One concept frequently encountered in professional life is Industrial Hygiene.
In this article, we address the scope of Industrial Hygiene and the characteristics of airborne contaminants within this context. Please refer to our other articles for information on additional components of Industrial Hygiene, such as noise, thermal comfort, lighting, vibration, and electromagnetic pollution, as well as the methods and protocols used to measure these parameters.
What is Occupational Hygiene? Occupational Hygiene: A scientific discipline aimed at anticipating, recognising, evaluating, and controlling conditions that compromise worker health, leading to illness or accidents. Examples of conditions compromising worker health include air pollution (dust, gas), noise, vibration, thermal conditions, inadequate lighting, electromagnetic pollution, radiation, etc. Occupational Hygienist: Identifies and applies necessary methods and standards to conduct assessments in the field of occupational hygiene. What are Air Pollutants? We can classify air pollutants by type as dust, fume, soot, gas, vapour, and fibre (asbestos, etc.).
Let us define the air pollutants we will focus on in this article; AEROSOL: The general term for liquid or solid particles suspended in ambient air. DUST: Small solid particles. Dust can be generated by pulverisation or grinding of solid matter, or through any other mechanical process. Large particles can be cleared by the respiratory system. Examples of mechanisms of action include: lead dust causes systemic damage via the bloodstream; grain dust causes dust explosions if it reaches a specific concentration. Coal dust can be cited as another dust with an exceptionally high explosion potential. If coal dust accumulates above specific concentrations, it leads to explosions. As a precaution, inertisation with rock dust is applied. This inertisation process can be measured using the CDEM-1000 Coal Dust Explosibility Meter developed by Sensidyne.

Watch Video ↗
FIBRE: Briefly, it can be defined as solid particles whose length exceeds their diameter. Large fibres are cleared by respiration, whereas fine fibres irritate the lungs. A typical example is asbestos fibres. Whilst asbestos sampling and analysis is a comprehensive subject in its own right, sampling can be successfully carried out using Sensidyne Gilian pumps.
Please click here for Sensidyne’s Gilian BDXII pump, used specifically for Asbestos and Heavy Metal Sampling.Exposure Limits, General Approaches Permissible Exposure Limits (PEL) vary depending on the substance of exposure as well as across different standards. Examples of these international standards include ACGIH (American Conference of Governmental Industrial Hygienists), NIOSH, OSHA, etc. Exposure limits are determined based on exposure durations;
STEL (Short Term Exposure Limit): Short-term exposure limit, based on a 15-minute exposure.
TWA (Time-Weighted Average): Time-weighted average, based on an 8-hour period.
TLV (Threshold Limit Value): Threshold limit value, taking shift-based exposure into account.

Watch Video ↗
The most critical point in applying this method is the sampling heads used for air sampling. If dust sampling is to be carried out, a filter suitable for the sampling environment and dust type must be used. Filters can be selected based on factors such as static electricity, moisture sensitivity, chemical incompatibility, etc. In occupational safety studies, both ambient dust and exposure measurements are performed; however, exposure measurements must take priority. Therefore, exposure zones must be taken into account during sampling. Examining the relationship between inhaled dust fraction size and exposure zone reveals the following data;
Inhalable (upper respiratory tract): Particles of 100 microns and below
Thoracic (middle respiratory tract = chest): 10 microns and below
Respirable (deep alveolar region of the lungs): 4 microns and below
As can be seen from this, as dust particle size decreases, the hazard to worker health increases. Therefore, taking inhaled dust fraction size into account in sampling is critical. The primary accessory used for this purpose is the cyclone sampling head.
Cyclone Dust Sampling Head
Flow rate may vary depending on the type of Cyclone Dust Sampling Head; e.g. 1.7 L/min is optimal for the Nylon Cyclone Dorr-Oliver. This flow rate is determined based on the optimum flow to separate the targeted 4-micron respirable dust. In certain circumstances, sampling over shortened durations may be required, running at a flow rate of 4.0 L/min using dedicated cyclone sampling heads. All flow rates must be set according to NIOSH or the applicable standard.
Click the product link for the Cyclone sampling heads shown as examples in the image and much more.
IOM (Inhalable Dust Sampler) Dust Sampling Head
If ambient dust or inhalable (upper respiratory tract) assessments are to be conducted, the most suitable accessory is the Inhalable Dust Sampler head, abbreviated as IOM. The ideal operating flow rate for these samplers is 2.2 L/min. The sampling head flow rate must be calibrated in accordance with NIOSH or the standard used.
Click the product link for the IOM (Inhalable Dust Sampler) sampling heads shown as examples in the image and much more.
Other Air Sampling Accessories
If sampling is to be conducted for the measurement of VOCs (Volatile Organic Compounds) and other toxic gases, sorbent tubes, passive samplers, impingers, and similar collection media appropriate for these analytes can be used.
Click here for all Occupational Safety Air Sampling Accessories.
As NOVEL, we supply and distribute gas and dust air sampling apparatus.
Air Sampling Pump Flow Calibrators
Another key component in the Gravimetric Sampling Method consists of verification apparatus, rotameters, and Primary – Secondary Flow Calibrators, which ensure measurements are performed professionally and enable flow rate calibration.
Flow calibrators are reference instruments that must be used to verify the flow rate of the pump used in sampling prior to operation, adjust for any drift, and re-check post-sampling to demonstrate that the sampling was completed within the specified flow range.
Click here for information regarding the Air Flow Calibrators shown as examples in the image.

Watch Video ↗
In summary, if a healthy working environment is targeted and preventative measures for worker safety are prioritised, the initial step towards these objectives is conducting measurements using correct methods and appropriate instrumentation. In this article, we have outlined the definitions of occupational hygiene components and dust-related parameters within this scope. In our subsequent article, we will address other measurement parameters.
Author: Hamdi YÜKSEL
All text and visual content on our website belong to the authors of www.novel.com.tr. No content on the website may be copied, modified, or utilised in other print or digital media (websites, blogs, magazines, books, etc.) without written permission. Our rights are protected under the provisions of the Law on Intellectual and Artistic Works No. 5846.
Note: All images used may be subject to copyright by their respective owners. Images fall under the “Creative Commons” (CC0) licence.
Frequently Asked Questions
Why is the topic of Occupational Safety and Environmental Measurement Parameters Air Quality Measurement Parameters and Measurement Methods important?
This article outlines fundamental concepts, intended use, and practical considerations regarding occupational safety and environmental measurement parameters, air quality parameters, and measurement methods, adopting NOVEL's technical editorial approach.
How should accurate measurement or product selection be conducted?
Measurement range, environmental conditions, target parameters, and application objectives must be evaluated collectively. Product or methodology selection should not be based solely on a single technical parameter.
Whom may I contact for technical support?
The NOVEL Technical Team provides engineering assistance with measurement methodologies, instrument selection, and application-specific equipment evaluation.