Customer need
Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.
NOVEL · Product and System Solutions
Gas Detectors and Industrial Measurement Instruments

Provided via the internal siren on certain models.
From need to solution
CETCI LPT Series: selection starts with the measurement or system output your team needs for its decision.
Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.
Readings, alarm states and supported outputs from the chosen sensor configuration provide information to the monitoring system.
Select sensors, locations and alarm response procedures according to the gas, potential release source and site conditions; one sensor does not cover every gas.

| Number of Sensors | 1 unit |
|---|---|
| Detected Gas | Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3) |
| Externally Addable Sensors*1 | |
| Display | Monochrome LED indicator |
| Protection Class | IP54 with optional splash barrier |
| Alarm Details | |
| Connection Outputs | 4-20mA |
| Certificates | CSA-C22.2 No. 205-M1983 (R2009) UL508 (Edition 17):2007 EMC Directive 2004/108/EC EN 50270:2006, Type 1 EN61010, FCC. RoHS compliant circuit boards |
| Operating Temperature/Humidity | -20°C to +40°C, 15% to 90% Relative Humidity |
| Power Supply | 2-wire/3-wire: 16 - 30 VDC, 3W, Class 2 4-wire: 12 - 27 VAC, 50-60 Hz, 3VA, Class 2 |
| Dimensions and Weight | 127 x 127 x 48.5 mm, 400g |
| Optional Accessories | Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, external pump unit |
*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone.
Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.
| Number of Sensors | 1 unit |
|---|---|
| Detected Gas | Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Ethylene (C2H4), Ethylene Oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrocyanic Acid (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Methane (CH4), Propane (C3H8), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur Dioxide (SO2), TVOC, CFC Gases |
| Externally Addable Sensors*1 | Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC |
| Display | LCD Display |
| Protection Class | IP54 with optional splash barrier |
| Alarm Details | Built-in 90dB Siren |
| Connection Outputs | 4-20mA or 0-10 volts |
| Certificates | CSA-C22.2 No. 205-M1983 (R2009) UL508 (Edition 17):2007 EMC Directive 2004/108/EC EN 50270:2006, Type 1 EN61010, FCC. RoHS compliant circuit boards |
| Operating Temperature/Humidity | -20°C to +40°C, 15% to 90% Relative Humidity (-40°C operation with optional internal heater) |
| Power Supply | 3-wire: 16 - 30 VDC, 3W, Class 2 4-wire: 12 - 27 VAC, 50-60 Hz, 3VA, Class 2 |
| Dimensions and Weight | 127 x 127 x 53 mm, 400g |
| Optional Accessories | Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, internal heater, magnetic wand, external siren, strobe, external sensor (ESH-A), external pump unit |
*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone.
Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.
| Number of Sensors | 3 units (2 internal + 1 external ESH-A)*1 |
|---|---|
| Detected Gas | Carbon Monoxide (CO), Nitrogen Dioxide (NO2) |
| Externally Addable Sensors*1 | Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC |
| Display | LCD Display |
| Protection Class | IP54 with optional splash barrier |
| Alarm Details | |
| Connection Outputs | Modbus® RS-485 RTU*2 |
| Certificates | CSA-C22.2 No. 205-M1983 (R2009) UL508 (Edition 17):2007 EMC Directive 2004/108/EC EN 50270:2006, Type 1 EN61010, FCC. RoHS compliant circuit boards |
| Operating Temperature/Humidity | -20°C to +40°C, 15% to 90% Relative Humidity |
| Power Supply | 16 - 30 VDC, 3W, Class 2 |
| Dimensions and Weight | 127 x 127 x 71 mm, 400g |
| Optional Accessories | Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, external siren, external pump unit |
*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone.
Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.
| Number of Sensors | 3 units (2 internal + 1 external ESH-A)*1 |
|---|---|
| Detected Gas | Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Ethylene (C2H4), Ethylene Oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrocyanic Acid (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur Dioxide (SO2) |
| Externally Addable Sensors*1 | Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC |
| Display | LCD Display |
| Protection Class | IP54 with optional splash barrier |
| Alarm Details | Built-in 90dB Siren |
| Connection Outputs | Modbus® RS-485 RTU*2 |
| Certificates | CSA-C22.2 No. 205-M1983 (R2009) UL508 (Edition 17):2007 EMC Directive 2004/108/EC EN 50270:2006, Type 1 EN61010, FCC. RoHS compliant circuit boards |
| Operating Temperature/Humidity | -20°C to +40°C, 15% to 90% Relative Humidity (-40°C operation with optional internal heater) |
| Power Supply | 16 - 30 VDC, 3W, Class 2 12 - 27 VAC, 50-60 Hz, 3VA, Class 2 |
| Dimensions and Weight | 127 x 127 x 71 mm, 400g |
| Optional Accessories | Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, internal heater, magnetic wand, PID sensor maintenance kit, external siren, strobe, external sensor (ESH-A), external pump unit |
*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone.
Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.
| Number of Sensors | 3 units (2 internal + 1 external ESH-A)*1 |
|---|---|
| Detected Gas | Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Ethylene (C2H4), Ethylene Oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrocyanic Acid (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur Dioxide (SO2) |
| Externally Addable Sensors*1 | Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC |
| Display | Monochrome LED display |
| Protection Class | IP54 with optional splash barrier |
| Alarm Details | |
| Connection Outputs | BACnet® MS/TP*3 |
| Certificates | CSA-C22.2 No. 205-M1983 (R2009) UL508 (Edition 17):2007 EMC Directive 2004/108/EC EN 50270:2006, Type 1 EN61010, FCC, BTL. RoHS compliant circuit boards |
| Operating Temperature/Humidity | -20°C to +40°C, 15% to 90% Relative Humidity |
| Power Supply | 16 - 30 VDC, 3W, Class 2 12 - 27 VAC, 50-60 Hz, 3VA, Class 2 |
| Dimensions and Weight | 127 x 127 x 71 mm, 400g |
| Optional Accessories | Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, internal heater, magnetic wand, PID sensor maintenance kit, external siren, strobe, external sensor (ESH-A), external pump unit |
*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone.
Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.
Single Channel, Optionally Attachable External Sensors
Practical and Durable Construction
IP54 Ingress Protection Rating with Optional Splash Barrier
Easy Operation with Legible LCD Screen
Easy Menu Navigation Supported by Magnetic Wand
Wide Sensor Selection
Stand-Alone System
Firmware Monitoring Sensor Life
Adaptability to Diverse Operating Applications
Optional Internal Heater for Low-Temperature Environments
Optional Calibration Kit
You can examine product details and technical specifications by selecting an alternative suited to your requirements.
Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.
Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.
NOVEL technical support
A draft opens in your email client with the subject header of the relevant product or category.