Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.
NOVEL · Product and System Solutions
TSI Quest Edge 8 ATEX / IECEx Personal Noise Dosimeter
Occupational Safety and Environmental Measuring Instruments

The TSI Quest Edge 8 is an intrinsically safe personal noise dosimeter developed to safely monitor the personal noise exposure of workers in industrial environments with explosive atmosphere risks. In addition to ATEX and IECEx certification, it provides four independently configurable dosimeters, BLE5 Bluetooth®, 1/1 octave band analysis, voice notes, event audio recording, and the TSI Detection Management Software (DMS) workflow. It supports detailed assessment of personal noise exposure in mining, oil and gas, refineries, chemical processing, and other hazardous area applications.
From need to solution
TSI Quest Edge 8 Noise Dosimeter: selection starts with the measurement or system output your team needs for its decision.
Noise control requires level and duration information appropriate to the assessment, beyond the perception of loudness alone.
Sound-level, exposure or analysis indicators supported by the chosen model are recorded with the field conditions.
Prioritise sources, further measurements and controls, distinguishing the role of a dosimeter from a sound-level meter and checking acoustic calibration requirements.
Official source: İSGÜM – Laboratory Authorization and TS EN ISO 9612 occupational hygiene noise resources ↗

Technical Specifications
| Model | EG8 / EG8-BT / EG8M-BT |
|---|---|
| Connectivity | USB via EdgeConnect docking; BLE 5 / Edge dB application on Bluetooth models |
| Virtual Dosimeter | 4 independently configurable |
| Frequency Analysis | 1/1 octave band analysis |
| Microphone | 1/2-inch MEMS, field replaceable microphone |
| Data Management | Edge dB mobile application and TSI DMS |
| Measurement Range | 70–140 dB RMS; 110–143 dB Peak |
| Potentially Explosive Atmosphere | ATEX / IECEx intrinsically safe |
| Ingress Protection | IP65 |
| RMS Measurement Range | 70–140 dB |
| Peak Measurement Range | 110–143 dB |
| RMS Frequency Weighting | A or C |
| Peak Weighting | C or Z |
| Time Weighting | Fast or Slow |
| Independent Dosimeter | 4 independent dosimeters |
| Threshold | 70–90 dB in 1 dB steps or off |
| Exchange Rate | Independently 3 dB, 4 dB, or 5 dB for each dosimeter |
| Criterion Level | 70–90 dB in 1 dB steps |
| Standards | ANSI S1.25-1991 (R2017); IEC 61252:1993 + AMD1:2000 + AMD2:2017 |
| ATEX / IECEx | ATEX Directive 2014/34/EU; Ex ia IIC T4 Ga; Ex ia I Ma; IECEx UL24.0016; ATEX UL 24ATEX3178 |
| Battery | Rechargeable Li-Polymer; nominal 30 hours with display off |
| Memory | Logging capacity up to 100 days with 1-minute logging |
| Protection Class | IP65 |
| Dimensions / Weight | 123.4 × 59.2 × 32 mm / 4.16 oz (approximately 118 g) |
| Advanced Functions | Pause Study, Voice Notes, event audio recording, Ceiling Count, 1/1 octave analysis, and DMS reporting |
| İSGÜM / TS EN ISO 9612 Approach | In İSGÜM's laboratory authorization resources, the TS EN ISO 9612 task-based, job-based, and full-day measurement approach is used for personal noise exposure. Job analysis, appropriate measurement strategy, measurement, uncertainty evaluation, and reporting must be conducted together. |
|---|---|
| Personal Exposure Measurement | For comparison with occupational exposure limit values, personal noise exposure must be monitored from a point close to the worker's hearing zone. The Edge 8 supports shift- and task-based measurements with its shoulder-worn personal dosimeter design. |
| Four Independent Dosimeters | Edge 8 can run four independent dosimeter profiles simultaneously; threshold, exchange rate, and criterion level parameters can be independently configured according to corporate procedures or different assessment criteria. |
| ATEX / IECEx Hazardous Area | TSI's current technical datasheet for the Edge 8 specifies ATEX Directive 2014/34/EU and IECEx certifications. The instrument supports Ex ia IIC T4 Ga and Ex ia I Ma classifications. Prior to use, the field zone classification, gas group, temperature class, and current certification scope must be independently verified. |
| Measurement Data for ISO 9612 | RMS, dose, TWA, LAVG/LEQ, peak, maximum/minimum values, and time-history records can be used in personal exposure evaluation. 1/1 octave analysis provides additional data for evaluating the frequency composition of noise and noise control measures. |
| Calibration and Field Check | Pre- and post-measurement acoustic verification must be conducted using an appropriate calibrator and a valid field procedure. Manufacturer safety instructions and site procedures must also be observed for accessories and operations to be used in hazardous areas. |
| Raw Data and Recording | Edge 8 provides a logging capacity of up to 100 days with a 1-minute logging interval. Measurement data can be stored, analyzed, and reported via EdgeConnect and DMS. |
| Application in Turkey | Under the TS EN ISO 9612 method, instrument standard compliance alone is not sufficient. Together with calibration, microphone location, task durations, uncertainty calculation, and laboratory procedures; suitability with the facility's hazardous area classification must also be verified in ATEX/IECEx areas. |
Supports management of field studies via BLE5 Bluetooth and the Edge dB mobile application.
Helps evaluate different exposure criteria in the same study using four independently configurable virtual dosimeters.
Offers advanced analysis functions such as 1/1 octave band data logging, voice notes, and event audio recording.
Use the manufacturer-specified calibrator and matching microphone adapter for pre/post field checks. For Edge 7/8 use 114 dB at 1 kHz. Field checks do not replace periodic instrument/calibrator laboratory calibration.

AC-300
Pre/post measurement acoustic checks with a supported microphone and matching adapter. Select level, microphone type and corrections according to the instrument manual.
Modele özel halka
Use 114 dB / 1 kHz with the manufacturer ring matching the dosimeter. Match the actual microphone and ring when requesting a quotation.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.