NOVEL · Product and System Solutions

TSI IAQ-Calc™ Series

Occupational Safety and Environmental Measuring Instruments

TSI IAQ-Calc™ Series

Air Quality Monitoring Instrument and Environmental Analyser

The TSI IAQ-Calc™ Series is an outstanding choice for indoor air quality monitoring studies. Model 7515 is an economical option for carbon dioxide (CO2) measurement. Models 7525 and 7545 provide continuous measurement while featuring data logging capability. Model 7525 measures carbon dioxide (CO2), temperature, and humidity; alongside these, it performs dew point, wet bulb temperature, and outdoor air percentage calculations. Model 7545 measures carbon monoxide (CO) in addition to all these features.

Request a Quote from NOVEL ↗

From need to solution

Turn an air-quality complaint into measurement evidence

TSI IAQ-Calc™ Series: selection starts with the measurement or system output your team needs for its decision.

01

Customer need

Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.

02

Product output

Parameters measured by the fitted sensors or probes are reviewed with their measurement location and time.

03

Decision supported

Plan ventilation adjustments, follow-up investigation and monitoring points; a single parameter or spot reading does not describe every aspect of air quality or health risk.



Measurement and Standards Approach

Parameters to be measured in indoor air quality assessment should be selected based on intended use, building type, and source of complaint. Indoor building parameter standards such as EN 16798-1 should be evaluated alongside relevant national legislation and project criteria. Instrument data must not be interpreted on their own as a health diagnosis or regulatory compliance verdict.

Technical Specifications

Show Technical Details

Carbon dioxide (CO2)

Sensor Type Non-Dispersive Infrared (NDIR)
Range 0-5,000 ppm
Accuracy 3% of reading or ±50 ppm, whichever is greater (at 25°C)
Resolution 1ppm
Response Time 20 seconds

Temperature (Models 7525 and 7545 Only)

Sensor Type Thermistor
Range 0 - 60°C
Accuracy ±0.5°C
Resolution 0.1°C
Response Time 30 seconds (for 90% of final value, at 2 m/s air velocity)

Relative Humidity (Models 7525 and 7545 Only)

Sensor Type Thin-film Capacitive
Range 5% to 95% relative humidity
Accuracy ±3%
Resolution 0.1%
Response Time 20 seconds (for 63% of final value)

% Outside Air (Models 7525 and 7545 Only)

Range 0-100%
Resolution 0.1%

Carbon Monoxide (CO) (Model 7545 Only)

Sensor Type Electrochemical
Range 0-500 ppm
Accuracy 3% of reading or ±3 ppm, whichever is greater
Resolution 0.1ppm
Response Time <60 seconds (for 90% of final value)
Operating Temperature 5°C to 45°C

Data Logging (Models 7525 and 7545 Only)

Capacities Model 7525: Can log 30,300 data points. Model 7545: Can log 26,900 data points.
Logging Intervals 1 s - 5 s - 10 s - 20 s - 30 s
Time Constants 1 s - 1 hr
Dimensions and Weight 84 x 178 x 44 mm, Weight: 0.27 kg

Sampling Probe Dimensions

7515 Length: 70 mm, Diameter: 19 mm
7525 and 7545 Length: 178 mm, Diameter: 19 mm

Battery Specifications

7515 4xAA Alkaline Battery
7525 and 7545 4xAA Alkaline Battery or AC adapter

Product Specifications

  • Accurate measurement with non-dispersive infrared (NDIR) carbon dioxide (CO2) sensors

  • Logging multi-point measurements via sampling function

  • Ergonomic, custom-moulded hard carrying case

Product Documents

Accessories and Consumables

Accessories, consumables and replacement parts listed by the manufacturer. This is not a standard package-content list. Please specify the instrument model and part number; compatibility and supply are confirmed for your configuration.

CO2 and CO Calibration Kit 8938

8938

CO2 and CO Calibration Kit 8938

7525 / 7545; depending on sensor

Select for the installed CO/CO2 sensor channels. IAQ-Calc 7515/7525 do not measure CO.

Sectors

Alternative Products

You can examine product details and technical specifications by selecting an alternative suited to your requirements.

Frequently Asked Questions

What information is needed to select TSI IAQ-Calc™ Series?

Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.

Where can I find accessories and technical documents?

Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.

NOVEL technical support

For your application,
let us select the right solution together.

Request a Quote from NOVEL ↗

A draft opens in your email client with the subject header of the relevant product or category.