Occupational Safety and Environmental Measuring Instruments

TSI Quest Edge 4 Plus personal noise dosimeter

Personal Noise Exposure Monitoring with Quest Edge 4+

EDGE is a cable-free, lightweight, user-friendly personal noise dosimeter designed to measure personal noise exposure with high accuracy under varying environmental conditions. These advanced instruments compute all required dosimetric metrics throughout the run duration (Dose, SPL, Peak, Upper Limit (UL), TWA, Identity Field, SEL (Lep), Run Time, Threshold, Exposure, Lavg/Leq, Max, L(C-A), Projected Dose, Min).

Request a Quote from NOVEL ↗

From need to solution

Relate noise to the task and its duration

TSI Edge 4 Plus Noise Dosimeter: selection starts with the measurement or system output your team needs for its decision.

01

Customer need

Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.

02

Product output

Sound-level, exposure or analysis indicators supported by the chosen model are recorded with the field conditions.

03

Decision supported

Prioritise sources, further measurements and controls, distinguishing the role of a dosimeter from a sound-level meter and checking acoustic calibration requirements.



Product Features

Personal noise exposure

Worn at the shoulder/collar to record a worker’s exposure through the shift.

Two independent dosimeters

Evaluate two measurement approaches using different criteria and 3/4/5 dB exchange rates.

Measurement range

RMS 70–140 dB; peak 110–143 dB. Set acquisition and reporting for the assessment method.

Lightweight, readable design

85 g body, OLED display and programmable LED dose indication.

Battery and data handling

Manufacturer runtime: 60+ hours with display timeout enabled; 20 hours without it. EdgeDock supports charging/data.

Optional Bluetooth

Edge dB mobile app with suitable hardware; AC-300 calibrator and single/five-bay EdgeDock options.

Configuration, communications and accessory compatibility are verified for the ordered model and service. Standard and Ex versions have different approval scopes.

Manufacturer Product Information ↗

Measurement and Standards Approach

The Edge 4 Plus is a dosimetry platform used for monitoring personal noise exposure on the worker across a shift. Measurement criteria and reporting parameters must be configured according to the occupational hygiene methodology to be applied, corporate procedures, and applicable regulations; the pre- and post-measurement acoustic verification/calibration routine must also be maintained.

Standard compliance: In TSI's Edge 4 Plus technical documentation, it is stated that the instrument meets the requirements of ANSI S1.25 Personal Noise Dosimeters and IEC 61252 Personal Sound Exposure Meters. The Edge 4 Plus features two independent dosimeters; threshold can be configured as 70–90 dB or off, and exchange rate can be set to 3, 4, or 5 dB for each dosimeter. ISO 9612 is not an instrument certification, but a measurement strategy and calculation standard for determining occupational noise exposure of workers. Therefore, during field studies, an appropriate measurement strategy and pre-/post-measurement acoustic calibration procedure must be implemented alongside the instrument standard.

Product Videos

  • How do we calibrate the EDGE instrument?

  • TSI Quest Edge noise dosimeter calibration
    Watch Video ↗
  • Configuring and operating the EDGE instrument

  • Configuring and operating the TSI Quest Edge noise dosimeter
    Watch Video ↗
  • Starting measurements with the EDGE instrument

  • Starting personal noise measurements with the TSI Quest Edge
    Watch Video ↗
  • Importing data from the EDGE instrument into the DMS program and reviewing measurement data

  • Transferring TSI Quest Edge data to the DMS software
    Watch Video ↗

    Technical Specifications

    Show Technical Details
    Application Type Personal Exposure Meter (Dosimeter)
    Battery Type, Operating Life Rechargeable Lithium Polymer, 40 Hours
    Data Logging 180 Hours, detailed data analysis, data storage, and reporting can be carried out with DMS software
    Instrument Kit Contents Docking Station, USB Cable (for Data Logging), Charger, Shoulder Mounting Clips, Windshield, Calibration Adaptor, DMS Software, Carrying Case
    Weight 85 g
    Measurement Parameters Dose, SPL, Peak, Upper Limit (UL), TWA, Identity Field, SEL (Lep), Run Time, Threshold, Exposure, Lavg/Leq, Max, L(C-A), Projected Dose, Min
    Standards IEC 61252, CE, ANSI S1.25, CE
    Response Range Fast or Slow
    Weighted Measurement A, C, Z
    RMS Measurement Range70–140 dB
    Threshold70–90 dB selectable or off
    Exchange Rate3 dB, 4 dB or 5 dB for each independent dosimeter
    Criterion Level70–90 dB in 1 dB steps
    Independent Dosimeter2 independent dosimeters; simultaneous evaluation against different criteria in the same field study
    BluetoothWireless monitoring and control via the Edge dB mobile application; up to approximately 25 m line-of-sight range in interference-free environments according to manufacturer specifications

    Acoustic Calibration and Matching Adapters

    Use the manufacturer-specified calibrator and matching microphone adapter for pre/post field checks. For Edge 7/8 use 114 dB at 1 kHz. Field checks do not replace periodic instrument/calibrator laboratory calibration.

    TSI QUEST AC-300 Class 1 sound calibrator

    AC-300

    AcoustiCal AC-300 Class 1 Calibrator

    Pre/post measurement acoustic checks with a supported microphone and matching adapter. Select level, microphone type and corrections according to the instrument manual.

    Sectors

    Alternative Products

    You can examine product details and technical specifications by selecting an alternative suited to your requirements.

    Frequently Asked Questions About TSI Quest Edge 4 Plus

    Which noise dosimeter standards does the Edge 4 Plus meet?
    TSI technical documents specify ANSI S1.25 Personal Noise Dosimeters and IEC 61252 Personal Sound Exposure Meters standards for the Edge 4 Plus.
    Can the Edge 4 Plus measure simultaneously with different noise criteria?
    Yes. Edge 4 Plus has two independent dosimeters. By configuring parameters such as threshold, exchange rate, and criterion level according to different criteria, the same run can be monitored using different evaluation approaches.
    Can the Edge 4 Plus be used in ISO 9612 studies?
    The Edge 4 Plus is a dosimeter intended for measuring personal noise exposure on workers on a shift- and task-based basis. ISO 9612 is not an instrument certification, but a measurement strategy and calculation standard; in practice, the relevant measurement plan and acoustic calibration procedure must be applied together.
    How are Edge 4 Plus data reported?
    Edge 4 Plus measurement data can be transferred to TSI Quest Detection Management Software (DMS) via EdgeDock; DMS provides data storage, graphing, analysis, and reporting functions.