NOVEL · Product and System Solutions

CETCI LPT Series

Gas Detectors and Industrial Measurement Instruments

CETCI LPT Series product image

Fixed Gas Detector, Wide Range of Sensor and Infrastructure Options, Models with or without Display Options


Provided via the internal siren on certain models.

Request a Quote from NOVEL ↗

From need to solution

Establish continuous monitoring at critical points

CETCI LPT Series: selection starts with the measurement or system output your team needs for its decision.

01

Customer need

Facilities need visibility of target-gas accumulation or changes in oxygen at selected locations.

02

Product output

Readings, alarm states and supported outputs from the chosen sensor configuration provide information to the monitoring system.

03

Decision supported

Select sensors, locations and alarm response procedures according to the gas, potential release source and site conditions; one sensor does not cover every gas.



Gas Detection and Standards Approach

Fixed gas detection approach: Target gas, sensor technology, measuring range, alarm objective, 4–20 mA/RS485/BACnet/Modbus integration, and area classification must be addressed together. The EN/IEC 60079-29 series for flammable gases, EN 45544 for toxic gases, EN 50104 for oxygen measurement, and EN 50271 for electronic control functions can be referenced according to the application. Claims of conformity to these standards must be verified on a model and sensor configuration basis through manufacturer documentation.

Product Videos

Product overview video
Product overview video
Watch Video ↗

Technical Specifications

LPT

Technical Specifications

Number of Sensors 1 unit
Detected Gas Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3)
Externally Addable Sensors*1
Display Monochrome LED indicator
Protection Class IP54 with optional splash barrier
Alarm Details
Connection Outputs 4-20mA
Certificates CSA-C22.2
No. 205-M1983 (R2009)
UL508 (Edition 17):2007
EMC Directive 2004/108/EC
EN 50270:2006, Type 1
EN61010, FCC.
RoHS compliant circuit boards
Operating Temperature/Humidity -20°C to +40°C, 15% to 90% Relative Humidity
Power Supply 2-wire/3-wire: 16 - 30 VDC, 3W, Class 2
4-wire: 12 - 27 VAC, 50-60 Hz, 3VA, Class 2
Dimensions and Weight 127 x 127 x 48.5 mm, 400g
Optional Accessories Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, external pump unit

*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone. Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.

LPT-A
Number of Sensors 1 unit
Detected Gas Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Ethylene (C2H4), Ethylene Oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrocyanic Acid (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Methane (CH4), Propane (C3H8), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur Dioxide (SO2), TVOC, CFC Gases
Externally Addable Sensors*1 Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC
Display LCD Display
Protection Class IP54 with optional splash barrier
Alarm Details Built-in 90dB Siren
Connection Outputs 4-20mA or 0-10 volts
Certificates CSA-C22.2
No. 205-M1983 (R2009)
UL508 (Edition 17):2007
EMC Directive 2004/108/EC
EN 50270:2006, Type 1
EN61010, FCC.
RoHS compliant circuit boards
Operating Temperature/Humidity -20°C to +40°C, 15% to 90% Relative Humidity (-40°C operation with optional internal heater)
Power Supply 3-wire: 16 - 30 VDC, 3W, Class 2
4-wire: 12 - 27 VAC, 50-60 Hz, 3VA, Class 2
Dimensions and Weight 127 x 127 x 53 mm, 400g
Optional Accessories Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, internal heater, magnetic wand, external siren, strobe, external sensor (ESH-A), external pump unit

*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone. Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.

LPT-P
Number of Sensors 3 units (2 internal + 1 external ESH-A)*1
Detected Gas Carbon Monoxide (CO), Nitrogen Dioxide (NO2)
Externally Addable Sensors*1 Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC
Display LCD Display
Protection Class IP54 with optional splash barrier
Alarm Details
Connection Outputs Modbus® RS-485 RTU*2
Certificates CSA-C22.2
No. 205-M1983 (R2009)
UL508 (Edition 17):2007
EMC Directive 2004/108/EC
EN 50270:2006, Type 1
EN61010, FCC.
RoHS compliant circuit boards
Operating Temperature/Humidity -20°C to +40°C, 15% to 90% Relative Humidity
Power Supply 16 - 30 VDC, 3W, Class 2
Dimensions and Weight 127 x 127 x 71 mm, 400g
Optional Accessories Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, external siren, external pump unit

*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone. Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.

LPT-M
Number of Sensors 3 units (2 internal + 1 external ESH-A)*1
Detected Gas Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Ethylene (C2H4), Ethylene Oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrocyanic Acid (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur Dioxide (SO2)
Externally Addable Sensors*1 Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC
Display LCD Display
Protection Class IP54 with optional splash barrier
Alarm Details Built-in 90dB Siren
Connection Outputs Modbus® RS-485 RTU*2
Certificates CSA-C22.2
No. 205-M1983 (R2009)
UL508 (Edition 17):2007
EMC Directive 2004/108/EC
EN 50270:2006, Type 1
EN61010, FCC.
RoHS compliant circuit boards
Operating Temperature/Humidity -20°C to +40°C, 15% to 90% Relative Humidity (-40°C operation with optional internal heater)
Power Supply 16 - 30 VDC, 3W, Class 2 12 - 27 VAC, 50-60 Hz, 3VA, Class 2
Dimensions and Weight 127 x 127 x 71 mm, 400g
Optional Accessories Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, internal heater, magnetic wand, PID sensor maintenance kit, external siren, strobe, external sensor (ESH-A), external pump unit

*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone. Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.

LPT-B
Number of Sensors 3 units (2 internal + 1 external ESH-A)*1
Detected Gas Ammonia (NH3), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Ethylene (C2H4), Ethylene Oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrocyanic Acid (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur Dioxide (SO2)
Externally Addable Sensors*1 Methane (CH4), Propane (C3H8), Hydrogen (H2), TVOC
Display Monochrome LED display
Protection Class IP54 with optional splash barrier
Alarm Details
Connection Outputs BACnet® MS/TP*3
Certificates CSA-C22.2
No. 205-M1983 (R2009)
UL508 (Edition 17):2007
EMC Directive 2004/108/EC
EN 50270:2006, Type 1
EN61010, FCC, BTL.
RoHS compliant circuit boards
Operating Temperature/Humidity -20°C to +40°C, 15% to 90% Relative Humidity
Power Supply 16 - 30 VDC, 3W, Class 2 12 - 27 VAC, 50-60 Hz, 3VA, Class 2
Dimensions and Weight 127 x 127 x 71 mm, 400g
Optional Accessories Splash barrier*4, splash barrier for sticky gases*5, calibration adapter clip, calibration kit (for 17, 34, 58, 74, 100L cylinders, 0.5 LPM flow regulator and adapter for 17L cylinder), steel protective cage, internal heater, magnetic wand, PID sensor maintenance kit, external siren, strobe, external sensor (ESH-A), external pump unit

*1 with ESH-A external gas detector
*2 Modbus is a trademark of Gould Inc. Corporation.
*3 BACnet is a trademark of American Society of Heating.
*4 The splash barrier is not used for LPT series units used in measuring sticky gases such as chlorine, hydrochloric acid, and ozone. Its use causes incorrect gas concentration measurements.
*5 Dedicated to sticky gases (chlorine, hydrochloric acid, ozone); cannot be used for LPT series containing other gas sensors.

Product Specifications

  • Single Channel, Optionally Attachable External Sensors

  • Practical and Durable Construction

  • IP54 Ingress Protection Rating with Optional Splash Barrier

  • Easy Operation with Legible LCD Screen

  • Easy Menu Navigation Supported by Magnetic Wand

  • Wide Sensor Selection

  • Stand-Alone System

  • Firmware Monitoring Sensor Life

  • Adaptability to Diverse Operating Applications

  • Optional Internal Heater for Low-Temperature Environments

  • Optional Calibration Kit

Product Documents

Sectors

Alternative Products

You can examine product details and technical specifications by selecting an alternative suited to your requirements.

Frequently Asked Questions

What information is needed to select CETCI LPT Series?

Describe the measurement or communication task, operating environment, required range or capacity and recording needs. NOVEL can help review the model and configuration information on this page.

Where can I find accessories and technical documents?

Review the specifications, documents and any accessories sections on this page. Include model, quantity and intended use in your quotation request, and confirm compatibility before ordering.

NOVEL technical support

For your application,
let us select the right solution together.

Request a Quote from NOVEL ↗

A draft opens in your email client with the subject header of the relevant product or category.