Customer need
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
NOVEL · Product and System Solutions
Occupational Safety and Environmental Measuring Instruments

On-screen data and step-by-step instructions guide the user through operation, instrument setup, and field calibration. The Q-Trak IAQ Monitor 7575 also features a probe holder and keypad lock to prevent unauthorised use and tampering. It has an ergonomic, custom-moulded hard carrying case. The Q-Trak IAQ Monitor 7575 is designed to work with a wide variety of plug-in probes that expand measurement capability.
From need to solution
TSI Q-TRAK: selection starts with the measurement or system output your team needs for its decision.
Indoor investigations need information about changes associated with ventilation, occupancy and potential sources.
Parameters measured by the fitted sensors or probes are reviewed with their measurement location and time.
Plan ventilation adjustments, follow-up investigation and monitoring points; a single parameter or spot reading does not describe every aspect of air quality or health risk.
Carbon dioxide (CO2) (980 and 982 IAQ Probe Models) |
|
|---|---|
| Sensor Type | Non-Dispersive Infrared (NDIR) |
| Range | 0-5,000 ppm |
| Accuracy | 3% of reading or ±50 ppm, whichever is greater (at 25°C) |
| Resolution | 1ppm |
| Response Time | 20 seconds |
Temperature (980 and 982 IAQ Probe Models) |
|
|---|---|
| Sensor Type | Thermistor |
| Range | 0 - 60°C |
| Accuracy | ±1°C |
| Resolution | 0.1°C |
| Response Time | 30 seconds (for 90% of final value, at 2 m/s air velocity) |
Relative Humidity (980 and 982 IAQ Probe Models) |
|
|---|---|
| Sensor Type | Thin-film Capacitive |
| Range | 5% to 95% relative humidity |
| Accuracy | ±3% |
| Resolution | 0.1% |
| Response Time | 20 seconds (for 63% of final value) |
Percentage of Outdoor Air |
|
|---|---|
| Range | 0-100% |
| Resolution | 0.1% |
Carbon monoxide (CO) (982 IAQ Probe Model) |
|
|---|---|
| Sensor Type | Electrochemical |
| Range | 0-500 ppm |
| Accuracy | 3% of reading or ±3 ppm, whichever is greater |
| Resolution | 0.1ppm |
| Response Time | <60 seconds (for 90% of reading) |
Barometric Pressure |
|
|---|---|
| Range | 20.36 - 36.648 in. Hg (517.15 - 930.87 mm Hg) |
| Accuracy | ±2% |
| Operating Temperature | 5°C to 45°C |
| Storage Temperature | Between -20°C and 60°C |
Data Logging |
|
|---|---|
| Capacities | Has a storage capacity of 56,036 data points. Capable of logging data for 39 days with a 1-minute logging interval. |
| Logging Intervals | 1s-5s-10s-20s-30s (user-selectable) |
| Data Logging Intervals | 1s-1h (user-selectable) |
| Dimensions and Weight | 9.7 x 21.1 x 5.3 cm, Weight: 0.36kg |
| Battery Specifications | 4xAA Alkaline Batteries or AC adapter |
| Standard Accessories | Hard carrying case, 4 x AA Alkaline batteries, USB cable, universal charger, user manual, calibration certificate, TrakPro Software |
Continuous measurement of carbon dioxide, carbon monoxide, temperature, and relative humidity
Calculates dew point, wet bulb, and outdoor air percentages.
Convenient Graphical Display - Information on up to 5 measurements - On-screen informative messages and instructions
Versatile instrument including VOC and air velocity measurement via plug-in probes
Data logging, data analysis, and reporting with TrakPro™ Data Analysis Software
Data storage capacity of up to 39 days at 1-minute intervals
Accessories, consumables and replacement parts listed by the manufacturer. This is not a standard package-content list. Please specify the instrument model and part number; compatibility and supply are confirmed for your configuration.

980
Q-Trak 7575; matching probe/configuration
Interchangeable IAQ probe for Q-Trak 7575.

982
Q-Trak 7575; matching probe/configuration
IAQ probe including a CO channel.

985
Q-Trak 7575; matching probe/configuration
Probe for ppm VOC investigations.

986
Q-Trak 7575; matching probe/configuration
Probe for low-concentration ppb VOC investigations.

987
Q-Trak 7575; matching probe/configuration
Combines ppm VOC with IAQ parameters.

8938
Q-Trak 7575; matching probe/configuration
Select for the installed CO/CO2 sensor channels. IAQ-Calc 7515/7525 do not measure CO.
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.