By Colour Change Method Short-Term Gas Measurement System and AP-20 Pump
Search by chemical or tube code, compare measurement ranges and open the relevant product documents.
Shelf life is a nominal duration, not the remaining life of the supplied lot. The expiry date and storage conditions on the box take precedence. Storage temperature is separate from measurement temperature. If no refrigeration note is shown here, check the current instructions; absence of a note does not mean refrigeration is unnecessary.
Komyo Kitagawa Short-Term Gas Measurement Detector Tube List
No Kitagawa detector tubes matching your search were found.
106SC Carbon Monoxide (CO) Kitagawa Detector Tube - Carbon Monoxide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 50 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
126SF Carbon dioxide (CO2) Kitagawa Detector Tube - Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 4000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
137U Hydrogen (H2) Kitagawa Detector Tube - Hydrogen Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 0,8 %Shelf Life
3 YearsQuantity per Box
5 pcs/box
159SC Oxygen (O2) Kitagawa Detector Tube - Oxygen Kitagawa Detector Tube
Typical Applications
Measurement Range
1,5 - 24 %Shelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
173SB Hydrogen Chloride (HCl) Kitagawa Detector Tube - Hydrogen Chloride Kitagawa Detector Tube
Typical Applications
Measurement Range
0.4 - 40.0 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
175U Nitrogen Oxide (NOx) Kitagawa Detector Tube - Nitrogen Oxides Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 30 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
177U Water Vapour ( H2O) Kitagawa Detector Tube - Water Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 2.0 mg/LShelf Life
3 YearsQuantity per Box
10 pcs/box
182U Ozone (O3) Kitagawa Detector Tube - Ozone Kitagawa Detector Tube
Typical Applications
Measurement Range
0.025 - 3.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
216S Acetic Acid (CH3COOH) Kitagawa Detector Tube - Acetic Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 125 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Acetic Anhydride (C4H6O3) Kitagawa Detector Tube - Acetic Anhydride Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 15 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Acrylic Acid (C3H4O2) Kitagawa Detector Tube - Acrylic Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Butyric Acid (C4H8O2) Kitagawa Detector Tube - Butyric Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 60 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Formic Acid (CH2O2) Kitagawa Detector Tube - Formic Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Isobutyric Acid (C4H8O2) Kitagawa Detector Tube - Isobutyric Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Isovaleric Acid (C5H10O2) Kitagawa Detector Tube - Isovaleric Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Maleic Acid (C4H2O3) Kitagawa Detector Tube - Maleic Anhydride Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 10 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Methacrylic Acid (C4H6O2) Kitagawa Detector Tube - Methacrylic Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S N-Valeric Acid (C5H10O2) Kitagawa Detector Tube - N-Valeric Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 70 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
216S Propionic Acid (C3H6O2) Kitagawa Detector Tube - Propionic Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
244U Sulphuric Acid (H2SO4) Kitagawa Detector Tube - Sulphuric Acid Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 5 mg/m3Shelf Life
2 YearsQuantity per Box
10 pcs/box
602SP Oil Mist Kitagawa Detector Tube - Oil Mist Kitagawa Detector Tube
Typical Applications
Measurement Range
0.3 - 5 mg/m3Shelf Life
2 YearsQuantity per Box
10 pcs/box116 Chlorine dioxide (ClO₂) Kitagawa Detector Tube - Chlorine Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
101S Acetylene (C2H2) Kitagawa Detector Tube - Acetylene Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
102SD Acetone (C3H6O) Kitagawa Detector Tube - Acetone Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 5000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
103SC Sulphur Dioxide (SO2) Kitagawa Detector Tube - Sulphur Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 300 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
103SD Sulphur Dioxide (SO2) Kitagawa Detector Tube - Sulphur Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 60 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
103SE Sulphur Dioxide (SO2) Kitagawa Detector Tube - Sulphur Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.25 - 10 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
103SG Sulphur Dioxide (SO2) (in Carbon Dioxide) Kitagawa Detector Tube - Sulphur Dioxide in Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 25 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
104SA Ethyl Alcohol (Ethanol) (C2H5OH) Kitagawa Detector Tube - Ethyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 5,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
104SB Ethyl Alcohol (Ethanol) (C2H5OH) Kitagawa Detector Tube - Ethyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 300 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
105SB Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 900 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SC Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 260 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Butyl Amine (C4H11N) Kitagawa Detector Tube - Butyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Cyclohexylamine (C6H13N) Kitagawa Detector Tube - Cyclohexylamine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Dibutyl Amine (C8H19N) Kitagawa Detector Tube - Dibutyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Diisopropylamine (C6H15N) Kitagawa Detector Tube - Diisopropylamine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 16 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Dipropylamine (C6H15N) Kitagawa Detector Tube - Dipropylamine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 14 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Morpholine (C4H9NO) Kitagawa Detector Tube - Morpholine Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 22 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD N-Methyl Aniline (C7H9N) Kitagawa Detector Tube - N-Methyl Aniline Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 6 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD N, N-Dimethyl Aniline (C8H11N) Kitagawa Detector Tube - N, N-Dimethylaniline Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 9 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box105SD o-Toluidine (C₇H₉N) Kitagawa Detector Tube - o-Toluidine Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 22 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box105SD p-Toluidine (C₇H₉N) Kitagawa Detector Tube - p-Toluidine Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Pentyl Amine (C5H13N) Kitagawa Detector Tube - Pentyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 22 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Propyl Amine (C3H9N) Kitagawa Detector Tube - Propyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SD Pyridine (C5H5N) Kitagawa Detector Tube - Pyridine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SE Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 200 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
105SE Trimethylamine (C3H9N) Kitagawa Detector Tube - Trimethylamine Kitagawa Detector Tube
Typical Applications
Measurement Range
05 - 100 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
106C Carbon Monoxide (CO) (in presence of Ethylene and Nitrogen Oxides) Kitagawa Detector Tube - Carbon Monoxide in presence of Ethylene and Nitrogen OxidesKitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
106S Carbon Monoxide (CO) Kitagawa Detector Tube - Carbon Monoxide Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 250 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
106SA Carbon Monoxide (CO) Kitagawa Detector Tube - Carbon Monoxide Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 2000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
107U Ethyl Ether ((C2H5)2O) Kitagawa Detector Tube - Ethyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 400 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
108B Ethylene (C2H4) Kitagawa Detector Tube - Ethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 100 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
108SA Ethylene (C2H4) Kitagawa Detector Tube - Ethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
108SC Ethylene (C2H4) Kitagawa Detector Tube - Ethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 200 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
109SA Chlorine (Cl) Kitagawa Detector Tube - Chlorine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 40 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
109SB Chlorine (Cl) Kitagawa Detector Tube - Chlorine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 10.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
109U Chlorine (Cl) Kitagawa Detector Tube - Chlorine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 2 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111SA Ethyl Acetate (C4H8O2) Kitagawa Detector Tube - Ethyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 5,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
111SA Methyl Acetate (C3H6O2) Kitagawa Detector Tube - Methyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 3,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
111U Ethyl Acetate (C4H8O2) Kitagawa Detector Tube - Ethyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Trimethyl Benzene (C9H12) Kitagawa Detector Tube - 1,2,4-Trımethyl Benzene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 250 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Butyl Ether (C8H18O) Kitagawa Detector Tube - Butyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Butyl Methacrylate (C8H14O2) Kitagawa Detector Tube - Butyl Methacrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Cumene (C9H12) Kitagawa Detector Tube - Cumene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 140 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Cyclohexene (C6H10) Kitagawa Detector Tube - Cyclohexene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 300 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Decahydronaphthalene (C10H18) Kitagawa Detector Tube - Decahydronaphthalene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Diethylbenzene Kitagawa Detector Tube - Diethylbenzene Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 180 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Ethyl Methacrylate (C6H10O2) Kitagawa Detector Tube - Ethyl Methacrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Isopropyl Acetate (C5H10O2) Kitagawa Detector Tube - Isopropyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Isopropyl Ether (C6H14O) Kitagawa Detector Tube - Isopropyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
30 - 800 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U N-Decane (C10H22) Kitagawa Detector Tube - N-Decane Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 90 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U N-Nonane (C9H20) Kitagawa Detector Tube - N-Nonane Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 160 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U N-Undecane (C11H24) Kitagawa Detector Tube - N-Undecane Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 140 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Tert-Butanol (C4H10O) Kitagawa Detector Tube - Tert-Butanol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
111U Tert-Butyl Methyl Ether (C5H12O) (MTBE) Kitagawa Detector Tube - Tert-Butyl Methyl Ether (MTBE) Kitagawa Detector Tube
Typical Applications
Measurement Range
25 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
112SB Hydrogen Cyanide (Hydrocyanic Acid) (HCN) Kitagawa Detector Tube - Hydrogen Cyanide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 100 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
112SC Hydrogen Cyanide (Hydrocyanic Acid) (HCN) Kitagawa Detector Tube - Hydrogen Cyanide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.3 - 8 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
113SB n-Hexane (C6H14) Kitagawa Detector Tube - n-Hexane Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1400 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SB 2,2,4-Trimethyl Pentane (C8H18) Kitagawa Detector Tube - 2,2,4-Trimethyl Pentane Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 4000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SB Heptane (C7H16) Kitagawa Detector Tube - Heptane Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 2000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SB Isobutane (C4H10) Kitagawa Detector Tube - Isobutane Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SB Isobutylene (C4H8) Kitagawa Detector Tube - Isobutylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.03 - 2.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SB Methyl Cyclohexane (C7H14) Kitagawa Detector Tube - Methyl Cyclohexane Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 1600 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SB Pentane (C5H12) Kitagawa Detector Tube - Pentane Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1400 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
113SC n-Hexane (C6H14) Kitagawa Detector Tube - n-Hexane Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 800 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
117SB Nitrogen Dioxide (NO2) Kitagawa Detector Tube - Nitrogen Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 30.0 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
117SD Nitrogen Dioxide (NO2) Kitagawa Detector Tube - Nitrogen Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 1.0 ppmShelf Life
1.5 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
118SC Benzene (C6H6) Kitagawa Detector Tube - Benzene Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
118SD Benzene (C6H6) Kitagawa Detector Tube - Benzene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 75 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
118SE Benzene (in presence of Gasoline and/or Other Aromatic Hydrocarbons) Kitagawa Detector Tube - Benzene in Presence of Gasoline and/or Other Aromatic Hydrocarbons Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 80 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
119SA Methyl Alcohol (CH3OH) (Methanol) Kitagawa Detector Tube - Methyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 6,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
119U Methyl Alcohol (CH3OH) (Methanol) Kitagawa Detector Tube - Methyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
119U 1,4-Dioxane (C4H8O2) Kitagawa Detector Tube - 1,4-Dioxane Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
120SB Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.75 - 300 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
120SD Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 60 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
120SE2 Hydrogen Sulphide (H2S) Kitagawa Detector Tube *New - Hydrogen Sulphide Kitagawa Detector Tube *New
Typical Applications
Measurement Range
0.5 - 40 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
120SF Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
25 - 2000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
120U Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 6.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
121SA Phosphine (in Acetylene) Kitagawa Detector Tube - Phosphine in Acetylene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 800 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
121SB Phosphine (in Acetylene) Kitagawa Detector Tube - Phosphine in Acetylene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 90 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
121SE Phosphine Kitagawa Detector Tube *New - Phosphine Kitagawa Detector Tube *New
Typical Applications
Measurement Range
10 - 1400 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
121SD Phosphine (PH3) Kitagawa Detector Tube - Phosphine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.25 - 20.0 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
121U Phosphine (PH3) Kitagawa Detector Tube - Phosphine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 2.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
121U Arsine (AsH3) Kitagawa Detector Tube - Arsine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 2.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
122SA Ethylene Oxide (C2H4O) Kitagawa Detector Tube - Ethylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 4.0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
122SA Furan (C2H4O) Kitagawa Detector Tube - Furan Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 2.0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
122SA Isopropyl Alcohol (C3H8O) Kitagawa Detector Tube - Isopropyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 2,5 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
122SA Methyl Ethyl Ketone (C4H8O) Kitagawa Detector Tube - Methyl Ethyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 5,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
122SA Methyl Isobutyl Ketone (C6H12O) Kitagawa Detector Tube - Methyl Isobutyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 0,6 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
122SC Ethylene Oxide (C2H4O) Kitagawa Detector Tube - Ethylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 15 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
122SC Propylene Glycol (C3H8O2) Kitagawa Detector Tube - Propylene Glycol Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 50 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
122SC Propylene Oxide (C3H6O) Kitagawa Detector Tube - Propylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 70 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
122SM Ethylene Oxide (C2H4O) Kitagawa Detector Tube - Ethylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
124SA Toluene (C7H8) Kitagawa Detector Tube - Toluene Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
124SB Toluene (C7H8) Kitagawa Detector Tube - Toluene Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 100 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
125SA Propane (C3H8) Kitagawa Detector Tube - Propane Kitagawa Detector Tube
Typical Applications
Measurement Range
0,02 - 0,5 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
126SA Carbon dioxide (CO2) Kitagawa Detector Tube - Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 5,2 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
126SG Carbon dioxide (CO2) Kitagawa Detector Tube - Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,02 - 1,4 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
128SA Acrylonitrile (C3H3N) Kitagawa Detector Tube - Acrylonitrile Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 3,5 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
128SC Acrylonitrile (C3H3N) Kitagawa Detector Tube - Acrylonitrile Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 120 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
128SD Acrylonitrile (C3H3N) Kitagawa Detector Tube - Acrylonitrile Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 20 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
130U Ethyl Mercaptan (C2H6S) Kitagawa Detector Tube - Ethyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
130U Isopropyl Mercaptan (C3H8S) Kitagawa Detector Tube - Isopropyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
130U Methyl Mercaptan (CH4S) Kitagawa Detector Tube - Methyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
130U N-Propyl Mercaptan (C3H8S) Kitagawa Detector Tube - N-Propyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
130U tert-Butyl Mercaptan ((CH3)3CSH) Kitagawa Detector Tube - Tert-Butyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
132SA Vinyl Chloride (C2H3Cl) Kitagawa Detector Tube - Vinyl Chloride Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 1,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
132SB Vinyl Chloride (C2H3Cl) Kitagawa Detector Tube - Vinyl Chloride Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 500 ppmShelf Life
1.5 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
132SC Vinyl Chloride (C2H3Cl) Kitagawa Detector Tube - Vinyl Chloride Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 12.0 ppmShelf Life
Confirm the expiry date on the box with NOVEL.Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
133SB Acetaldehyde (C2H4O) Kitagawa Detector Tube - Acetaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 140 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
133SC Acetaldehyde (C2H4O) Kitagawa Detector Tube - Acetaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 30 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
134SA Trichloroethylene (C2HCl3) Kitagawa Detector Tube - Trichloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 300 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
134SB Trichloroethylene (C2HCl3) Kitagawa Detector Tube - Trichloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 36.8 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
135SA Tetrachloroethylene (C2HCl3) Kitagawa Detector Tube - Tetrachloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 300 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
135SB Tetrachloroethylene (C2HCl3) Kitagawa Detector Tube - Tetrachloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 10 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
135SM Tetrachloroethylene (C2HCl3) Kitagawa Detector Tube - Tetrachloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1250 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
138U Butyl Acetate (C6H12O2) Kitagawa Detector Tube - Butyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 400 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
139U Methyl Ethyl Ketone (C4H8O) Kitagawa Detector Tube - Methyl Ethyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
139U Diisobutyl Ketone (C9H18O) Kitagawa Detector Tube - Diisobutyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
139U Methyl Amyl Ketone (C7H14O) Kitagawa Detector Tube - Methyl Amyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
23 - 350 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
139U Methyl Ethyl Ketone (C4H8O) Kitagawa Detector Tube - Methyl Ethyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
139U Methyl Propyl Ketone (C5H10O) Kitagawa Detector Tube - Methyl Propyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
141SB Carbon Disulphide (CS2) Kitagawa Detector Tube - Carbon Disulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.8 - 50 ppmShelf Life
3 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
142S Mercury Vapour (Hg) Kitagawa Detector Tube - Mercury Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 10 mg/m3Shelf Life
3 YearsQuantity per Box
10 pcs/box
143SA Xylene (C8H10) Kitagawa Detector Tube - Xylene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 1000 ppmShelf Life
1.5 YearsQuantity per Box
10 pcs/box
143SB Xylene (C8H10) Kitagawa Detector Tube - Xylene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
146S Phosgene (COCl2) Kitagawa Detector Tube - Phosgene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 20 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
150U Isopropyl Alcohol (C3H8O) Kitagawa Detector Tube - Isopropyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
151U Propyl Acetate (C5H10O2) Kitagawa Detector Tube - Propyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
152S Chloroform (CHCl3) Kitagawa Detector Tube - Chloroform Kitagawa Detector Tube
Typical Applications
Measurement Range
23 - 500 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
153U Isobutyl Acetate (C6H12O2) Kitagawa Detector Tube - Isobutyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 400 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
153U Naphthalene (C10H8) Kitagawa Detector Tube - Naphthalene Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 400 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
156S Hydrogen Fluoride (HF) Kitagawa Detector Tube - Hydrogen Fluoride Kitagawa Detector Tube
Typical Applications
Measurement Range
0.17 - 30 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
157SD Methyl Bromide (CH3Br) Kitagawa Detector Tube - Methyl Bromide Kitagawa Detector Tube
Typical Applications
Insect fumigation for mills, warehouses, ships, crates, goods wagons; concentration control in grain fumigationMeasurement Range
0.1 - 22 ppmShelf Life
1 YearQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
158S Styrene (C8H8) Kitagawa Detector Tube - Styrene Kitagawa Detector Tube
Typical Applications
Measurement Range
2.5 - 300 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
158S Divinyl Benzene (C6H4(CHCH2)2) Kitagawa Detector Tube - Divinyl Benzene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 50 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
158S α-Pinene (C10H16) Kitagawa Detector Tube - α-Pinene Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 300 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
158SB Styrene (C8H8) Kitagawa Detector Tube - Styrene Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 100 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
159SA Oxygen (O2) Kitagawa Detector Tube - Oxygen Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 24 %Shelf Life
2 YearsQuantity per Box
5 pcs/box
159SB Oxygen (O2) Kitagawa Detector Tube - Oxygen Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 24 %Shelf Life
2 YearsQuantity per Box
5 pcs/box
162U Tetrahydrofuran (C4H8O) Kitagawa Detector Tube - Tetrahydrofuran Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 400Shelf Life
2 YearsQuantity per Box
10 pcs/box
171SB Formaldehyde (CH2O) Kitagawa Detector Tube - Formaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 35 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
171SC Formaldehyde (CH2O) Kitagawa Detector Tube - Formaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 4.0 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
173SA Hydrogen Chloride (HCl) Kitagawa Detector Tube - Hydrogen Chloride Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1200 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
174A Nitrogen Oxide and Nitrogen Dioxide (NO & NO2) Kitagawa Detector Tube - Nitrogen Oxide&Dioxide Separately Measurable Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 300 ppmShelf Life
2 YearsQuantity per Box
5 pcs/box
174B Nitrogen Oxide/Nitrogen Dioxide (NO & NO2) (in Flue Gas) Kitagawa Detector Tube - Nitrogen Oxide&Dioxide in Flue Gas Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 300 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
177SA Water Vapour (H2O) Kitagawa Detector Tube - Water Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
1.7 - 33.8 mg/LShelf Life
3 YearsQuantity per Box
10 pcs/box
179S Ethylbenzene (C8H10) Kitagawa Detector Tube - Ethyl Benzene Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
1.5 YearsQuantity per Box
10 pcs/box
180S Dichloromethane (CH2Cl2) Kitagawa Detector Tube - Dichloromethane Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1000 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
181S Aniline (C6H5NH2) Kitagawa Detector Tube - Aniline Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 30 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
182SB Ozone (O3) Kitagawa Detector Tube - Ozone Kitagawa Detector Tube
Typical Applications
Measurement Range
2.5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
183U Phenol (C6H6O) Kitagawa Detector Tube - Phenol Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 25.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
183U Cresol (C7H8O) Kitagawa Detector Tube - Cresol Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 25.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
184S Methyl Methacrylate (C5H8O2) Kitagawa Detector Tube - Methyl Methacrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 160 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
184S Allyl Alcohol (C3H6O) Kitagawa Detector Tube - Allyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 5000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
187S General Hydrocarbons Kitagawa Detector Tube - General Hydrocarbons Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1400 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
189U 2-Butanol (C4H10O) Kitagawa Detector Tube - 2-Butanol Kitagawa Detector Tube
Typical Applications
Measurement Range
4 - 300 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Ethyl Cellosolve© (C4H10O2) Kitagawa Detector Tube - Ethyl Cellosolve© Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U 1-Butanol (C4H10O) Kitagawa Detector Tube - 1-Butanol Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U 1-Propanol (C3H8O) Kitagawa Detector Tube - 1-Propanol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 300 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Butyl Cellosolve© (C6H14O2) Kitagawa Detector Tube - Butyl Cellosolve© Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Crotonaldehyde (C4H6O) Kitagawa Detector Tube - Crotolaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 40 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Diacetone Alcohol (C6H12O2) Kitagawa Detector Tube - Diacetone Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 250 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Dicyclopentadiene (C10H12) Kitagawa Detector Tube - Dicyclopentadiene Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 60 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Ethyl Cellosolve© (C6H12O3) Acetate Kitagawa Detector Tube - Ethyl Cellosolve© Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 150 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Furfural (C5H4O2) Kitagawa Detector Tube - Furfural Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 60 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
190U Isoprene (C5H8) Kitagawa Detector Tube - Isoprene Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 16 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Isopropyl Cellosolve© Kitagawa Detector Tube - Isopropyl Cellosolve© Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 350 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Mesityl Oxide (C6H10O) Kitagawa Detector Tube - Mesityl Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Methyl Cellosolve© (C3H8O2) Kitagawa Detector Tube - Methyl Cellosolve© Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Methyl Cellosolve© Acetate Kitagawa Detector Tube - Methyl Cellosolve© Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 120 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
190U Tetrahydrothiophene (C4H8S) Kitagawa Detector Tube - Tetrahydrothiophene Kitagawa Detector Tube
Typical Applications
Measurement Range
4 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
197U Cyclohexanone (C6H10O) Kitagawa Detector Tube - Cyclohexanone Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 100 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
197U 1-Methoxy-2-Propanol (C4H10O2) Kitagawa Detector Tube - 1-Methoxy-2-Propanol Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
197U Isophorone (C9H14O) Kitagawa Detector Tube - Isophorone Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 80 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
201SC Chloride Ion (Cl-) Kitagawa Detector Tube - Chloride Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 60 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
208U Isobutyl Alcohol (C4H10O) Kitagawa Detector Tube - Isobutyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
211U Butyl Acrylate (C7H12O2) Kitagawa Detector Tube - Butyl Acrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 60 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
211U Ethyl Acrylate (C5H8O2) Kitagawa Detector Tube - Ethyl Acrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 60 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
211U Isobutyl Acrylate (C7H12O2) Kitagawa Detector Tube - Isobutyl Acrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 60 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
211U Methyl Acrylate (C4H6O2) Kitagawa Detector Tube - Methyl Acrylate Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 60 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
215S p-Dichlorobenzene (C6H4Cl2) Kitagawa Detector Tube - p-Dichlorobenzene Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 150 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
219S Hydrazine (N2H4) Kitagawa Detector Tube - Hydrazine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 10 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
221SA N-Butane (C4H10) Kitagawa Detector Tube - N-Butane Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 0,6 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
222S Diethylamine (C4H11N) Kitagawa Detector Tube - Diethyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
222S Isopropylamine (C3H9N) Kitagawa Detector Tube - Isopropyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 12 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
222S Trimethylamine (C3H9N) Kitagawa Detector Tube - Trimethyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
227S Methylamine (CH3NH2) Kitagawa Detector Tube - Methyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
227S Ethylamine (C2H5NH2) Kitagawa Detector Tube - Ethyl Amine* Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
227S Dimethylamine ((CH3)2NH) Kitagawa Detector Tube - Dimethyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
229S N,N-Dimethylacetamide (C4H9NO) Kitagawa Detector Tube - N,N-Dimethylacetamide Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 70 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
232SA Ethylene Glycol (C2H6O2) Kitagawa Detector Tube - Ethylene Glycol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 250 mg/m3Shelf Life
1.5 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
233S Nitric Acid Vapour (HNO3) Kitagawa Detector Tube - Nitric Acid Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
237S Vinyl Acetate (C4H6O2) Kitagawa Detector Tube - Vinyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 120 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
237S Methyl Butyl Ketone (C6H12O) Kitagawa Detector Tube - Methyl Butyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 80 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
239S Carbonyl Sulphide (COS) Kitagawa Detector Tube - Carbonyl Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 60 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
245UL Methyl Isothiocyanate (C2H3NS) Kitagawa Detector Tube - Methyl Isothiocyanate Kitagawa Detector Tube
Typical Applications
Measurement Range
0.3 - 22 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
247S Hydrogen Peroxide (H2O2) Kitagawa Detector Tube - Hydrogen Peroxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10.0 ppmShelf Life
3 Years (Revised 01.2026)Storage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
301 Air Flow Indicator Kitagawa Detector Tube - Air Flow Indicator Tube Kitagawa Detector Tube
Typical Applications
Measurement Range
Shelf Life
Quantity per Box
10 pcs/box
603SPA Water Vapour (H2O) Kitagawa Detector Tube - Water Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 160 mg/m3Shelf Life
3 YearsQuantity per Box
10 pcs/box
77S Water Content in Solvent (H2S) Kitagawa Detector Tube - Water Content in Solvent Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 400 mg/LShelf Life
2 YearsQuantity per Box
10 pcs/box
102SA Acetone (C3H6O) Kitagawa Detector Tube - Acetone Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 5,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
102SA Tetrahydrofuran (C4H8O) Kitagawa Detector Tube - Tetrahydrofuran Kitagawa Detector Tube
Typical Applications
Measurement Range
0,2 - 5,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
102SC Acetone (C3H6O) Kitagawa Detector Tube - Acetone Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 4,0 %Shelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
103SA Sulphur Dioxide (SO2) Kitagawa Detector Tube - Sulphur Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 3,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
103SB Sulphur Dioxide (SO2) Kitagawa Detector Tube - Sulphur Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,02 - 0,3 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
103SF Sulphur Dioxide (SO2) Kitagawa Detector Tube - Sulphur Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,02 - 0,3 %Shelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
104U Ethanol (C2H5OH) Kitagawa Detector Tube - Ethyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1,000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
105SA Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
0,5 - 10 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
105SH Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
0,5 - 30 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
105SM Ammonia (NH3) Kitagawa Detector Tube - Ammonia Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 1,0 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
106B Carbon Monoxide (CO) (in the presence of Ethylene, colour intensity) Kitagawa Detector Tube - Carbon Monoxide (in the presence of Ethylene, colour intensity) Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1,000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
106SH Carbon Monoxide (CO) Kitagawa Detector Tube - Carbon Monoxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 2,0 %Shelf Life
1 YearQuantity per Box
10 pcs/box
106SS Carbon Monoxide (CO) Kitagawa Detector Tube - Carbon Monoxide Kitagawa Detector Tube
Typical Applications
Measurement Range
30 - 500 ppmShelf Life
3.5 YearsQuantity per Box
10 pcs/box
107SA Ethyl Ether ((C2H5)2O) Kitagawa Detector Tube - Ethyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
0,04 - 1,4 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
110S Gasoline Kitagawa Detector Tube - Gasoline Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 0,6 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
112SA Hydrogen Cyanide (HCN) Kitagawa Detector Tube - Hydrogen Cyanide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.01 - 3,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
113SA n-Hexane (C6H14) Kitagawa Detector Tube - n-Hexane Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 1,32 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
114 Bromide (Br) Kitagawa Detector Tube - Bromine Kitagawa Detector Tube
Typical Applications
Measurement Range
'1 - 20 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
115S Cyclohexane (C6H12) Kitagawa Detector Tube - Cyclohexane Kitagawa Detector Tube
Typical Applications
Measurement Range
0.01 - 0.6 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
118SB Benzene (C6H6) (in the presence of Gasoline and/or other aromatic hydrocarbons) Kitagawa Detector Tube - Benzene (in the presence of Gasoline and/or other aromatic hydrocarbons) Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 300 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
120SC Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1,600 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
120SH Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen Sulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 4.0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
120SM Hydrogen Sulphide (H2S) Kitagawa Detector Tube - Hydrogen SulphideKitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 1.2 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
120UH Hydrogen Sulphide (H2S) (ultra high range) Kitagawa Detector Tube - Hydrogen Sulphide (ultra high range) Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 20 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
121SG Phosphine (PH3) Kitagawa Detector Tube - Phosphine Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 150 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
121SH Phosphine (PH3) Kitagawa Detector Tube - Phosphine Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 3,200 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
121SS Phosphine (PH3) Kitagawa Detector Tube - Phosphine Kitagawa Detector Tube
Typical Applications
Measurement Range
200 - 6,000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
122SD Ethylene Oxide (C2H4O) Kitagawa Detector Tube - Ethylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 14.0 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
122SL Ethylene Oxide (C2H4O) Kitagawa Detector Tube - Ethylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 2,600 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
123S Dimethyl Ether (C2H6O) Kitagawa Detector Tube - Dimethyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 1,2 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
124SH Toluene (C7H8) Kitagawa Detector Tube - Toluene Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 3,000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
126B Carbon dioxide (CO2) Kitagawa Detector Tube - Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.03 - 0.7% 100 - 1,500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
126SB Carbon dioxide (CO2) Kitagawa Detector Tube - Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,021 - 1,0 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
126SH Carbon dioxide (CO2) (extra high range) Kitagawa Detector Tube - Carbon Dioxide (extra high range) Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 20 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
126UH Carbon dioxide (CO2) (ultra high range) Kitagawa Detector Tube - Carbon Dioxide (ultra high range) Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 50 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
128SB Acrylonitrile (C3H3N) Kitagawa Detector Tube - Acrylonitrile Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
129 Nickel Carbonyl (Ni(CO)4) Kitagawa Detector Tube - Nickel Carbonyl Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 700 ppmShelf Life
6 MonthsQuantity per Box
10 pcs/box
131 Inorganic Gas Qualitative Kitagawa Detector Tube - Inorganic Gas Qualitative Kitagawa Detector Tube
Typical Applications
Measurement Range
-Shelf Life
1 YearQuantity per Box
10 pcs/box
133A Acetaldehyde (C2H4O) Kitagawa Detector Tube - Acetaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
0,004 - 1,0 %Shelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
134SG Trichloroethylene (C2HCl3) Kitagawa Detector Tube - Trichloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 2,0 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
135SG Tetrachloroethylene (C2Cl4) Kitagawa Detector Tube - Tetrachloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0,1 - 2,0 %Shelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
136 Acrolein - Acrylic Aldehyde Kitagawa Detector Tube - Acrolein - Acryl Aldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
0,005 - 1,8 %Shelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
139SB Methyl Ethyl Ketone (C4H8O) Kitagawa Detector Tube - Methyl Ethyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 1,4 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
139SB Propyl Acetate (C5H10O2) Kitagawa Detector Tube - Propyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 1,4 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
139SB Isopropyl Acetate (C5H10O2) Kitagawa Detector Tube - Isopropyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 1,2 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
139SB Isobutyl Acetate (C5H10O2) Kitagawa Detector Tube - Isobutyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 1,4 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
139SB Butyl Acetate (C6H12O2) Kitagawa Detector Tube - Butyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 1,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
139SB 1,4-Dioxane (C4H8O2) Kitagawa Detector Tube - 1,4-Dioxane Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 2,5 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
140SA Arsine (AsH3) Kitagawa Detector Tube - Arsine Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 160 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
141SA Carbon Disulphide (CS2) Kitagawa Detector Tube - Carbon Disulphide Kitagawa Detector Tube
Typical Applications
Measurement Range
30 - 500 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
145SA 1,2-Dichloroethylene (C2H2Cl2) Kitagawa Detector Tube - 1,2-Dichloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
4.2 - 840 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
147S Carbon Tetrachloride (CCl4) Kitagawa Detector Tube - Carbon Tetrachloride Kitagawa Detector Tube
Typical Applications
Measurement Range
'5 - 60 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
155U Methyl Isobutyl Ketone (C6H12O) Kitagawa Detector Tube - Methyl Isobutyl Ketone Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 300 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
157JS Methyl Bromide (CH3Br) Kitagawa Detector Tube - Methyl Bromide Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 70 g/m3Shelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
157SA Methyl Bromide (CH3Br) Kitagawa Detector Tube - Methyl Bromide Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
3 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
160S Methyl Chloroform (C2H3Cl3) Kitagawa Detector Tube - Methyl Chloroform Kitagawa Detector Tube
Typical Applications
Measurement Range
15 - 400 ppmShelf Life
3 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
163SA Propylene Oxide (C3H6O) Kitagawa Detector Tube - Propylene Oxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0,05 - 5,0 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
164SA Methanethiol (CH4S) Kitagawa Detector Tube - Methyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 140 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
165SB Ethyl Mercaptan (C2H6S) Kitagawa Detector Tube - Ethyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
2.5 - 80 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
165SB Tert-Butyl Mercaptan ((CH3)3CSH) Kitagawa Detector Tube - Tert-Butyl Mercaptan Kitagawa Detector Tube
Typical Applications
Measurement Range
2.5 - 80 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
166S Ethylene Dibromide (C2H4Br2) Kitagawa Detector Tube - Ethylene Dibromide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 50 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
167S Hydrogen Selenide (H2Se) Kitagawa Detector Tube - Hydrogen Selenide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 600 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
168SA 1,3-Butadiene (C4H6) Kitagawa Detector Tube - 1,3-Butadiene Kitagawa Detector Tube
Typical Applications
Measurement Range
0,03 - 2,6 %Shelf Life
3 YearsQuantity per Box
10 pcs/box
168SB 1,3-Butadiene (C4H6) Kitagawa Detector Tube - 1,3-Butadiene Kitagawa Detector Tube
Typical Applications
Measurement Range
30 - 600 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
168SC 1,3-Butadiene (C4H6) Kitagawa Detector Tube - 1,3-Butadiene Kitagawa Detector Tube
Typical Applications
Measurement Range
2.5 - 100 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
168SE 1,3-Butadiene (C4H6) Kitagawa Detector Tube - 1,3-ButadieneKitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 10.00 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
169S Chloroprene (C4H5Cl) Kitagawa Detector Tube - Chloroprene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 20 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
171SA Formaldehyde (CH2O) Kitagawa Detector Tube - Formaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 1,500 ppmShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
172S Chloropicrin (CCl3NO2) Kitagawa Detector Tube - Chloropicrin Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 16.0 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
175SA Nitrogen Oxide (NOX) Kitagawa Detector Tube - Nitrogen Oxides Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 250 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
175SH Nitrogen Oxide (NOX) Kitagawa Detector Tube - Nitrogen Oxides Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 2,500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
176SC Methyl Iodide (CH3I) Kitagawa Detector Tube - Methyl Iodide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.4 - 50 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
176UH Methyl Iodide (CH3I) Kitagawa Detector Tube - Methyl Iodide Kitagawa Detector Tube
Typical Applications
Measurement Range
500 - 15,000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
177UL Water Vapour (H2O) Kitagawa Detector Tube - Water Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 80 LB/MMCFShelf Life
3 YearsQuantity per Box
10 pcs/box
177UR Water Vapour (H2O) Kitagawa Detector Tube - Water Vapour Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 12 LB/MMCFShelf Life
3 YearsQuantity per Box
10 pcs/box
178SB Chlorobenzene (C6H5Cl) Kitagawa Detector Tube - Chlorobenzene Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 140 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
182SA Ozone (O3) Kitagawa Detector Tube - Ozone Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1,000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
185S Propylene (C3H6) Kitagawa Detector Tube - Propylene Kitagawa Detector Tube
Typical Applications
Measurement Range
50 - 1,000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
186 Organic Gas Qualitative Kitagawa Detector Tube - Organic Gas Checker Kitagawa Detector Tube
Typical Applications
Measurement Range
-Shelf Life
3 YearsQuantity per Box
10 pcs/box
186B Organic Gas Qualitative Kitagawa Detector Tube - Organic Gas Qualitative Kitagawa Detector Tube
Typical Applications
Measurement Range
-Shelf Life
2 YearsQuantity per Box
10 pcs/box
188U Isopentyl Acetate (C7H14O2) Kitagawa Detector Tube - Isopentyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 400 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
192S Epichlorohydrin (C3H5ClO) Kitagawa Detector Tube - Epichlorohydrine Kitagawa Detector Tube
Typical Applications
Measurement Range
'5 - 50 ppmShelf Life
1 YearQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
193S Methyl Styrene (C9H10) Kitagawa Detector Tube - Methyl Styrene Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
194S 1,3-Dichloropropane (C3H6Cl2) Kitagawa Detector Tube - 1,3-Dichloropropane Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 500 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)196S N,N-Dimethylformamide (C₃H₇NO) Kitagawa Detector Tube - N,N-Dimethylformamide Kitagawa Detector Tube
Typical Applications
Measurement Range
'1 - 30 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
198U Methyl Cyclohexanone (C7H12O ) Kitagawa Detector Tube - Methyl Cyclohexanone Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
199U Methyl Cyclohexanol (CH3C6H10OH) Kitagawa Detector Tube - Methyl Cyclohexanol Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
200SA Sulphide Ion (S2−) Kitagawa Detector Tube - Sulphide Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 1,000 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
200SB Sulphide Ion (S2−) Kitagawa Detector Tube - Sulphide Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
201SA Chloride Ion (Cl-) Kitagawa Detector Tube - Chloride Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 2,000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
201SB Sulphide Ion (S2−) Kitagawa Detector Tube - Sulphide Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
203S Copper Ion (Cu2+) Kitagawa Detector Tube - Copper Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 100 mg/LShelf Life
1 YearQuantity per Box
10 pcs/box
204S Cyanide Ion (CN-) Kitagawa Detector Tube - Cyanide Ion Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 5 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box205SL Salinity (NaCl) Kitagawa Detector Tube - Salinity Kitagawa Detector Tube
Typical Applications
Measurement Range
0,01 - 0,80 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
206U Cyclohexanol (C6H12O) Kitagawa Detector Tube - Cyclohexanol Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 500 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
209U Isopentyl Alcohol (C5H12O) Kitagawa Detector Tube - Isopentyl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
210U Amyl Acetate (C7H14O2) Kitagawa Detector Tube - Pentyl Acetate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 200 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
213S Triethylamine (C6H15N) Kitagawa Detector Tube - Triethyl Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
'0.5 - 20 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
214S o-Dichlorobenzene (C6H4Cl2) Kitagawa Detector Tube - o-Dichlorobenzene Kitagawa Detector Tube
Typical Applications
Measurement Range
5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
223S 2,2-Dichloroethyl Ether (C4H8Cl2O) Kitagawa Detector Tube - 2,2-Dichloroethyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
'2 - 30 ppmShelf Life
1 YearQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
224SA Monoethanolamine (C2H7NO) Kitagawa Detector Tube - Monoethanol Amine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 50 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
230SA 1,2-Dichloroethane (C2H4Cl2) Kitagawa Detector Tube - 1,2-Dichloroethane Kitagawa Detector Tube
Typical Applications
Measurement Range
'5 - 50 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
3x5 pcs/box (Two tubes are used per measurement)
232SB Ethylene Glycol (C2H6O2) Kitagawa Detector Tube - Ethylene Glycol Kitagawa Detector Tube
Typical Applications
Measurement Range
3 - 40 mg/m3Shelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
234SA Residual Free Chlorine (Cl2) Kitagawa Detector Tube - Free Residual Chlorine Kitagawa Detector Tube
Typical Applications
Measurement Range
0.4 - 5 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
235SA 1,1-Dichloroethane (C2H4Cl2) Kitagawa Detector Tube - 1,1-DichloroethaneKitagawa Detector Tube
Typical Applications
Measurement Range
10 - 160 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
3x5 pcs/box (Three tubes are used per measurement)
236SA Trichloroethane (C2H3Cl3) Kitagawa Detector Tube - Trichloroethane Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 100 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
3x5 pcs/box (Three tubes are used per measurement)
236SA Tetrachloroethane Kitagawa Detector Tube - Tetrachloroethane* Kitagawa Detector Tube
Typical Applications
Measurement Range
20-80 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
3x5 pcs/box (Three tubes are used per measurement)
238S Furfuryl Alcohol (C5H6O2) Kitagawa Detector Tube - Furfuryl Alcohol Kitagawa Detector Tube
Typical Applications
Measurement Range
'5 - 25 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
240S Silane (SiH4) Kitagawa Detector Tube - Silane Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 50 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
242S Diborane (B2H6) Kitagawa Detector Tube - Diborane Kitagawa Detector Tube
Typical Applications
Measurement Range
0.02 - 5.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
242S Hydrogen Selenide Kitagawa Detector Tube - Hydrogen selenide Kitagawa Detector Tube
Typical Applications
Measurement Range
1 - 600 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
245UH Methyl Isothiocyanate (C2H3NS) Kitagawa Detector Tube - Methyl Isothiocyanate Kitagawa Detector Tube
Typical Applications
Measurement Range
200 - 10,000 ppmShelf Life
3 YearsQuantity per Box
10 pcs/box
245UM Methyl Isothiocyanate (C2H3NS) Kitagawa Detector Tube - Methyl Isothiocyanate Kitagawa Detector Tube
Typical Applications
Measurement Range
10 - 1,500 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
248U Ethyl Tert-Butyl Ether (C6H14O) Kitagawa Detector Tube - Ethyl-tert-Butyl Ether Kitagawa Detector Tube
Typical Applications
Measurement Range
'1 - 60 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
249S 1,3-Dichloropropene (C3H4Cl2) Kitagawa Detector Tube - 1,3-Dichloropropene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 10 ppmShelf Life
3 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
251U Diesel Fuel Kitagawa Detector Tube - Diesel Fuel Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 30 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
280S Acetylene-Ethylene Separation Kitagawa Detector Tube - Acetylene-Ethylene Separation Kitagawa Detector Tube
Typical Applications
Measurement Range
C2H2 20 - 300 ppm, C2H4 200 - 2,000 ppmShelf Life
1 YearQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
281S Oxygen-Carbon Dioxide Separation Kitagawa Detector Tube - Oxygen-Carbon Dioxide Seperation Kitagawa Detector Tube
Typical Applications
Measurement Range
O2 2 - 10 %, CO2 1 - 20 %Shelf Life
1.5 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
282S Hydrogen Sulphide-Mercaptan Separation Kitagawa Detector Tube - Hydrogen Sulphide-Mercaptans Seperation Kitagawa Detector Tube
Typical Applications
Measurement Range
H2S 1 - 30 ppm, R.SH 0.5 - 5 ppmShelf Life
2 YearsQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
290CN Hydrocyanic Acid (in Blood) Kitagawa Detector Tube - Hydrogen Cyanide in Blood Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 30 mg/LShelf Life
2 YearsStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
290CO Carbon Monoxide (in Blood) Kitagawa Detector Tube - Carbon Monoxide in Blood Kitagawa Detector Tube
Typical Applications
Measurement Range
20 - 90 % COHbShelf Life
1 YearQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
290EA Ethanol (in Blood) Kitagawa Detector Tube - Ethyl Alcohol in Blood Kitagawa Detector Tube
Typical Applications
Measurement Range
0.2 - 2.0 mg/mLShelf Life
1 YearQuantity per Box
2x5 pcs/box (Two tubes are used per measurement)
290HS Hydrogen Sulphide (in Blood) Kitagawa Detector Tube - Hydrogen Sulphide in Blood Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 1.0 mg/mLShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
2x5 pcs/box (Two tubes are used per measurement)
600SP Compressed Breathing Air Carbon Monoxide Kitagawa Detector Tube - Carbon Monoxide Kitagawa Detector Tube
Typical Applications
Measurement Range
2.5 - 100 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
601SP Compressed Breathing Air Carbon Dioxide Kitagawa Detector Tube - Carbon Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
100 - 3,000 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
604SP Compressed Breathing Air Oxygen Kitagawa Detector Tube - Oxygen Kitagawa Detector Tube
Typical Applications
Measurement Range
2 - 24 %Shelf Life
2 YearsQuantity per Box
10 pcs/box
710 Formaldehyde Kitagawa Detector Tube - Formaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
0.01 - 0.48 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
20 pcs/box
710A Formaldehyde Kitagawa Detector Tube - Formaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
0.5 - 2.0 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
20 pcs/box
713 Formaldehyde Kitagawa Detector Tube - Formaldehyde Kitagawa Detector Tube
Typical Applications
Measurement Range
0.01 - 0.50 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
20 pcs/box
721 Toluene Kitagawa Detector Tube - Toluene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 1.0 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
721 Xylene Kitagawa Detector Tube - Xylene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.1 - 1.4 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
721 Ethyl Benzene Kitagawa Detector Tube - Ethyl Benzene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 1.2 ppmShelf Life
1 YearStorage
Refrigerate at 0–10 °C. Source ↗
Quantity per Box
10 pcs/box
730 p-Dichlorobenzene Kitagawa Detector Tube - p-Dichlorobenzene Kitagawa Detector Tube
Typical Applications
Measurement Range
0.01 - 0.40 ppmShelf Life
1 YearQuantity per Box
10 pcs/box
740 Nitrogen Dioxide Kitagawa Detector Tube - Nitrogen Dioxide Kitagawa Detector Tube
Typical Applications
Measurement Range
0.01 - 0.2 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
750 Trichloroethylene Kitagawa Detector Tube - Trichloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
30 - 920 μg/m3Shelf Life
1 YearQuantity per Box
2x10 pcs/box (Two tubes are used per measurement)
760 Tetrachloroethylene Kitagawa Detector Tube - Tetrachloroethylene Kitagawa Detector Tube
Typical Applications
Measurement Range
30 - 920 μg/m3Shelf Life
1 YearQuantity per Box
2x10 pcs/box (Two tubes are used per measurement)
770 Hydrogen Fluoride Kitagawa Detector Tube - Hydrogen FluorideKitagawa Detector Tube
Typical Applications
Measurement Range
0.05 - 1.0 ppmShelf Life
2 YearsQuantity per Box
10 pcs/box
800B Charcoal Kitagawa Detector Tube - Charcoal Tube Kitagawa Detector Tube
Typical Applications
Measurement Range
-Shelf Life
-Quantity per Box
20 pcs/box
801 Silica Gel Kitagawa Detector Tube - Silica-Gel Tube Kitagawa Detector Tube
Typical Applications
Measurement Range
-Shelf Life
-Quantity per Box
10 pcs/box
810 Silica Gel Sorbent Tube for Aldehydes and Ketones - Aldehydes and Ketones for Silica Gel Sorbent Tube
Typical Applications
Measurement Range
-Shelf Life
-Quantity per Box
20 pcs/box