Customer need
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

The TSI IAQ-Calc™ Series is an outstanding choice for indoor air quality monitoring studies. Model 7515 is an economical option for carbon dioxide (CO2) measurement. Models 7525 and 7545 provide continuous measurement while featuring data logging capability. Model 7525 measures carbon dioxide (CO2), temperature, and humidity; alongside these, it performs dew point, wet bulb temperature, and outdoor air percentage calculations. Model 7545 measures carbon monoxide (CO) in addition to all these features.
From need to solution
TSI IAQ-Calc™ Series: selection starts with the measurement or system output your team needs for its decision.
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
Parameters measured by the fitted sensors or probes are reviewed with their measurement location and time.
Plan ventilation adjustments, follow-up investigation and monitoring points; a single parameter or spot reading does not describe every aspect of air quality or health risk.
Carbon dioxide (CO2) |
|
|---|---|
| Sensor Type | Non-Dispersive Infrared (NDIR) |
| Range | 0-5,000 ppm |
| Accuracy | 3% of reading or ±50 ppm, whichever is greater (at 25°C) |
| Resolution | 1ppm |
| Response Time | 20 seconds |
Temperature (Models 7525 and 7545 Only) |
|
|---|---|
| Sensor Type | Thermistor |
| Range | 0 - 60°C |
| Accuracy | ±0.5°C |
| Resolution | 0.1°C |
| Response Time | 30 seconds (for 90% of final value, at 2 m/s air velocity) |
Relative Humidity (Models 7525 and 7545 Only) |
|
|---|---|
| Sensor Type | Thin-film Capacitive |
| Range | 5% to 95% relative humidity |
| Accuracy | ±3% |
| Resolution | 0.1% |
| Response Time | 20 seconds (for 63% of final value) |
% Outside Air (Models 7525 and 7545 Only) |
|
|---|---|
| Range | 0-100% |
| Resolution | 0.1% |
Carbon Monoxide (CO) (Model 7545 Only) |
|
|---|---|
| Sensor Type | Electrochemical |
| Range | 0-500 ppm |
| Accuracy | 3% of reading or ±3 ppm, whichever is greater |
| Resolution | 0.1ppm |
| Response Time | <60 seconds (for 90% of final value) |
| Operating Temperature | 5°C to 45°C |
Data Logging (Models 7525 and 7545 Only) |
|
|---|---|
| Capacities | Model 7525: Can log 30,300 data points. Model 7545: Can log 26,900 data points. |
| Logging Intervals | 1 s - 5 s - 10 s - 20 s - 30 s |
| Time Constants | 1 s - 1 hr |
| Dimensions and Weight | 84 x 178 x 44 mm, Weight: 0.27 kg |
Sampling Probe Dimensions |
|
|---|---|
| 7515 | Length: 70 mm, Diameter: 19 mm |
| 7525 and 7545 | Length: 178 mm, Diameter: 19 mm |
Battery Specifications |
|
|---|---|
| 7515 | 4xAA Alkaline Battery |
| 7525 and 7545 | 4xAA Alkaline Battery or AC adapter |
Accurate measurement with non-dispersive infrared (NDIR) carbon dioxide (CO2) sensors
Logging multi-point measurements via sampling function
Ergonomic, custom-moulded hard carrying case
Accessories, consumables and replacement parts listed by the manufacturer. This is not a standard package-content list. Please specify the instrument model and part number; compatibility and supply are confirmed for your configuration.

801679
7515 / 7525 / 7545
Collar for applying calibration gas to the instrument.

8938
7525 / 7545; depending on sensor
Select for the installed CO/CO2 sensor channels. IAQ-Calc 7515/7525 do not measure CO.

8936
7525 / 7545; depending on sensor
Select calibration gas in accordance with the instrument manual.

8937
7525 / 7545; depending on sensor
Select calibration gas in accordance with the instrument manual.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.