NOVEL · Product and System Solutions

TSI OmniWear Noise™ Personal Noise Dosemeter

Occupational Safety and Environmental Measuring Instruments

TSI OmniWear Noise personal noise dosimeter

Collar-Mounted Personal Noise Exposure Meter with Bluetooth® Connectivity

TSI OmniWear Noise™ is a compact personal noise dosemeter developed to monitor and log the noise workers are exposed to throughout the working day. Thanks to Bluetooth® connectivity, instrument setup, live measurement tracking, remote start/stop, data transfer, and PDF report generation can be carried out via the TSI OmniWear Noise™ mobile app.

Request a Quote from NOVEL ↗



Product Specifications
  • Complies with the IEC 61252 noise dosemeter standard; supports common measurement protocols such as ISO 9612, OSHA, ACGIH, and MSHA.

  • Wireless connection via Bluetooth® to a phone or tablet; remote monitoring and control of multiple dosemeters.

  • Supports A, C, and Z frequency weightings along with Fast and Slow time weightings.

  • 1-second time-history profile, motion detection, pause function, and simultaneous noise dose parameters.

  • Robust IP65-rated enclosure, MEMS microphone, and approximately 16 hours of run time.

  • Modular wireless charging system; up to 10 charging modules can be linked together using a single power supply.

  • Measurement results can be viewed in the mobile app; automated PDF reports can be shared via phone or tablet.

  • Product Documents
  • TSI OmniWear Noise™ – Product Overview

  • TSI OmniWear Noise™ – Use and Application

  • You can visit the original website   
    Technical Specifications

    Product Videos

    TSI OmniWear Noise product overview
    TSI OmniWear Noise product overview
    Watch Video ↗
    TSI OmniWear Noise application video
    TSI OmniWear Noise application video
    Watch Video ↗

    Technical Specifications

    Technical Table
    Application Type Personal Noise Exposure Meter (Dosemeter)
    Battery Type, Operating Life Li-ion 350 mAh; typical 16 hours run time, 100% charge in approx. 6 hours
    Data Logging Maximum 64 measurement runs; 1-second time-history profile and data transfer / PDF reporting via mobile app
    Instrument Kit Contents OmniWear Noise unit, charger module, windscreen, protective accessories depending on configuration; 5/10/20-unit kit options
    Weight 36 g
    Measurement Parameters LXY, LXYmax, LXeq, LXpeak, LAvg, LXIeq, LTM3, LTM5, LAE; LEX,8h, TWA, % Dose, projected dose, Pa²h, Pa²s, motion %, LASmax
    Standards ANSI S1.25:1991 R2024; BS EN 61252:1997+A2:2017
    Response Range Fast and Slow
    Weighted Measurement A, C, and Z; exchange rate Q=3 or Q=5 dB
    Linear Operating Range70–140.3 dB(A) RMS
    Peak Measurement Range90.0–143.3 dB(C or Z)
    Protection ClassIP65
    Dimensions56 × 32 × 40 mm
    Bluetooth / MobileLive monitoring, start/stop, and reporting via mobile app; control/monitoring of up to 20 instruments according to manufacturer announcement

    Measurement and Standards Approach

    OmniWear Noise™ is a noise dosemeter used to monitor workers' personal noise exposure on a shift and task basis. Measurement criteria and dosimetry parameters must be configured according to the occupational hygiene methodology to be applied, corporate procedures, and prevailing regulations; the acoustic verification/calibration protocol before and after measurement must also be maintained.

    In the manufacturer's current technical documentation, the instrument is specified under ANSI S1.25:1991 R2024 and BS EN 61252:1997+A2:2017. ISO 9612 is not an instrument certification, but a measurement and calculation standard for employee noise exposure; therefore, the instrument standard, field calibration, and measurement methodology must be evaluated together.

    Sectors

    Alternative Products

    You can examine product details and technical specifications by selecting an alternative suited to your requirements.

    Frequently Asked Questions About TSI OmniWear Noise™

    Which noise dosemeter standards does OmniWear Noise meet?
    According to the manufacturer's current technical documentation, it meets the requirements of ANSI S1.25:1991 R2024 and BS EN 61252:1997+A2:2017.
    Can OmniWear Noise be used for ISO 9612 measurements?
    OmniWear Noise provides an ISO 9612 preset for personal noise exposure measurement. ISO 9612 is not an instrument certification; it is an application standard that defines the measurement strategy, measurement duration, field calibration, and exposure calculation methodology.
    What are the run time and measurement range of OmniWear Noise?
    Typical run time is 16 hours. The linear operating range is specified as 70–140.3 dB(A) RMS, and the peak measurement range as 90–143.3 dB(C or Z).
    How many instruments can OmniWear Noise monitor via the mobile app?
    According to TSI's current product announcement, the mobile app provides control and monitoring support for up to 20 instruments via Bluetooth.

    Notice: The technical information, product specifications and images on this page are based on manufacturer publications. The manufacturer may change specifications without notice. For current specifications or assistance in selecting a suitable product for your application, please contact NOVEL at info@novel.com.tr .

    NOVEL technical support

    For your application,
    let us select the right solution together.

    Request a Quote from NOVEL ↗

    A draft opens in your email client with the subject header of the relevant product or category.