-dependent services; confirm the subscription term and enabled functions in your quotation. The supplied MicroSD card provides local data storage. TSI Link also supports compatible BlueSky and other TSI instruments; features differ by device and plan.

The standard package includes the monitor, universal USB power supply and cable, 24 VAC terminal connector, installed 32 GB MicroSD card and mounting kit. Select an indoor location representative of occupied conditions, provide continuous power and verify the 2.4 GHz Wi-Fi connection. TSI Link subscription term and enabled services are specified separately in the quotation.
Use continuous records to identify ventilation trends, particle events, cleaning-related VOC changes and pollutants entering occupied buildings. Model selection starts with the target gas. VOC is a broad sensor response and does not identify individual chemicals. Optical PM readings vary with aerosol properties. These fixed indoor monitors support building investigations; method-specific personal exposure measurements require the relevant sampling and analysis method.
| Gas | Model | Sensor Range |
|---|---|---|
| CO₂ | 8144-2 / 8144-4 / 8144-6 | 400–10,000 ppm |
| VOC | 8144-2 / 8144-4 / 8144-6 | 0–1,885 mg/m³ |
| CO | 8144-4 / 8144-6 | 0–1,000 ppm |
| Formaldehyde · H₂CO | 8144-4 | 0–1,000 ppb |
| NO₂ | 8144-6 | 0–20 ppm |
| SO₂ | 8144-6 | 0–10 ppm |
| O₃ | 8144-6 | 0–20 ppm |
Ranges are sensor measurement spans, not exposure limits. Accuracy, resolution, reference conditions and interferences are specified in the manufacturer datasheet and manual.
Sensor spans and permitted device operating conditions are different. Install the monitor indoors within 0–40 °C and 15–95% RH, non-condensing.
Use the exact device model and manufacturer part number when ordering. Multi-sensor cartridges are model-specific; CO₂ and formaldehyde sensors are separate components.
| Code | Description | Compatible Model | Enquiry |
|---|---|---|---|
| 814408 | VOC, temperature, relative humidity and pressure sensor cartridge | 8144-2 | Request a Quote ↗ |
| 814401 | CO, VOC, temperature, relative humidity and pressure sensor cartridge | 8144-4 | Request a Quote ↗ |
| 814402 | CO, O₃, NO₂, SO₂, VOC, temperature, relative humidity and pressure sensor cartridge | 8144-6 | Request a Quote ↗ |
| 814403 | Replacement PM sensor | 8144-2 / 8144-4 / 8144-6 | Request a Quote ↗ |
| 814404 | Replacement CO₂ sensor; separate from the multi-sensor cartridge | 8144-2 / 8144-4 / 8144-6 | Request a Quote ↗ |
| 814405 | Replacement formaldehyde sensor; 8144-4 only | 8144-4 | Request a Quote ↗ |
| 814406 | Replacement power supply kit | 8144-2 / 8144-4 / 8144-6 | Request a Quote ↗ |
| 814407 | Replacement membrane filters, pack of 3 | 8144-2 / 8144-4 / 8144-6 | Request a Quote ↗ |
Replacement parts are not an indication of stock availability or standard package contents. Follow manufacturer maintenance instructions; gas cartridge selection does not convert one model into another.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
No. The formaldehyde channel is provided on 8144-4. Model 8144-6 measures CO₂, VOC, CO, NO₂, SO₂ and O₃.
AirAssure is an indoor monitor. Its operating conditions are 0–40 °C and 15–95% RH, non-condensing. Review BlueSky for an outdoor monitoring project.
No. Cloud features, API access and subscription term depend on the selected service plan and supported device.
Technical basis: TSI datasheet 5002719 Rev G and operation/maintenance manual 6015658 Rev H.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.