NOVEL · Product and System Solutions

TSI OmniWear Noise™ Personal Noise Dosemeter

Occupational Safety and Environmental Measuring Instruments

TSI OmniWear Noise personal noise dosimeter

Collar-Mounted Personal Noise Exposure Meter with Bluetooth® Connectivity

TSI OmniWear Noise™ is a compact personal noise dosemeter developed to monitor and log the noise workers are exposed to throughout the working day. Thanks to Bluetooth® connectivity, instrument setup, live measurement tracking, remote start/stop, data transfer, and PDF report generation can be carried out via the TSI OmniWear Noise™ mobile app.

Request a Quote from NOVEL ↗

From need to solution

Relate noise to the task and its duration

TSI OmniWear Noise™ Personal Noise Dosemeter: selection starts with the measurement or system output your team needs for its decision.

01

Customer need

Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.

02

Product output

Sound-level, exposure or analysis indicators supported by the chosen model are recorded with the field conditions.

03

Decision supported

Prioritise sources, further measurements and controls, distinguishing the role of a dosimeter from a sound-level meter and checking acoustic calibration requirements.



Measurement and Standards Approach

OmniWear Noise™ is a noise dosemeter used to monitor workers' personal noise exposure on a shift and task basis. Measurement criteria and dosimetry parameters must be configured according to the occupational hygiene methodology to be applied, corporate procedures, and prevailing regulations; the acoustic verification/calibration protocol before and after measurement must also be maintained.

In the manufacturer's current technical documentation, the instrument is specified under ANSI S1.25:1991 R2024 and BS EN 61252:1997+A2:2017. ISO 9612 is not an instrument certification, but a measurement and calculation standard for employee noise exposure; therefore, the instrument standard, field calibration, and measurement methodology must be evaluated together.

Product Videos

TSI OmniWear Noise product overview
TSI OmniWear Noise product overview
Watch Video ↗
TSI OmniWear Noise application video
TSI OmniWear Noise application video
Watch Video ↗

Technical Specifications

Technical Specifications

Technical Table
Application Type Personal Noise Exposure Meter (Dosemeter)
Battery Type, Operating Life Li-ion 350 mAh; typical 16 hours run time, 100% charge in approx. 6 hours
Data Logging Maximum 64 measurement runs; 1-second time-history profile and data transfer / PDF reporting via mobile app
Instrument Kit Contents OmniWear Noise unit, charger module, windscreen, protective accessories depending on configuration; 5/10/20-unit kit options
Weight 36 g
Measurement Parameters LXY, LXYmax, LXeq, LXpeak, LAvg, LXIeq, LTM3, LTM5, LAE; LEX,8h, TWA, % Dose, projected dose, Pa²h, Pa²s, motion %, LASmax
Standards ANSI S1.25:1991 R2024; BS EN 61252:1997+A2:2017
Response Range Fast and Slow
Weighted Measurement A, C, and Z; exchange rate Q=3 or Q=5 dB
Linear Operating Range70–140.3 dB(A) RMS
Peak Measurement Range90.0–143.3 dB(C or Z)
Protection ClassIP65
Dimensions56 × 32 × 40 mm
Bluetooth / MobileLive monitoring, start/stop, and reporting via mobile app; control/monitoring of up to 20 instruments according to manufacturer announcement

Product Specifications

  • Complies with the IEC 61252 noise dosemeter standard; supports common measurement protocols such as ISO 9612, OSHA, ACGIH, and MSHA.

  • Wireless connection via Bluetooth® to a phone or tablet; remote monitoring and control of multiple dosemeters.

  • Supports A, C, and Z frequency weightings along with Fast and Slow time weightings.

  • 1-second time-history profile, motion detection, pause function, and simultaneous noise dose parameters.

  • Robust IP65-rated enclosure, MEMS microphone, and approximately 16 hours of run time.

  • Modular wireless charging system; up to 10 charging modules can be linked together using a single power supply.

  • Measurement results can be viewed in the mobile app; automated PDF reports can be shared via phone or tablet.

Product Documents

Acoustic Calibration and Matching Adapters

Use the manufacturer-specified calibrator and matching microphone adapter for pre/post field checks. For Edge 7/8 use 114 dB at 1 kHz. Field checks do not replace periodic instrument/calibrator laboratory calibration.

CEL-120/2 Acoustic Calibrator

CEL-120/2

CEL-120/2 Acoustic Calibrator

114 dB / 1 kHz field check with the ½-inch microphone. Follow the dosimeter fitting procedure; check whether the calibrator is included in your kit.

Sectors

Alternative Products

You can examine product details and technical specifications by selecting an alternative suited to your requirements.

Frequently Asked Questions About TSI OmniWear Noise™

Which noise dosemeter standards does OmniWear Noise meet?
According to the manufacturer's current technical documentation, it meets the requirements of ANSI S1.25:1991 R2024 and BS EN 61252:1997+A2:2017.
Can OmniWear Noise be used for ISO 9612 measurements?
OmniWear Noise provides an ISO 9612 preset for personal noise exposure measurement. ISO 9612 is not an instrument certification; it is an application standard that defines the measurement strategy, measurement duration, field calibration, and exposure calculation methodology.
What are the run time and measurement range of OmniWear Noise?
Typical run time is 16 hours. The linear operating range is specified as 70–140.3 dB(A) RMS, and the peak measurement range as 90–143.3 dB(C or Z).
How many instruments can OmniWear Noise monitor via the mobile app?
According to TSI's current product announcement, the mobile app provides control and monitoring support for up to 20 instruments via Bluetooth.
You can visit the original website   

NOVEL technical support

For your application,
let us select the right solution together.

Request a Quote from NOVEL ↗

A draft opens in your email client with the subject header of the relevant product or category.